• 제목/요약/키워드: Storage capacity

검색결과 2,114건 처리시간 0.026초

재고설비규모를 위한 최적분배 모델의 연구 (A Study on the Optimum Allocation Model for Inventory Capacity)

  • 최진영;정기호
    • 산업경영시스템학회지
    • /
    • 제5권6호
    • /
    • pp.1-6
    • /
    • 1982
  • The objective of this thesis to Provide a better insight into the effect of the amount of in-process storage has on the efficiency of production line with variable operation times. It is assumed that the material enters the line at the first work station and is then processed progressively through the line until it exits at the last work station, a finite amount of in-process storage is provided before all but the first work station of the line and the operation time of the work stations are statistically independent and follow exponential distribution. Under the above assumption, optimum allocation model is developed and following two approaches are used : 1) Given the available storage capacity, optimum allocation which minimizes the number of items in the line. 2) Given the available storage capacity, optimum allocation which. maximizes the utilization factor of the line. In a balanced three stage line, the production line efficiency is maximized under both categories when the second in-process storage is larger than the first.

  • PDF

댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(II) (Hydraulic & Hydrologic Design Criteria for an Emergency Drainage of Reservoir (II))

  • 이재응;손광익;강민석
    • 한국수자원학회논문집
    • /
    • 제48권3호
    • /
    • pp.159-167
    • /
    • 2015
  • 댐 운영에 있어서 저수지 초기 담수 시 또는 집중호우 등에 의한 급격한 수위 상승 방지나 운영 중에 댐체 점검 및 수리 또는 자연재해로 인한 위급한 상황 발생 등 저수지를 비워야 할 상황이 발생할 수 있으며, 이에 대한 대책으로 비상 시 방류할 계획 및 설비가 필요하다. 그러나 현재 국내에는 이러한 비상방류에 대한 기준이 미비한 실정이다. 본 연구에서는 댐 안정성 제고를 위해 유사시 저수지 저류량을 안전하게 배제시킬 수 있는 비상방류 설비를 저수지 모의 모형인 HEC-ResSim 모형을 이용하여 규모 및 배제일수에 대하여 모의하고 산정하였다. 저수지 규모에 따라 세 개의 댐에 대해 검토하였다. 대상댐은 저류용량을 기준으로 10억 $m^3$ 이상인 소양강댐과 1~10억 $m^3$ 댐으로 합천댐, 1억 $m^3$ 미만의 댐으로 대곡댐을 선정하여, 방류시설의 규모를 산정하고 배제일수를 모의하여 기준의 적정성과 적용 가능성에 대해 검토하였다.

저유수량의 소실률 조사연구 (A Study on Sediment Deposite in Reservoir)

  • 엄태영
    • 한국농공학회지
    • /
    • 제10권1호
    • /
    • pp.1413-1419
    • /
    • 1968
  • Yochon reservoir was consturcted with an original storage capacity of 202.7 chung-meters. This reservoir receives the water from watershed area of 933.0 chungbo and has irrigated area of 478.0 chungbo. In 1967 a detailed capacity survey of this reservoir was carried out by a new depth-recorder under the scheme of reservoir sedimentation of Agricultural Engineering Research Center. Significant findings are 1. The capacity of the reservoir for the water storage has been reduced by 8.9%(18.066 chung-meters out of the 202.7 chung-meters) since its construction, a period of just 39.0 years. 2. The sediment accumulation in the reservoir represents an average annual soil loss of 0.496mm depth(0.463 chung-meters) of soil from the watershed area of 933.0 chungbo. Eventually the capacity of the reservoir for the water storage will be reducing by about 25%(50.7 chung-meters out of the 202.7 chung-meters)in one hundred years since its construction. We have to set up controlling projects for those reservoir protections from the sediment, soil loss, and other failures. The depth recorder is very useful, convenient, and accurate machine for surveys of reservoir capacity and other river surveys.

  • PDF

Subclustering을 이용한 홀로그래픽 디지털 정보저장 시스템의 이진 데이터 에러 보정기 구현 (Design Error Corrector of Binary Data in Holographic Digital Data Storage System Using Subclustering)

  • 김상훈;김장현;양현석;박영필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.617-619
    • /
    • 2004
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time in. Today any data storage system can not satisfy these conditions, but holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System architecture without mechanical actuating part is possible, so fast data transfer rate and high storage capacity about $1Tb/cm^3$ can be realized. In this paper, to correct errors of binary data stored in holographic digital data storage system, find cluster centers using subtractive clustering and reduce intensities of pixels around centers, so the intensify profile of data rare will be uniform and the better data storage system can be realized.

  • PDF

Design and Comparison of Error Correctors Using Clustering in Holographic Data Storage System

  • Kim, Sang-Hoon;Kim, Jang-Hyun;Yang, Hyun-Seok;Park, Young-Pil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1076-1079
    • /
    • 2005
  • Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time in. Today any data storage system can not satisfy these conditions, but holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System architecture without mechanical actuating part is possible, so fast data transfer rate and high storage capacity about 1Tb/cm3 can be realized. In this paper, to correct errors of binary data stored in holographic digital data storage system, find cluster centers using clustering algorithm and reduce intensities of pixels around centers. We archive the procedure by two algorithms of C-mean and subtractive clustering, and compare the results of the two algorithms. By using proper clustering algorithm, the intensity profile of data page will be uniform and the better data storage system can be realized.

  • PDF

RDP: A storage-tier-aware Robust Data Placement strategy for Hadoop in a Cloud-based Heterogeneous Environment

  • Muhammad Faseeh Qureshi, Nawab;Shin, Dong Ryeol
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4063-4086
    • /
    • 2016
  • Cloud computing is a robust technology, which facilitate to resolve many parallel distributed computing issues in the modern Big Data environment. Hadoop is an ecosystem, which process large data-sets in distributed computing environment. The HDFS is a filesystem of Hadoop, which process data blocks to the cluster nodes. The data block placement has become a bottleneck to overall performance in a Hadoop cluster. The current placement policy assumes that, all Datanodes have equal computing capacity to process data blocks. This computing capacity includes availability of same storage media and same processing performances of a node. As a result, Hadoop cluster performance gets effected with unbalanced workloads, inefficient storage-tier, network traffic congestion and HDFS integrity issues. This paper proposes a storage-tier-aware Robust Data Placement (RDP) scheme, which systematically resolves unbalanced workloads, reduces network congestion to an optimal state, utilizes storage-tier in a useful manner and minimizes the HDFS integrity issues. The experimental results show that the proposed approach reduced unbalanced workload issue to 72%. Moreover, the presented approach resolve storage-tier compatibility problem to 81% by predicting storage for block jobs and improved overall data block placement by 78% through pre-calculated computing capacity allocations and execution of map files over respective Namenode and Datanodes.

곡률이 있는 벽면근처에서 고속회전하는 유연디스크의 거동 해석 (A Study on the Behavior of a Spinning Flexible Disk near a Curved Wall)

  • 이호렬;임윤철
    • 정보저장시스템학회논문집
    • /
    • 제2권3호
    • /
    • pp.201-207
    • /
    • 2006
  • Information storage devices have been studied to increase the storage capacity and the data transfer rate as well as to decrease the access time and their physical sizes. Optical information storage devices have been achieved high-capacity by reducing optical spot size remarkably due to the development of Blue-ray technology. Optical information storage devices usually use 1.2mm-thick polycarbonate(PC) media to get high enough stiffness. However, it would be better if we can decrease the thickness of a disk for achieving thinner device while keeping the capacity as large as possible. Decreasing the thickness of the storage media makes it difficult to read and write data because it increases the transverse vibration of the rotating disk due to the interaction with surrounding air and the vibration characteristics of thin flexible disk itself, Therefore, a special design based on the fluid mechanics is required to suppress the transverse vibration of the disk in non-contact manner so that the optical pickup can read/write data successfully. In this study, a curved wall is proposed as a stabilizer to suppress the transverse vibration of a $95{\mu}m$-thick PC disk. The characteristics of disk vibration due to a curved wall have been studied through numerical and experimental analysis from the fluid mechanics point of view. The proposed shapes are possible candidates as stabilizers to suppress the transverse vibration of a flexible disk which rotates at high speed.

  • PDF

마이크로그리드(MG)의 설계를 위한 에너지저장장치(ESS)의 최소용량산정 기법에 관한 연구 (A Study on the Method to Evaluate Minimum Capacity of Energy Storage System(ESS) for Micro-Grid Design)

  • 이재걸;신정훈;최영도;남수철;김태균
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.52-58
    • /
    • 2009
  • 본 논문에서는 마이크로그리드(Micro grid, MG)의 설계에서 필요로 되는 에너지저장장치(Energy storage system, ESS)의 최소설비용량을 산정할 수 있는 확률론적 방법론을 제시하였다. ESS기술은 아직까지 경제성 측면에서 매우 높은 설비비용이 필요로 되기 때문에 적정 설비규모를 산정하는 것과 MG의 안정적인 운영을 위해서 최소 설비용량에 대한 가이드라인의 제시가 필요로 된다. 본 논문에서 제시한 방법론은 Non-dispatchable 발전원 출력의 간헐성과 모든 발전기의 고장정지확률을 고려하여 MG가 자체적인 에너지 Self balancing을 유지할 수 있는 ESS의 최소설비용량을 산정할 수 있는 것을 특징으로 한다.

에너지저장장치와 결합한 WTG를 포함하는 전력계통의 Capacity Credit 평가 및 ESS 적정규모 평가방안 (Capacity Credit and Reasonable ESS Evaluation of Power System Including WTG combined with Battery Energy Storage System)

  • 오웅진;이연찬;최재석;임진택
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.923-933
    • /
    • 2016
  • This paper proposes a new method for evaluating Effective Load Carrying Capability(ELCC) and capacity credit(C.C.) of power system including Wind Turbine Generator(WTG) combined with Battery Energy Storage System(BESS). WTG can only generate electricity power when the fuel(wind) is available. Because of fluctuation of wind speed, WTG generates intermittent power. In view point of reliability of power system, intermittent power of WTG is similar with probabilistic characteristics based on power on-off due to mechanical availability of conventional generator. Therefore, high penetration of WTG will occur difficulties in power operation. The high penetration of numerous and large capacity WTG can make risk to power system adequacy, quality and stability. Therefore, the penetration of WTG is limited in the world. In recent, it is expected that BESS installed at wind farms may smooth the wind power fluctuation. This study develops a new method to assess how much is penetration of WTG able to extended when Wind Turbine Generator(WTG) is combined with Battery Energy Storage System(BESS). In this paper, the assessment equation of capacity credit of WTG combined with BESS is formulated newly. The simulation program, is called GNRL_ESS, is developed in this study. This paper demonstrates a various case studies of ELCC and capacity credit(C.C.) of power system containing WTG combined with BESS using model system as similar as Jeju island power system. The case studies demonstrate that not only reasonable BESS capacity for a WTG but also permissible penetration percent of WTG combined with BESS and reasonable WTG capacity for a BESS can be decided.

바다방석고둥육의 동결저장중 단백질조성과 근육조직의 변화 (Changes of Protein Composition and Muscle Tissues in Top Shell Meat during Frozen Storage)

  • 송대진;김창용;박환준
    • 한국식품영양과학회지
    • /
    • 제22권6호
    • /
    • pp.763-770
    • /
    • 1993
  • To investigate the quality changes during frozen storage, top shell, Omphalius pfeifferi capenteri, was stored at -18$^{\circ}C$, -$25^{\circ}C$ and -3$0^{\circ}C$ immediately after shelling and water holding capacity, protein composition and histological features were examined with the lapsed period of the storage. During the storage period, amount of free drip was increased with higher frozen temperature and longer frozen period, but with the longer storage period, the lower water holding capacity was observed. The extractability and composition of muscle protein, sarcoplasmic protein and stroma protein were rather stable regardless of frozen temperature and frozen storage period. However, the extractability of myofibrillar protein was decreased with higher frozen temperature and longer frozen storage period. On the changes of muscle tissue structure, following points were observed. 1) In the muscle tissue structure of fresh sample, fine muscle fiber was closely distributed all over the tissue regardless of cross and longitudinal section. 2) In tissue structure under frozen state, it was observed that ice crystals apparently grew with the higher storage temperature. Empty spaces between muscle bundles which wee formed by aggregations of muscle fiber were observed after 3 months storage at -18$^{\circ}C$ . 3) Tissue structure in thawed state was restored satisfactorily after 1 month storage regardless of storage temperature. After 3 months storage at -3$0^{\circ}C$, muscle tissue was well restored, but at -18$^{\circ}C$, empty spaces were apparent due to incomplete restoration.

  • PDF