• Title/Summary/Keyword: Storage capacity

Search Result 2,122, Processing Time 0.032 seconds

Optimal Sizing of In-Plant and Leased Storage Spaces under a Randomized Storage Policy (임의 저장방식 하에서 기업 내 저장공간과 외부의 임차공간에 대한 최적 규모 결정)

  • Lee, Moon-Kyu
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.4
    • /
    • pp.294-300
    • /
    • 2004
  • This paper considers a trade-off effect between in-house storage space and leased storage space in generic warehouses operated under a randomized storage assignment policy. The amount of in-house storage space is determined based on the law of large numbers satisfying a given service level of protection against space shortages. Excess space requirement is assumed to be met via leased storage space. A new analytic model is formulated for determining the excess space such that the total cost of storage space is minimized. Finally, computational results are provided for the systems where the standard economic-order-quantity inventory model is used for all items.

Novel methods of increasing the storage volume at Pumped Storage Power plants

  • Storli, Pal-Tore
    • International Journal of Fluid Machinery and Systems
    • /
    • v.10 no.3
    • /
    • pp.209-217
    • /
    • 2017
  • The paper presents two novel concepts of increasing the energy storage capacity at pumped storage power plants, both existing and new projects. The concepts utilize compressed air as a working medium to displace water from a volume originally not available for storage. The concepts are likely to give additional storage volume at a low cost, however, much development and many investigations are needed before the concepts can be shown to be technical and economical feasible solutions for energy storage. The concepts are disclosed so that researchers and utilities can start those investigations, hopefully helping the green transition by providing highly valuable energy storage for a future renewable energy having a much higher share of renewable energies than the current systems.

A Study on the DSM Effect of a Refrigerant-Subcooling Refrigeration System with an Ice Storage Tank (축열조를 이용한 냉매과냉각 시스템의 전력수요관리 효과에 대한 연구)

  • Kim, Jeong-bae;Lee, Eun-Ji;Lee, Dong-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.845-851
    • /
    • 2010
  • This study was experimentally performed to find the effects of refrigerant subcooling in the refrigeration system and to propose how to get the efficient use of energy. A refrigerant-subcooling refrigeration system consisted of a typical single vapor-compression refrigeration cycle, a subcooler, and an ice storage tank. The degree of subcooling at the exit of the condenser can be increased by the heat transfer between the subcooler and the ice storage tank. The cold heat in the ice storage tank was stored by using the refrigeration cycle during night time and then used to absorb the heat from the subcooler during daytime. The cooling capacity and COP of this system were higher than those of the conventional system due to the increase in the degree of subcooling. Typically, the refrigerant-subcooling system showed superior performance to the conventional refrigeration system and would also contribute to load leveling.

Development of New Effectiveness Assessment Indices of Pumped Storage Power Plant (양수발전기의 신 효용성 평가 지수 개발)

  • Lee, Sung-Hun;Choi, Jae-Seok;Cha, Jun-Min;Kim, Daniel
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.867-874
    • /
    • 2014
  • The pumped storage power plants have excellent load following characteristics. It can also be committed quickly for synchronous reserve when it is in the generating mode because it can readily increase its generating power and, consequently, increases the overall system reliability. There are strong incentives for standing the system reliability. Additionally, $CO_2$ emission can be typically impacted due to operation of pumped generators. The increase or decrease of $CO_2$ depends on the generation mix. This paper proposes evaluation of reliability, economy and environment of power system considering pumped generator. This paper describes three case studies of the reliability and economy and environment according to capacity factor and storage capacity of pumped generators. The probabilistic production simulation model is used in this paper. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model on the $5^{th}$ power plan in Korea.

Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System (EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터)

  • Seo, Young-Min;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

Study on Performance of Heat Pump using a subcooled refrigerant (냉매과냉각에 의한 열펌프의 성능향상에 관한 연구)

  • 박승준
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.159-164
    • /
    • 2000
  • In this paper a new type refrigerant liquid subcooling system which adopts ice storage system is proposed. And the cycle characteristicso of a new system was investigated. Since this system subcools a refrigerant in the daytime using the ice storaged by electric power in the night it is high efficiency heat pump system which have the merit of ice storage system and possible to improve the performance of the heat pump. The running to storage the ie was carried out for 10 hours in the night and th evaporating temperature was set on $-5^{\circ}C.$ Subcooling operation stayed as 430^{\circ}C$ subcooling degree and perfomed till the water in the IST(Ice storage tank) was reached $12^{\circ}C$. The experimental result showed that a new system was superior to the existing refrigeration system generally. The total cooling capacity of a new system was about 11% higher than that of the existing refrigeration system. And the COP of a new system was improved by 22% compared to the existing refrigeration system.

  • PDF

Behavior Analysis and Empirical Relation for a Flexible Disk with High Speed Rotation (고속회전 유연디스크의 거동해석과 경험식)

  • Lee, Ho-Ryul;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.245-250
    • /
    • 2006
  • Organizations such as broadcasting stations and libraries which deal with huge amount of information require high-capacity storage systems for archiving their materials and information. It is necessary and urgent for the storage people to develop a compact, high capacity, and low-cost data storage systems. Even though the Blue-ray technology is commercialized and now it is on the market, demand for the compact and low-cost system is still increasing. A flexible disk system has been introduced recently to satisfy above mentioned requirements. The system uses multiple of thin disks and is expected to achieve technical requirements. However, decreasing the disk thickness makes it difficult to read and write data because it decreases the disk rigidity so that the transverse vibration of the rotating disk increases easily due to both the interaction with surrounding air and the vibration characteristics of thin flexible disk itself. In this study, flat-type stabilizer is proposed to suppress the transverse vibration of a $95{\mu}m$-thick polycarbonate disk. Characteristics of disk vibration have been studied through the results of numerical analysis from the fluid mechanics point of view. Numerical simulation is verified through the experiment by measuring the gap between the rotating disk and the stationary flat stabilizer. The axial deflections of the disk are computed for various rotating speeds and reference gap sizes and then a method of regression is applied to those data. As a result, an empirical relation is proposed for the steady deformation shape of the rotating disk.

  • PDF

Design and analysis of slider and suspension in 4${\times}$l near-field probe array

  • Hong Eo-Jin;Oh Woo-Seok;Jung Min-Su;Park No-Cheol;Yang Hyun-Seok;Park Young-Pil;Lee Sung-Q;Park Kang-Ho
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.47-52
    • /
    • 2005
  • A lot of information storage devices have been introduced and developed for recently years. The trends of those devices are high capacity, compact size, low power consumption, reliability, and removability for data interchange with other device. As a satisfaction of these trends, near-field technique is in the spotlight as the next generation device. In order for a near-field recording to be successfully implemented in the storage device, a slider and suspension is introduced as actuating mechanism. The optical slider is designed considering near-filed optics. Suspension is not only supports slider performance, and tracking servo capacity but also meets the optical characteristics such as tilt aberration, and guarantee to satisfy shock performances for the mobility fir the actuator. In this study, the optical slider and the suspension for near-field probe array are designed and analyzed considering dynamic performance of head-gimbal assembly and shock simulation..

  • PDF

The Hydrogen Storage Characteristics of Ti-Zr-Cr-V Alloys (Ti-Zr-Cr-V 합금의 수소저장 특성)

  • Cho, Sung-Wook;Han, Chang-Suck;Park, Choong-Nyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.9 no.3
    • /
    • pp.101-110
    • /
    • 1998
  • The change of hydrogen storage characteristics by substituting zirconium for a portion of titanium in Ti-Cr-V alloys has been studied. The zirconium substitution decreased the plateau pressure and hysteresis of the PC isotherm. However, it decreased the hydrogen storage capacity and increased slopping in PC isotherm by forming $Cr_2Zr$ phase. By modifying the composition ratio of titanium to chromium, thereby suppressing the formation of $Cr_2Zr$ phase, we got an alloy having very high hydrogen storage capacity. The heat treatment of the alloys improved the flatness of plateau very much without a decrease in the maximum and the effective hydrogen storage capacities.

  • PDF

Economics of Self-Generation by Natural Gas Industry Using the Mixed Integer Program (혼합정수계획법을 이용한 천연가스(LNG) 산업의 자가발전소 건설에 대한 경제성 분석)

  • Lee, Jeong-Dong;Byun, Sang-Kyu;Kim, Tai-Yoo
    • IE interfaces
    • /
    • v.13 no.4
    • /
    • pp.658-667
    • /
    • 2000
  • Seasonal variation of natural gas demand coupled with rigid and stable import pattern of gas represents the characteristic feature of the Korean Liquified Natural Gas(LNG) industry. This attribute has required a huge amount of investment for the construction of storage facility. Thus, to minimize the supply cost, it is legitimate to reduce storage requirement itself. In this study, we combine three alternative methods to deal with the storage requirement to minimize the supply cost. Those are (1) adding additional storage tanks, (2) inducing large firm customers, and (3) constructing gas-turbine self generation facilities. Methodologically, we employ the mixed integer program (MIP) to optimize the system. The model also consider demand and price-setting scheme in separate modules. From the results, it is shown that if alternatives are combined optimally, a number of storage tanks can be reduced substantially compared with the original capacity plan set by the industry authorities. We perform various sensitivity analyses to check the robustness of the results. The methodology presented in this study can be applied to the other physical network industry, such as hydraulics. The empirical results will shed some light on the rationalization of capacity planning of the Korean natural gas industry.

  • PDF