• 제목/요약/키워드: Storage flux

검색결과 159건 처리시간 0.025초

경수로 사용후핵연료 건식저장용기 간 중성자 표면선속 간섭률 평가 (Evaluation of Neutron Flux Accounting for Shadowing Effect Among the Dry Storage Casks)

  • 곽민우;이신동;김광표
    • 방사선산업학회지
    • /
    • 제18권2호
    • /
    • pp.133-140
    • /
    • 2024
  • The Korean 2nd basic plan for management of high-level radioactive waste presented a plan to manage spent nuclear fuel through dry storage facilities in NPP on-site. For the construction and operation of the facility, it is necessary to develop the monitoring system of the integrity of spent nuclear fuel before operation. NUREG-1536 recommends that the theoretical cask array, typically in the 2×10 array, should account for shadowing effect among the dry storage casks. The objective of this study was to evaluate neutron flux accounting for shadowing effect among dry storage casks. The neutron release rate was evaluated using ORIGEN based on the design basis fuel condition. And the simulation of dry storage casks and evaluation of the shadowing effect were performed using MCNP. Shadowing effect of other dry storage casks was the highest at the center of the dry storage facility of the 2×10 array compared with the outside of the cask. The shadowing effect of neutron flux on the surface among the metal casks was approximately 18% at point 1, 23% at point 2, and 43% at point 3. For the concrete casks, the shadowing effect of neutron flux on the surface was approximately 46% at point 1, 51% at point 2, and 52% at point 3. This means that correction is necessary to monitor the integrity of spent nuclear fuel in each dry storage cask through evaluation of shadowing effect. The results of this study will be used for comparative analysis of neutron measurement data from spent nuclear fuels in dry storage cask. Additionally, the neutron flux evaluation procedure used in this study could be used as the basic data of safety assessment of dry storage cask and development of safety guide.

기상 조건에 따른 도시 캐노피 모형의 성능 비교 (Performance Comparison of an Urban Canopy Model under Different Meteorological Conditions)

  • 유영희;백종진;이상현
    • 대기
    • /
    • 제22권4호
    • /
    • pp.429-436
    • /
    • 2012
  • The performances of the Seoul National University Urban Canopy Model (SNUUCM) under different meteorological conditions (clear, cloudy, and rainy conditions) in summertime are compared using observation dataset obtained at an urban site. The daily-averaged net radiation, sensible heat flux, and storage heat flux are largest in clear days and smallest in rainy days, but the daily-averaged latent heat flux is similar among clear, cloudy, and rainy days. That is, the ratio of latent heat flux to net radiation increases in order of clear, cloudy, and rainy conditions. In general, the performance of the SNUUCM is better in clear days than in cloudy or rainy days. However, the performance in simulating sensible heat flux in clear days is as poor as that in rainy days. For all the meteorological conditions, the performance in simulating latent heat flux is worst among the performances in simulating net radiation, sensible heat flux, and latent heat flux. The normalized mean error for latent heat flux is largest in rainy days in which the relative importance of latent heat flux in the surface energy balance becomes greatest among the three conditions. This study suggests that improvements to the parameterization of processes that are related to latent heat flux are particularly needed.

석유류 저장 탱크에서의 액면 및 유츌화재에 대한 복사열의 실험적 연구 (Experimental Study of Radiation Heat Flux for the Pool and Spill Fire in Petroleum Storage Tanks)

  • 김홍;박형주
    • 한국안전학회지
    • /
    • 제19권1호
    • /
    • pp.88-93
    • /
    • 2004
  • This experimental study was carried out to evaluate effect of the radiation heat flux for the pool and spill fire in petroleum storage tanks, which were made form steel. Each of them had the capacity of 250, 2500 and 25000 liter, respectively. The effects of the radiation heat flux are as follows; 1) The intensity of radiation heat flux from a flame decreased exponentially with increasing distance from outside wall of tanks, and increased significantly with surface area of tank and dyke. 2) In the case of 25000L tank, the radiation heat flux was about max. 98.9kW/$m^2$ in 1m from wall of tank. 3) The distance, that was able to ignite wood or plastics by radiation heat flux of approximately 12.5kW/$m^2$, was about 3.14m from wall of 25000L tank.

득량만의 열수지 계절 변동 (The Seasonal Variation of the Heat Budget in Deukryang Bay)

  • 주용환;조규대
    • 한국환경과학회지
    • /
    • 제7권1호
    • /
    • pp.67-73
    • /
    • 1998
  • Surface heat budget of the Deukryang Bay from July 1, 1992 to September 12, 1993 is analyzed by us- ing the meteorological data (by Changhung Observatory and Mokpo Meteorological Station) and oceanogaphical data (by Research Center for Ocean Industrial Development. Pukyong National University). Each flux element at the sea surface which has annual variation Is derived with application of an aerodynamical bulk method and empirical formulae. The solar radiation Is the maximum In spring and sensible heat are the maximum in autumn and water. and minimum in summer The heat .storage rate is calclilated by using the rate of water temperature variation according to the depth. The oceanic transport heat is estimated as a residual. The net heat flux, the heat storage rate are positive In spring and summer, while they are negative in autumn and winter. The oceanic transport heat Is convergence In winter and divergence In the rest of seasons.

  • PDF

낙동강 강정고령보의 여름철 열수지 일변화 - 열 저장량 변동을 중심으로 - (Daily Variation of Heat Budget Balance in the Gangjeong-Goryung Reservoir for Summertime - Concerning around the Rate of Heat Storage -)

  • 김성락;조창범;김해동
    • 한국환경과학회지
    • /
    • 제24권6호
    • /
    • pp.721-729
    • /
    • 2015
  • Surface heat balance of the Gangjeong-Goryung Reservoir is analyzed for 12-17 August 2013. Each flux elements at the water surface is derived from the special field observations with application of an aerodynamical bulk method for the turbulent heat fluxes and empirical formulae for the radiation heat fluxes. The rate of heat storage in the reservoir is estimated by using estimated by surface heating rate and the vertical water temperature data. The flux divergence of heat transport is estimated as a residual. The features of the surface heat balance are almost decided by the latent heat flux and the solar radiation flux. On average for 12-17 August 2014 in the Gangjeong- Goryung Reservoir, if one defines the insolation at the water surface as 100 %, 94 % is absorbed in the reservoir; thereafter the reservoir loses about 30~50% by sensible heat, latent heat and net long-wave radiation. The residue of 50~80 % raises the water temperature in the reservoir or transported away by the river flow during the daytime.

금속스크랩이 혼합된 상변화물질의 유효열전도율 (Effective thermal conductivity of the phase change material with metal scrap)

  • 김시범;노승탁
    • 대한기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.923-928
    • /
    • 1986
  • 본 논문에서는 열전도율이 큰 금속의 스크랩과 파라핀을 혼합한 축열 매질에 있어서 스크랩의 체적 혼합율에 따르는 열전도율의 변화를 모델링과 실험으로 구해서 축열 계산에 필요한 열전도율 자료를 제시하고자 한다.

우리나라 도심지에서의 저장열 산출에 관한 연구 (A Study on Retrieval of Storage Heat Flux in Urban Area)

  • 이다래;김홍희;이상현;이두일;홍진규;홍제우;이근민;이경상;서민지;한경수
    • 대한원격탐사학회지
    • /
    • 제34권2_1호
    • /
    • pp.301-306
    • /
    • 2018
  • 도시화는 여름철 도시형 홍수, 도시 열섬 등의 문제를 야기시킨다. 이러한 현상을 해결하기 위해서는 도시 열환경 변화의 정확한 파악이 필요하다. 이는 에너지 수지를 통해 설명될 수 있지만, 도심지의 경우 일반적인 에너지 수지와 달리 건물이나 인공토지피복에 의해 저장된 열에너지인 저장열을 고려하여야 한다. 하지만 저장열은 도시 표면의 복잡한 3차원 구조와 피복의 다양성 때문에 그 산출이 어려우며, 도시마다 다른 환경으로 인해 선행연구의 저장열 산출 방법을 타 도심지에 적용시키는 데는 어려움이 존재한다. 특히 대부분의 선행연구는 국외 도시를 중심으로 이루어졌기 때문에 국내 도심지의 다양한 토지피복과 건물 특성에 적합한 저장열 산출 연구가 필요하다. 따라서 본 연구에서는 국내 도심지의 다양한 지표타입이 존재하는 지역의 자료를 이용하여 저장열의 정량적인 산출이 가능한 회귀 식 도출을 목적으로 한다. 이를 위해 순복사와 지표면 온도 자료를 독립변수로, 플럭스 타워 기반 저장열 추정치를 종속변수로 사용하여 비선형 회귀분석을 수행하였으며, 산출된 회귀계수를 각 독립변수에 적용하여 저장열 산출 회귀 식을 도출하였다. 플럭스 타워 기반 저장열 추정치의 시계열 분석 결과 본 연구에서 산출한 저장열이 주간의 high peak와 야간에서의 값의 분포와 경향을 잘 모의하고 있었고, 플럭스 타워 기반 저장열 추정치에 비해 연속적인 저장열 산출이 가능하였다. 또한 산점도 분석 결과 Root Mean Square Error (RMSE) $50.14Wm^{-2}$, bias $-0.94Wm^{-2}$로 유의한 수준의 정확도를 보였다.

Numerical study on Comparison of Self-Pressurization Behavior of Liquid Nitrogen Cryostat for Umbilical Cord Blood Storage System Design

  • Mahfud, M.I.;Phil, K.E.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.409-414
    • /
    • 2009
  • Since cryogens are stored at very low temperatures, the cryogenic storage systems are quite sensitive to heat leaks. Even though the vessel operated under sealed condition with vacuum insulation and reflective coatings are used, the heat leakage into the vessel is still unavoidable. Therefore, this paper concerns with numerical study of self-pressurization used to analysis the optimum design with the variation volume fraction, effect of heat flux and storage pressure of liquid nitrogen. The result shows that as the volume fraction increases, the pressure rise reduces and the relatively at atmosphere pressure is better than the higher one. In addition, higher heat flux leads the pressure rise increases faster than low one. The additional of heat pipe system to reduce the pressure rise rate also has been done. By this comparison, the optimum design for storage umbilical cord blood can be selected.

  • PDF

LNG 저장 탱크의 Pool Fire에 의한 복사열 피해 (Radiation Damage by the Pool Fire of LNG Storage Tank)

  • 손정환;한윤봉
    • 한국가스학회지
    • /
    • 제2권1호
    • /
    • pp.14-22
    • /
    • 1998
  • 본 연구에서는 LNG 저장탱크에서 액면화재(pool fire) 발생시 복사열속(radiation flux)의 정량적인 예측과 복사열 피해를 줄이는 방법을 제안하기 위하여 RISC모델을 사용하여 여러 조건에서 복사열속을 계산하였다. 모델 예측결과 LNG 탱크의 액면화재에 의한 복사열 피해에 가장 큰 영향을 미치는 인자는 풍속임을 알 수 있었다. 화염과 피해 대상물사이의 복사피해 정도는 높은 풍속에서 보다 낮은 풍속에서의 풍속변화에 따라 크게 변하였다. 또한 액면화재 발생시 복사열 피해는 탱크 또는 공장 주위에 방풍시설을 함으로써 크게 줄일 수 있음을 알 수 있었다. 방풍시설은 다른 방법들 보다 경제적이기 때문에 냉각시설 및 소방시설과 연계하여 가스 저장탱크 주위에 설치하는 것이 바람직하다.

  • PDF

Modeling and Position-Sensorless Control of a Dual-Airgap Axial Flux Permanent Magnet Machine for Flywheel Energy Storage Systems

  • Nguyen, Trong Duy;Beng, Gilbert Foo Hock;Tseng, King-Jet;Vilathgamuwa, Don Mahinda;Zhang, Xinan
    • Journal of Power Electronics
    • /
    • 제12권5호
    • /
    • pp.758-768
    • /
    • 2012
  • This paper presents the modeling and position-sensorless vector control of a dual-airgap axial flux permanent magnet (AFPM) machine optimized for use in flywheel energy storage system (FESS) applications. The proposed AFPM machine has two sets of three-phase stator windings but requires only a single power converter to control both the electromagnetic torque and the axial levitation force. The proper controllability of the latter is crucial as it can be utilized to minimize the vertical bearing stress to improve the efficiency of the FESS. The method for controlling both the speed and axial displacement of the machine is discussed. An inherent speed sensorless observer is also proposed for speed estimation. The proposed observer eliminates the rotary encoder, which in turn reduces the overall weight and cost of the system while improving its reliability. The effectiveness of the proposed control scheme has been verified by simulations and experiments on a prototype machine.