• 제목/요약/키워드: Stirling 냉동기

검색결과 46건 처리시간 0.02초

열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (I) : 성능시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (II) : Performance test)

  • 박성제;홍용주;김효봉;김양훈;이성래;이기백;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the cooling capacity / applied input power and cool down time are investigated. This cooler delivers approximately 0.9W cooling at 80K for 30W ~ 40W of input power. And, It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

회전하는 맥동관 냉동기의 맥동관에 대한 2차원 모델 해석 (Two-dimensional model analysis for the pulse tube of rotating pulse tube refrigerator)

  • 최재영;정상권;정은수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권3호
    • /
    • pp.63-69
    • /
    • 2006
  • This paper describes the effect of rotating frequency on the pulse tube of Stirling type pulse tube refrigerator. Various conditions were analyzed by two-dimensional analysis with several dominant non-dimensional parameters. With the additional pressure term influenced by centrifugal force in rotating condition, the linearized conservation equations of mass, momentum, energy of the gas were solved to obtain the first order variables and calculate the enthalpy flow in rectangular coordinates. The rotational effect in pulse tube for the refrigerator's performance were quantitatively evaluated. According to the first order analysis, the enthalpy flow decreases with the rotating speed.

공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계 (The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner)

  • 홍용주;박성제;김효봉
    • 연구논문집
    • /
    • 통권34호
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

MIRIS 지구관측 적외선카메라 인증모델 성능 시험 및 Field Test

  • 문봉곤;박영식;이창희;박성준;차상목;이대희;정웅섭;남욱원;박장현;육인수;가능현;이미현;이덕행;양순철;김영주;이기훈;정한;이승우;한원용
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2009년도 한국우주과학회보 제18권2호
    • /
    • pp.45.1-45.1
    • /
    • 2009
  • 과학기술위성 3호의 주탑재체인 MIRIS (Multi-purpose InfraRed Imaging System)는 우주관측카메라 (Space Observation Camera, SOC)와 지구관측카메라 (Earth Observation Camera, EOC)가 독립적인 시스템으로 구성되어 있다. 지구관측카메라는 유효 구경 100 mm, F/5의 광학계로 3-5 마이크론 파장영역을 관측하며, 국내에서 개발된 적외선 검출기의 우주 인증 시험과 유사시 한반도 적외선 감시를 주요 목적으로 하고 있다. 고도 700km에서 지상을 볼 때 약 42m/pixel의 공간분해능을 나타낼 것으로 기대하고 있다. 지구관측카메라의 인증 모델(Qualification Model)은 냉동기를 제외한 모든 부품이 국내기술로 제작되었으며, 미러 본딩 및 릴레이 렌즈 조립 기술, 적외선 영상 검교정 기술 등 다양한 경험과 도전을 제공했다. 이 발표에서는 지구관측카메라 인증모델을 이용하여 수행한 주요 시험 과정을 소개한다. 국내 회사 (주)i3 system에서 제작된 적외선 검출기는 $320\times256$ HgCdTe array (평균 양자효율 80% 이상) 이며 77K에서 정상적으로 운영된다. Micro Stirling Cooler에 의해 듀어는 전원을 켠 후 5분 이내에 검출기 운영온도인 77K까지 내려간다. 적외선 광학계의 정렬, 시스템 MTF 측정, 흑체 측정 및 검교정 작업을 수행한 후 야외에서 다양한 경우에 대해 Field Test를 진행했다. 이 발표에서는 Field Test 과정과 이를 통해 얻은 결과를 발표하고, FM (Flight Model) 제작에 있어 수정해야 할 사항들을 제안해 본다.

  • PDF