• 제목/요약/키워드: Storage Air Heater

검색결과 40건 처리시간 0.028초

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

빙축열 시스템과 흡수식 냉온수기 공조 방식의 경제성 분석 (An Economic Analysis of Ice Thermal Storage and Absorption Chiller-Heater Systems)

  • 임현우;김영일;김강산;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.218-223
    • /
    • 2009
  • Cost related to building equipment accounts for about 85% of the life cycle cost of buildings. Therefore proper selection of air-conditioning system is important for reducing the overall cost of buildings. In this study, large capacity ice thermal storage and absorption chiller-heater for air-conditioning a building with a floor area of $9,900\;m^2$ are compared economically. For easy input and analysis, an Ms Excel VBA program has been developed. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. Under the assumptions made in this study, overall cost of an absorption chiller-heater is less than that of an ice thermal storage, but this is not absolute and different outcome may result if different assumptions are made. This study is useful for those who are interested in choosing an economical air-conditioning system for large-size buildings with simple calculations.

  • PDF

열펌프 열풍건조기를 이용한 표고버섯의 건조 품질특성 (Drying Quality Characteristics of Shiitake Mushroom by Heat Pump Hot-air Dryer)

  • 신은정;이호준
    • 한국지열·수열에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.22-27
    • /
    • 2015
  • Quality characteristics of Shiitake mushroom using two types of dryers, energy-efficient heat pump hot-air dryer and electric heater hot-air dryer were compared. Energy consumed during drying by heat pump hot-air dryer and electric heater hot-air dryer were 22.8 kWh and 28.9 kWh, respectively. Total polyphenol content of heat pump hot-air dryer and electric heater hot-air dryer after drying were $290.55{\pm}10.56ppm$ and $192.99{\pm}6.53ppm$, respectively. No differences were observed between dryers in reconstitution rate and browning ratio after drying. Also, there were no differences between dryers in color value and ${\Delta}E$ value after drying. Shiitake mushroom drying at $45^{\circ}C$ by heat pump hot-air dryer was proved to be more efficient in energy consumption than by electric heater hot-air dryer.

태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구 (Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted)

  • 이진국;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

열펌프 온수기의 부하 대응 축열조 제어에 관한 연구 (A Study on Control Method of Thermal Storage Tank for Varying Thermal Load in Heat Pump Water Heater)

  • 남현규;배철호
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.330-335
    • /
    • 2012
  • A characteristic behavior of the thermal storage tank for varying thermal load in heat pump water heater was studied. The control method was suggested and applied. By measuring the temperature within the storage tank, the heat pump was ON/OFF controlled. The appropriate measuring position and the size of heat exchanger gives the minimized power consumption of heat pump. As the length of heat exchanger increases, the temperature measuring position goes down of the storage tank and the power consumption increases.

저온창고에서 냉동기 응축폐열을 이용한 제상시스템 성능평가 (Performance Evaluation of a Defrosting System Using the Condensation Heat of a Refrigerator in Cold Storage)

  • 박천완;이동규;임관빈;강채동
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.72-78
    • /
    • 2014
  • In a cold chain, the refrigerator is also employed for defrosting, by using an electric heater, which consumes 15% of the power for the system operation. In this study, the condensation heat of the refrigerant was suggested as the heat source of defrosting heat, instead of that from an electric defrost heater. The heat for defrosting was stored to a phase change material (PCM, NMP : $52^{\circ}C$) in thermal storage, and was periodically supplied to the evaporator by a circulation loop of brine. As a result, a defrost time by the PCM was obtained that was less than or equal to that by the electric heater. Moreover, power consumption during defrosting was saved by up to 99% of that of the electric heater.

축열식 가열기형 풍동을 이용한 스크램제트 엔진 흡입구 실험연구 (Experimental Study of a Scramjet Engine Intake in a Storage Heater Type Hypersonic Wind Tunnel)

  • 강상훈;이양지;양수석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.463-466
    • /
    • 2010
  • 축열식 가열기 형태의 초음속 풍동을 이용하여 스크램제트 엔진 흡입구의 성능 연구를 수행하였다. 본 시험모델은 측벽배치변화가 성능에 큰 영향을 미치지 않는 것으로 나타났다. 격리부 성능연구에서는 Oblique shock train과 Normal shock train의 압력분포를 확인할 수 있었으며, 격리부의 불시동 한계성능을 분석하였다.

  • PDF

고온 공기 가열기 개발 현황 조사 및 고찰 (The Review and Investigation of High Temperature Heater Development)

  • 김정우;이정민
    • 한국추진공학회지
    • /
    • 제20권5호
    • /
    • pp.90-98
    • /
    • 2016
  • 극초음속 공기 흡입 추진기관의 지상 시험 시 추진기관의 고속 비행 조건을 모의하기 위해 고온 공기를 공급할 수 있는 고온 공기 가열기가 필요하다. 본 논문에서는 다양한 고온 가열기들을 조사하여 유형별로 정리하고, 장단점을 비교하였다. 가열기는 크게 유동장 내 연소 가열기, 아크 가열기, 축열식 가열기, 열교환식 가열기 4종류로 분류할 수 있었으며, 각각의 장단점이 다양하므로 목적에 맞게 가열기를 선정하여야 한다.

심야전기보일러 대체 Heat Pump의 경제성 분석 (Analysis on Economic Feasibility of Electric Night Storage Heat Pump as a Substitution of a Heater)

  • 정훈;조종영;이철희
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.119-124
    • /
    • 2011
  • Electric night storage heater was introduced and disseminated for power grid balancing and efficient management of power generation facility. But fuel cost for heating has been increased rapidly while the cost of electricity increased slightly. This abnormal rate system caused peak load in winter at last. To solve this problem, application of an air source heat pump was suggested. In the study, the effect of replacing night heater by heat pump and the economics were analysed. In addition the expectation of prospect of heat pump penetration was simulated based on surveyed and investigated data. As a result, fund supporting as well as institutional backing was needed for effective propagation and return of investment.

축열식 가열기의 설계 및 제작 (Design and Manufacture of Storage Air Heater)

  • 이양지;강상훈;박부민;양수석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.43-46
    • /
    • 2006
  • 축열식 가열기는 주로 초음속 지상추진 시험설비의 고고도 조건 모사를 위하여 구축되는 장비로 이외에도 로켓 엔진 노즐의 추력 보정시험, 가스터빈 엔진 연소기 모사시험에 범용으로 사용할 수 있다. 한국항공우주연구원에서 보유하고 있는 축열식 가열시스템은 마하 $2{\sim}5$, 고도 $0{\sim}25km$의 범위에서 구동하는 초음속 지상추진시험설비의 전온도 모사를 목적으로 설계되었으며, 최고 모사 온도 1,300 K, 최고 가압압력 3.5 MPa의 성능을 낸다. 본 논문에는 본 원에서 구축한 축열식 가열기의 목표로 한 일본 JAXA RJTF에 구축되어있는 축열식 가열기에 대하여 정리하도록 한다.

  • PDF