Proceedings of the Korean Society of Precision Engineering Conference
/
2004.10a
/
pp.1232-1235
/
2004
The purpose of this study is to design electrical stimulation system for pharyngeal dysfunction(dysphagia) in stroke patients. Pharyngeal muscle group activity is important, because contracting muscles provide the driving force at the initiation of the swallow and generate the pressure gradients necessary for bolus movement into the esophagus. Although we have many treatment methods for dysphagia, electrical stimulation system will be useful for stroke patients having dysphagia. Electrical stimulation can be divided into the body stimulation and electrodes. The body stimulation is divided again into frequency counter, time control and current measurement part. These parts are to control the current intensity, frequency and stimulating time. And they can be variable according to the patient's clinical assessment. The electrode plays a role to deliver the current from the system to the muscle. Also the position of the electrode can be variable according to the treatment method. We performed the clinical experiment with the stroke patient who has swallowing disorder. The videofluoroscopy was used for the observation. From the result of clinical experiment based on electrical stimulation, we expected that the dysfunction(in pharynx) level of the patient can be improved. However we could not have enough effectiveness of the treatment because of the number of patients, patient's adaptation and treatment period. We will design the optimized electrical stimulation system based on enough clinical experiment in the future.
The purpose of this study was to approve the capability of human sensibility evaluation based on physiological responses and real-time subjective assessments. Three well-trained healthy human subjects were participated in the experiments. We measured physiological responses such as Heart Rate Variability(HRV), Galvanic Skin Response(GSR) and skin temperature under rest and visual stimulation conditions, respectively. Off-time subjective assessments were recorded before and after visual stimulations. Real-time subjective assessments were recorded during visual stimulations. The results of physiological responses and off-time and real-time subjective assessments were quantified and compared. The results showed that the correlation between physiological responses and real-time subjective assessments was high (83%) for both the positive and negative visual stimulation. The correlation between the physiological responses and off-time subjective assessments was high (83%) for the negative visual stimulation but was low (15%) for the positive visual stimulation. Although the current observation is preliminary and requires more careful experimental study, it appears that the correlation between real-time subjective assessment and physiological responses is higher than that of the off-time subjective assessment and physiological responses.
The effects of type (high and low voltages) and time (3, 40 and 60 min postmortem) of stimulation on drip loss and meat color at 24 h post-mortem were determined on M. longissimus dorsi of 38 crossbred steers and heifers. In addition, the effect of pH early postmortem (70 min postmortem) on the rate and extend of meat tenderization was examined. Either high or low voltage stimulation at 3 min showed a tendency for faster pH decline (p=0.052) and higher drip loss (p=0.08), and improved the color dimensions of L*, a* and b* (p<0.01), compared to stimulation at 40 min. This was equivalent to approximately one unit of an AUSMEAT color chip. On the other hand, although there were significant differences in pH decline between high voltage stimulation at 40 and 60 min, and between low voltage stimulation at 40 min and control sides, drip loss and meat color did not differ significantly (p>0.05). The results suggested that early application of stimulation, regardless of type of stimulation, improved overall meat color at 24 h postmortem through its effect on faster glycolysing rate. However, if the pH decline was moderate, the benefit of electrical stimulation on meat color was not apparent. An intermediate pH decline resulted in the lowest shear force. Due to differential ageing rates the optimum pH at 70 min postmortem increased with ageing time from 5.96, 6.07, 6.12 and 6.14 for 1, 3, 7 and 14 days postmortem, respectively. This implied that a small difference in the rate of pH decline was important, especially carcasses stimulated for very early postmortem, and the optimum rate of pH decline varied with intended ageing period. The study suggests that the beneficial or adverse effects of electrical stimulation on drip loss, meat color and tenderness is determined by the rate of pH decline, rather than by stimulation treatment and time of application per se.
The purpose of this study was to determine if any differences exist in eye contact before and after vestibulaar stimulation in mentally retarded children. The subjects of this study were 20 mentally retarded children with a mean age of 9 years and 8 months and a mean intelligence quotient of $30.4{\pm}9.1$. Vestibular stimulation was given for 15 minutes, 5 times a week, for 4 weeks from September 1 to September 30, 1989. Equipment used included a rocking-horse, see-saw and scooter board. Two testers used a digital watch calibrated to 1/100 second to measure object-eye contact duration and the Blocks and Shapes test for determining frequency of object-eye contact in the subjects. The results of this study were as follows : 1. There was a significant prolongation in the duration of eye contact after 15 minutes of vestibular stimulation (p<0.005). 2. There was no significant difference in duration of eye-object contact between the first and last vestibular stimulation. 3. There was no significant difference in the length of time of attention paid to objects (frequency of eye-object contact) before and after 15 minutes of vestibular stimulation on the first vestibular stimulation. 4. There was no significant difference in the frequency of eye-object contact between the first and first vestibular stimulation. In conclusion, there was u significant improvement in duration of eye-object contact on intrasession measurement in mentally retarded children. However, there was no significant improvement over time after 4 weeks of vestibular stimulation on intersession measurement. Nor was there any statistically significant improvement in frequency of eye-object contact over time during the study period.
Gastro-intestinal mortility and transit time of barium sulfate after electroacupuncture were investigated in normal dogs and administration of xylatine in dogs. Electroacupuncture was performed with a current of 1.5 volt and 20 Hz at the acupoints of Tsu San Li(right(+) left(-) in dogs for 30 minutes. The results were as follows: 1. After electroacupuncture stimnlation in normal dogs, rates of stomach contractions was not changed, but amplitudes of stomach motility was markadly increased. The electroacupuncture stimulation tasted about 60 minutes after the end of electroacupuncture. 2. The stomach contractions was markedly increased, while the amplitudes of stomach motility was sligltly decreased by the administration of xylazine in dogs. 3. The rates of stomach contractions and amplitudes of motility were markedly increased after administration of xylazine in the electroacupuncture stimulated dogs. 4. Gastric emptying time o barium sulfate after electroacupuncture stimulation in dogs was highly significantly decreased compared with that of normal dogs(p < 0.01). 5. Small bowel transit time of barium sulfate after electroacupuncture stimulation in dogs was highly significantly decreased compared with that of normal dogs (p < 0.01). 6. Gastroduodenal transit time of barium sulfate after administration of xylazine following electroacupuncture stimulation dogs was blighty significantly decreased compared to that of dogs dosed with xylazine (p< 0.01). 7. Small bowel transit time of barium sulfate after administration of xylazine following electroacupuncture stimulation dogs markedly decreased compared to that of dogs dosed with xylazine (p < 0.05).
Use of electric pulp testing elicits painful response in vital teeth. In this study, we examined the excessive time from pain feeling to stimulation disconnection in clinical situation. D626D (Parkell Inc., USA.) scan type electric pulp tester was used in total of 23 young healthy individuals. Each of the right central incisors and first premolars were used as testing teeth. Stimulation disconnection was achieved by EMG in anterior belly of digastric muscle, finger span, and voice and the excessive stimulation time over the sensory thresh-old was recorded. As a result, we found that the short responses before the stimulation disconnection appeared following order:EMG, finger span, and voice. The EMG disconnection is suggested to be used to reduce the excessive stimulus time in electric pulp testing.
Yoo Ji Hye;Bae Ha Suk;Choi Byoung Cheol;Kim Sung Min
Journal of the Korean Society for Precision Engineering
/
v.22
no.7
s.172
/
pp.185-190
/
2005
The purpose of this study is to design electrical stimulation system fur stroke patients with pharyngeal dysfunction(dysphagia). Dysphagia is that the food has trouble in passing to the mouth from the stomach. Although we have many treatment methods for dysphagia, electrical stimulation system will be useful for stroke patients having dysphagia. Electrical stimulation system can be divided into body and electrodes. The body stimulation is composed to frequency counter, time control and current measurement part. These parts are to control the frequency, stimulating time and current intensity And they can be variable according to the patient's clinical assessment. The electrode plays a role to deliver the current from the system to the muscle. Also the position of the electrode can be variable according to the treatment method. We performed the clinical experiment with stroke patients who had swallowing disorder. The videofluoroscopy was used fur the observation. From the result of clinical experiment based on electrical stimulation, we expected that the dysfunction(in pharynx) level of the patient could be improved. However we could not have enough effectiveness of the treatment because of the number of patients, patient's adaptation and treatment period. We will design the optimized electrical stimulation system based on enough clinical experiment in the future.
The Transactions of the Korean Institute of Electrical Engineers D
/
v.55
no.10
/
pp.458-463
/
2006
The purpose of this work is to investigate the fundamental properties of the gradual muscle force potentiation. We investigated the dependence of force potentiation on both the pulse-amplitude and the pulse-duration with different ramp-up time. The experimental results showed that the force increment ratio (FIR) during constant electrical stimulation decreased with pulse-amplitude and also with pulse-duration. The FIR was greater with short ramp-up time in both the pulse-amplitude and pulse-width modulation. The feasible mechanism might be that the myosin light chain phosphorylation induces the force potentiation and it occurs only in the fast type muscle fibers which are recruited first. These observations indicate that muscle potentiation must be understood well for the accurate control of muscle force.
Evoked potentials(EP) are defined as electric responses of the nerves system to sensory stimulation. EPs are used mainly to test conduction in the visual, auditory, and somatosensory systems, especially in the central parts of these systems. Somatosensory evoked potentials (SEP) are the potentials elicited by stimulation of peripheral nerves and recorded at various sites along the sensory pathway. SEPs types consist mainly of SEPs to electric stimulation of arm or leg nerves. SEPs to arm stimulation are usually recorded simultaneously from clavicular, cervical, and scalp electrodes; SEPs to leg stimulation are recorded from lumbar, low thoracic, and scalp electrodes. Subject variables that have practical impotance are age, limb length, body height, and temperature. General clinical interpretation of abnormal SEPs wave decreases of peripheral conduction time, and abolition of SEPs recorded from different levels to identify lesions of peripheral nerves, plexus, nerve root, spinal cord, cauda equina, hemispheric brainstem, and cerebral parts of the somatosensory pathway.
Journal of The Korean Society of Integrative Medicine
/
v.10
no.2
/
pp.203-210
/
2022
Purpose : The purpose of this study was to investigate the effect of vestibular sensory stimulation exercise on the limit of stability, dynamic weight shift, and upper and lower extremities reaction time in adult women. Methods : This study was conducted with 30 female. All subjects were randomly and equally assigned to an experimental group and a control group of 15 each. Subjects assigned to the experimental group received vestibular sensory stimulation training for 6 weeks. For the intervention, vestibular sensory stimulation exercises were conducted by referring to the Hamid exercise method and the Cawthorne-Cooksey exercise method, and the control group did not receive any intervention. All subjects were tested for limit of stability, dynamic weight shift, and upper and lower extremities reaction time before and after the intervention. Results : The results of this study showed significant differences between groups in reaction time, moving velocity, and directional control in the limit of stability test after intervention. In the dynamic weight shift test after intervention, there was a significant difference between the groups in the slow directional control of left and right. And in the upper and lower extremities reaction time test after intervention, both scores and reaction time showed significant differences between groups. Conclusion : As a result, the three vestibular sensory stimulation exercises applied in this study improved the limit of stability, dynamic weight shift, and upper and lower extremities reaction time.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.