• 제목/요약/키워드: Stiffness Effect

검색결과 2,330건 처리시간 0.025초

파랑하중을 받는 부유체의 강성에 따른 응답 고찰 (Response Analysis of Floating Structure under Wave Loads Considering Stiffness)

  • 김병완;김영식;홍사영;경조현;조석규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.941-948
    • /
    • 2006
  • In this paper, the effect of stiffness on hydroelastic responses of plate-like floating structure under wave loads are studied. Direct method is used for the numerical analysis. In the numerical analysis, structural equation is formulated by finite element method(FEM) and higher order boundary element method(HOBEM) is employed for the analysis of fluid flow. A 1000m-long VLFS(Very Large Floating Structure) is considered in numerical analyses. By analyzing VLFS for various cases of stiffness, the characteristics of hydroelastic responses with the variation of stiffness are investigated.

  • PDF

Equations to evaluate fundamental period of vibration of buildings in seismic analysis

  • Sangamnerkar, Prakash;Dubey, S.K.
    • Structural Monitoring and Maintenance
    • /
    • 제4권4호
    • /
    • pp.351-364
    • /
    • 2017
  • In this study effects of various parameters like a number of bays, the stiffness of the structure along with the height of the structure was examined. The fundamental period of vibration T of the building is an important parameter for evaluation of seismic base shear. Empirical equations which are given in the Indian seismic code for the calculation of the fundamental period of a framed structure, primarily as a function of height, and do not consider the effect of number of bays and stiffness of the structure. Building periods predicted by these expressions are widely used in practice, although it has been observed that there is scope for further improvement in these equations since the height alone is inadequate to explain the period variability. The aim of this study is to find the effects of a number of bays in both the directions, the stiffness of the structure and propose a new period equation which incorporates a number of bays, plan area, stiffness along with the height of the structure.

가선계의 동특성 해석 (A Study on the Dynamic Characteristics of Catenary)

  • 최병두;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 창립기념 춘계학술대회 논문집
    • /
    • pp.525-532
    • /
    • 1998
  • In this study, dynamic characteristics of catenary that supplies electrical power to high-speed trains is investigated. A particular emphasis is placed on the effect of droppers on the dynamic response of the contact wire, a dropper is an element that connects the contact wire with the messenger wire so as to maintain near uniform compliance, Finite element model compressing 3 spans is constructed. For the linear model, droppers are modeled as linear springs with various stiffness values. Modal analysis is performed to obtain the natural frequencies and modes and the variation in the modal density distribution for changing stiffness values are noted. Impulse response is also obtained through computer simulation. In practice, dropper is a nonlinear element with low stiffness in compression and high stiffness in tension. Hence, dropper can be modeled as a nonlinear spring with hi-directional stiffness values. Impulse and harmonic responses are obtained for the nonlinear model through simulation. The responses aye also compared with the linear cases.

  • PDF

고온고압조건하에서의 핵연료 피복관 지지스프링의 하중-변위 특성 분석 (Analysis of Grid Spring Characteristic of Fuel Assembly in High Temperature and High Pressure Environment)

  • 이영호;김형규;정연호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2146-2150
    • /
    • 2004
  • To evaluate the variation of spring stiffness in nuclear plant operating condition, load-displacement tests ($P-{\delta}$ test) were performed using two kinds of space grid springs in high temperature and high pressure water. With increasing temperature, stiffness of each spring gradually decreased except $100{\sim}150^{\circ}C$. It is apparently showed that spring with convex shape had a relatively high stability of spring stiffness at high temperature compared with I-shaped spring. It is suggested that the variation of spring stiffness with temperature and spring shape should be considered as an important variable in the design and analysis of the fuel assembly.

  • PDF

Prediction of stiffness degradation in composite laminate with transverse cracking and delamination under hygrothermal conditions-desorption case

  • B. Boukert;M. Khodjet-Kesba;A. Benkhedda;E.A. Adda Bedia
    • Advances in aircraft and spacecraft science
    • /
    • 제11권1호
    • /
    • pp.1-21
    • /
    • 2024
  • The stiffness reduction of cross-ply composite laminates featuring a transverse cracking and delamination within the mid-layer is predicted through utilization of a modified shear-lag model, incorporating a stress perturbation function. Good agreement is obtained by comparing the prediction models and experimental data. The material characteristics of the composite are affected by fluctuations in temperature and transient moisture concentration distribution in desorption case, based on a micro-mechanical model of laminates. The transient and non-uniform moisture concentration distribution induces a stiffness reduction. The obtained results demonstrate the stiffness degradation dependence on factors such as cracks density, thickness ratio and environmental conditions. The present study underscores the significance of comprehending the degradation of material properties in the failure progression of laminates, particularly in instances of extensive delamination growth.

원전 기기 정착부의 내진검증 기법 사례연구 (Seismic Verification of Nuclear Power Plant Equipment Anchorage)

  • 서용표
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.215-223
    • /
    • 2000
  • In this study, the effect of stiffness ratio between base frame and anchorgae is evaluated and the seismic verification of nuclear power plant equipment anchorage is performed for typical equipment. The stiffness ratio between base frame and anchorage is mainly controlled by the effective height of side wall plate. And, the change of that stiffness ratio cause the large shift or ovreturning axis of equipment base. This shift of overturning axis of equipment base is able to reduce the factor of safety about 10%. Therefore, the adequate method for evaluating of effective height of side wall is required as further study.

  • PDF

순수비틀림을 받는 철근콘크리트 보의 균열후 비틀림 강성 (Postcracking Torsional Stiffness of Reinforced Concrete Beams under Pure Torsion)

  • 음성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.51-58
    • /
    • 1991
  • In staically indeterminate structures torsional stiffness is an important factor for prediction of mechanical behavior at all loading stages in reinfored concrete beams, which also for calculation of torsional moment. This paper proposes equation for postcracking torsional stiffness of reinforced concrete beams under pure torsion, which is derived considering the equilibrium and compatibility condition for shear panel based on the variable angle space truss model. The equation describes well the effect according to the variation of aspect ratio and steel volume ratio per unit concrete volume. It agress with experimental results in this paper as well as available literature.

  • PDF

바닥판의 휨강성이 고층건물의 지진거동에 미치는 영향 (The Effect of the flexural stiffness of Floor Slabs on The Seismic Response of Multi-story Building Structures)

  • 김현수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.170-177
    • /
    • 2000
  • Recently many high-rise apartment buildings are constructed using the box system which is composed only of concrete walls and slabs. Commercial softwares such as ETABS used for the analysis of high-rise apartment buildings are employing the rigid diaphragm assumption for simplicity in the analysis procedure. In general the flexural stiffness of floor slabs are ignored in the analysis, This assumption may be reasonable for the estimation of seismic response of framed structures. But in the case of the box system used in the apartment buildings floor slabs has major effects on the lateral stiffness of the structure. So if the flexural stiffness of slabs in the box system is ignored the lateral stiffness may be significantly underestimated, For these reasons it is recommended to use plate elements to represent the floor slabs. In the study A typical frame structure and a box system structure are chosen as the example structure. When a 20 story frame structure is subjected to the static lateral loads the displacements of the roof are 15.33cm and 17.52cm for the cases with and without the flexural stiffness of the floor slabs. And in case of box system the roof displacement was reduced from 16.18cm to 8.61cm The model without the flexural stiffness of floor slabs turned out to elongate the natural periods of vibration accordingly.

  • PDF

동특성 변화를 이용한 감쇠 구조물의 손상예측 (Prediction of the Damage in the Structure with Damping Using the Modified Dynamic Characteristics)

  • 이정윤
    • 한국소음진동공학회논문집
    • /
    • 제22권11호
    • /
    • pp.1144-1151
    • /
    • 2012
  • A damage in structure alters its dynamic characteristics. The change is characterized by changes in the modal parameter, i.e., modal frequencies, modal damping value and mode shape associated with each modal frequency. Changes also occur in some of the structural parameters; namely, the mass, damping, stiffness matrices of the structure. In this paper, evaluation of changes in stiffness matrix of a structure is presented as a method not only for identifying the presence of the damage but also locating the damage. It is shown that changed stiffness matrix can be accurately estimated a sensitivity coefficient matrix derived from modifying mode shapes, First, with 4 story shear structure models, the effect of presence of damage in a structure on its stiffness matrix is studied. By using these analytical model, the effectiveness of using change of stiffness matrix in detecting and locating damages is demonstrated. To validate the predicted changing stiffness and its location, the obtained results are compared to the reanalysis result which shows good agreement.

Damage and stiffness research on steel shape steel fiber reinforced concrete composite beams

  • Xu, Chao;Wu, Kai;Cao, Ping zhou;Lin, Shi qi;Xu, Teng fei
    • Computers and Concrete
    • /
    • 제24권6호
    • /
    • pp.513-525
    • /
    • 2019
  • In this work, an experimental research has been performed on Steel Fiber-Steel Reinforced Concrete (SFSRC)specimens subjected to four-point bending tests to evaluate the feasibility of mutual replacement of steel fibers and conventional reinforcement through studying failure modes, load-deflection curves, stiffness of characteristic points, stiffness degradation curves and damage analysis. The variables considered in this experiment included steel fiber volume percentage with and without conventional reinforcements (stirrups or steel fibers) with shear span depth ratios of S/D=2.5 and 3.5. Experimental results revealed that increasing the volume percentage of steel fiber decreased the creation and propagation of shear and bond cracks, just like shortening the stirrups spacing. Higher crack resistance and suturing ability of steel fiber can improve the stability of its bearing capacity. Both steel fibers and stirrups improved the stiffness and damage resistance of specimens where stirrups played an essential role and therefore, the influence of steel fibers was greatly weakened. Increasing S/D ratio also weakened the effect of steel fibers. An equation was derived to calculate the bending stiffness of SFSRC specimens, which was used to determine mid span deflection; the accuracy of the proposed equation was proved by comparing predicted and experimental results.