• Title/Summary/Keyword: Stone column method

Search Result 61, Processing Time 0.03 seconds

Evaluation of monotonic and cyclic behaviour of geotextile encased stone columns

  • Ardakani, Alireza;Gholampoor, Naeem;Bayat, Mahdi;Bayat, Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.65 no.1
    • /
    • pp.81-89
    • /
    • 2018
  • Stone column installation is a convenient method for improvement of soft ground. In very soft clays, in order to increase the lateral confinement of the stone columns, encasing the columns with high stiffness and creep resistant geosynthetics has proved to be a successful solution. This paper presents the results of three dimensional finite element analyses for evaluating improvement in behaviour of ordinary stone columns (OSCs) installed in soft clay by geotextile encasement under monotonic and cyclic loading by a comprehensive parametric study. The parameters include length and stiffness of encasement, types of stone columns (floating and end bearing), frictional angle and elastic modulus of stone column's material and diameter of stone columns. The results indicate that increasing the stiffness of encasement clearly enhances cyclic behaviour of geotextile encased stone columns (GESCs) in terms of reduction in residual settlement. Performance of GESCs is less sensitive to internal friction angle and elasticity modulus of column's materials in comparison with OSCs. Also, encasing at the top portion of stone column up to triple the diameter of column is found to be adequate in improving its residual settlement and at all loading cycles, end bearing columns provide much higher resistance than floating columns.

Influence of dual layer confinement on lateral load capacity of stone columns: An experimental investigation

  • Akash Jaiswal;Rakesh Kumar
    • Geomechanics and Engineering
    • /
    • v.32 no.6
    • /
    • pp.567-581
    • /
    • 2023
  • Enhanced vertical load capacity of the ground reinforced with the stone columns drew great attention by the researchers as it deals with many of the geotechnical difficulties associated with the weak ground. Recently, it has been found that the stone columns are also prone to fail under the shear load when employed beneath the embankments or the foundations susceptible to lateral loads. In this study, the effect of various encasement conditions on the lateral deflection of stone columns is investigated. A method of dual layers of encasement has been introduced and its the effect on lateral load capacity of the stone columns has been compared with those of the single encased stone column and the un-encased stone columns. Large shear box tests were utilised to generate the shear deformation on the soil system under various normal pressure conditions. The stiffness of the soil-stone column combined system has been compared for various cases of encasement conditions with different diameters. When subjected to lateral deformation, the encased columns outperformed the un-encased stone columns installed in loose sand. Shear stress resistance is up to 1.7 times greater in dual-layered, encased columns than in unencased columns. Similarly, the secant modulus increases as the condition changes from an unencased stone column to single-layer encasement and then to dual-layer encasement, indicating an improvement in the overall soil-stone column system.

Load Carrying Capacity and Failure Mechanism of Geogrid Reinforced Stone Columns : Reduced-Scale Model Tests (지오그리드 보강 Stone Column의 파괴메카니즘 및 지지력 특성 - 축소모형실험을 통한 고찰)

  • Lee, Dae-Young;Song, Ah-Ran;Yoo, Chung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.121-129
    • /
    • 2006
  • Stone column is one of the ground improvement systems which is being used for accelerating consolidation and increasing bearing capacity for settlement sensitive structures like load embankments, bridge abutments, oil storage tanks etc. The effects of this method are enhancement of ground bearing capacity, reduction of settlement, prevention of liquefaction and prevention of lateral ground movement. Recently, geosynthetic reinforced (encased) stone column approach has been developed to improve its load carrying capacity through increasing confinement effect. Although such a concept has successfully been applied in practice, fundamentals of the method have not been fully explored. This paper presents the results of an investigation on the bearing capacity and failure mechanism of geogrid-encased stone column by model tests. The results of the analyses indicated improved bearing capacity of the geogrid reinforced stone column method over the conventional strone column method with no encasing.

Optimal design of stone columns reinforced soft clay foundation considering design robustness

  • Yu, Yang;Wang, Zhu;Sun, HongYue
    • Geomechanics and Engineering
    • /
    • v.22 no.4
    • /
    • pp.305-318
    • /
    • 2020
  • Stone columns are widely used to treat soft clay ground. Optimizing the design of stone columns based on cost-effectiveness is always an attractive subject in the practice of ground treatment. In this paper, the design of stone columns is optimized using the concept of robust geotechnical design. Standard deviation of failure probability, which is a system response of concern of the stone column-reinforced foundation, is used as a measure of the design robustness due to the uncertainty in the coefficient of variation (COV) of the noise factors in practice. The failure probability of a stone column-reinforced foundation can be readily determined using Monte Carlo simulation (MCS) based on the settlements of the stone column-reinforced foundation, which are evaluated by a deterministic method. A framework based on the concept of robust geotechnical design is proposed for determining the most preferred design of stone columns considering multiple objectives including safety, cost and design robustness. This framework is illustrated with an example, a stone column-reinforced foundation under embankment loading. Based on the outcome of this study, the most preferred design of stone columns is obtained.

A Study on Applicability of the Calculation Method for Settlement of Stone Column (쇄석말뚝의 침하량 산정방법 적용성에 관한 연구)

  • Han, Sangsoo;Jung, Suntae;Lee, Jinhyung;Kim, Bokyoung;Kim, Kyungmin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.3
    • /
    • pp.5-12
    • /
    • 2016
  • Stone column is the method that replace soft ground such as weak clay and loose sand with gravel or crushed stone which has relatively high stiffness and low compressive. Stone column increases bearing capacity of the soft ground, reduces settlement, produces ground improvement effect by consolidation drain, and is effective to prevent soil liquefaction in sandy ground during an earthquake. Stone column has been used in many civil works, and has recorded quite a lot of construction achievement internationally, but there is no standardized settlement calculation method yet. Therefore, in this study, the applicability of the existing theoretical equations were evaluated through comparison and analysis to predict a reasonable settlement of the Stone column. Consequently, Hook's law formula was verified to be the most close to numerical analysis.

Logging for Diametric Variation of Granular Compaction Pile Using Crosshole Seismic Tests (크로스홀 탄성파 시험을 이용한 쇄석다짐말뚝의 시공직경 검측)

  • Park, Chul-Soo;Jung, Jae-Woo;Kim, Hak-Sung;Kim, Eun-Jung;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1415-1426
    • /
    • 2008
  • Stone columns, locally called "GCP (granular compaction pile)" can be used to improve strength and resistance against lateral movement of a foundation soil like rigid piles and piers. Also installation of such a discrete column facilitates drainage, and densifies and reinforces the soil in the sense of ground improvement. The integrity of the GCP has been indirectly controlled with the records of each batch including depth and the quantity of stone filled. An integrity testing was attempted using crosshole S-wave logging. The method is conceptionally same as the crosshole sonic logging (CSL) for drilled piers. The only and critical difference is that S-wave should be used in the logging, because P-wave velocity of the stone column is less than that of ground water. The crosshole sonic logger does not have the capability to measure S-wave propagating through the skeleton of crushed stone. An electro-mechanical source, which can generate either P- or SH-waves, and a 1-D geophone were used to measure SH-waves. Two 76mm diameter cased boreholes were installed 1 meter apart across the nominal 700mm diameter stone column. At every 10cm of depth, shear wave was measured across the stone column. One more borehole was also installed 1 meter outward from the one of the above boreholes to measure the shear wave profile of the surrounding soil. The diametric variation of the stone column with respect to depth was evaluated from the shear wave arrival times across the stone column, and shear wave velocities of crushed stone and surrounding soil. The volume calculated with these variational diameters is very close to the actual quantity of the stone filled.

  • PDF

PRACTICAL MODELLING OF STONE-COLUMN REINFORCED GROUND

  • Tan By S.A.;Tjahyono S.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.291-311
    • /
    • 2006
  • The acceleration of consolidation by stone columns was mostly analysed within the framework of a basic unit cell model (i.e. a cylindrical soil body around a column). A method of converting the axisymmetric unit cell into the equivalent plane-strain model would be required for two-dimensional numerical modelling of multi-column field applications. This paper proposes two practical simplified conversion methods to obtain the equivalent plane-strain model of the unit cell, and investigates their applicability to multi-column reinforced ground. In the first conversion method, the soil permeability is matched according to an analytical equation, whereas in the second method, the column width is matched based on the equivalence of column area. The validity of these methods is tested by comparison with the numerical results of unit-cell simulations and with the field data from an embankment case history. The results show that for the case of linear-elastic material modelling, both methods produce reasonably accurate long-term consolidation settlements, whereas for the case of elasto-plastic material modelling, the second method is preferable as the first one gives erroneously lower long-term settlements, where plastic yielding of stone column are ignored.

  • PDF

A study on characteristics of composition method of inner foundation in stone stupa (석탑 기단부 적심구성방법에 대한 특성 고찰 - $7{\sim}8$세기 석탑 중 해체 수리한 석탑을 중심으로 -)

  • Chung, Hae-Doo;Jang, Suk-Ha
    • Journal of architectural history
    • /
    • v.16 no.5
    • /
    • pp.55-66
    • /
    • 2007
  • Through analysing on construction cases of stupa built in A.D. 7,8th, I have researched about these : constructive methods of inner soil of stupa, spatial compositions, characteristics of structures, arrangements of inner soil and etc. And cases analysed are six ; Mireuksajiseoktap(stone pagoda of Mireuksa Temple site), Gameunsajisamcheumgseoktap(three storied stone pagoda of Gameunsa Temple site), Goseonsajisamcheungseoktap(three storied stone pagoda of Goseonsa Temple site), Wolseong nawolliocheungseoktap(five storied stone pagoda in Nawonri, Wolseong), Guksagokseoktap(three storied stone pagoda in Guksa valley), Giamgokseoktap(three storied stone pagoda in Giam valley). Additionally we researched about inner soil of Sacheonwangsaji tapji(basement of stone stupa site in Sacheonwang Temple site) to speculate on composition of Synthetically, the foundation could be divided as core space and outer space. ; the former as structural function and the latter as ornamental function. And the core area could be divided again as center column space and buffer space. The relationship between core spaces and its formation are as belows; First, according to the area of foundation and scale of stone pagoda, formations of core are differed. As the scale of stone pagoda goes bigger, and the area of foundation goes larger, the structure of stone pagoda comprised by center column type and layered-core which endure upper load independently. On the contrary, as the scale of stone pagoda goes smaller, and the area of foundation goes lesser, the structure of stone pagoda tend to use only center column to endure upper part. Second, spatial composition of core area is comprised as two spaces, one which endure upper load and buffer space which absorb side pressure and upper pressure. The buffer space tend to be used in case of those structures which could not endure side pressure or have lots of joint. In some cases, it was located below the cover stone of foundation and gained upper load. And in case that have not gained pressure from side stone, the buffer space are comprised by smalle stone or roof tile to get structural supplement.

  • PDF

Comparison of Ultimate Bearing Capacity Formulas for Single Stone column in Bulging and General shear failure using in-situ test results (현장 시험치를 이용한 단일 쇄석다짐말뚝의 Bulging 및 General Shear Failure시의 극한지지력 제안식에 관한 비교 연구)

  • Chun, Byung-Sik;Kim, Won-Cheul;Seo, Deok-Dong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.2
    • /
    • pp.65-76
    • /
    • 2003
  • Stone column is a soil improvement method and can be applicable for loose sand or weak cohesive soil. Since the lack of sand, stone column seems one of the most adaptable approach for poor ground as a soil improvement technique. However, this method was not studied for practical application. In this paper, the bearing capacity of single stone column at the Gaduk, Ulsan and Gwangyang under the bulging and general shear failure mode were compared with those of the suggested formulas. Especially, a test result of single stone column at the Busan area by static load was compared with the bearing capacity of suggested formulas. The analysis results showed that there were not much bearing capacity differences among those suggested bearing capacity formulas. However, the bearing capacity by static load test was almost double of those with suggested formula. The result also showed that the undrained shear strength was the most important parameter for the bearing capacity estimation of stone column.

  • PDF

Comparative Study on the Prediction Method of Bearing Capacity for Single Stone Column (단일 쇄석다짐말뚝의 지지력 예측방법에 대한 비교 연구)

  • Chun, Byung-Sik;Kim, Won-Cheul;Jo, Yang-Woon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.1
    • /
    • pp.55-64
    • /
    • 2004
  • Stone column is a soil improvement method and can be applicable for loose sand or weak cohesive soil. Since the lack of sand in korea, stone column seems one of the most adaptable approach for poor ground as a soil improvement technique. However, this method was not studied for practical application. In this paper, the most affective design parameters for the bearing capacity of stone column were studied. The parametric study of major design factors for single stone column was carried out under the bulging and general shear failure condition, respectively. Especially, a test result of single stone column by static load was compared with the bearing capacity values of suggested formulas. The analysis result showed that the ultimate bearing capacity by the formula was much less than the measured value by the static load test. Especially, the result of the parametric study under general shear failure condition showed that the bearing capacity has big difference between each suggested formulas with the variation of the major design parameters. Therefore, the result of this study can be appliable for the future stone column project.

  • PDF