• 제목/요약/키워드: Stereotactic localization

검색결과 35건 처리시간 0.021초

방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발 (Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery)

  • 서태석;서덕영;박승훈;장홍석;최보영;윤세철;신경섭;박용휘;김일환;강위생;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

뇌 정위 생검술을 위한 영상지원 3차원 국재 프로그램 개발 (Development of Image Guided 3D Localization Program for Stereotactic Brain Biopsy)

  • 이도희;이동준
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.197-201
    • /
    • 2004
  • 뇌 신경계에 발생한 비정상조직 등 병소들을 수술적 방법으로 생체 조직검사 시 방사선 영상 공간과 실제 물리적 공간을 3 차원적으로 일치시키고 국재(localization)하는 영상지원 뇌 정위 수술은 혹시 발생할지도 모르는 후유증을 최소화할 수 있다. 본 연구는 대부분 고가의 대형 정위 수술 프로그램에 포함되어 있는 뇌수술을 영상 지원하는 정위적 국재 프로그램들 중 임상에서 수술 빈도가 높은 생체조직 검사 시술 시에 최소한의 기능으로 수술을 지원할 수 있는 프로그램을 개발하고 팬텀을 이용해 국재 정확도를 측정한 후 임상에서 사용 가능성을 평가하였다. 프로그램은 영상자료 입력, fiducial marker 등록, 목표점 좌표 지정 및 좌표 값 표시 등 3 부분으로 구성하였고 팬텀을 이용한 프로그램의 정확도를 측정결과 임상에서 요구되는 일반적인 국재 정확도 한계인 2 mm 이내였다. 이 프로그램은 고난도의 뇌 정위 생검 수술시 정확한 시술이 가능하도록 지원하여 수술의 위험도를 줄이고 수술 성공률 향상에 기여할 수 있으리라 생각된다.

  • PDF

QA용 두부 팬톰을 이용한 Hitchcoke CT 및 혈관조영 정위적 시스템에 대한 정확도 평가 (Evaluation of Accuracy on Hitchcoke CT/angio localization system using QA head phantom)

  • 김성현;서태석;윤세철;손병철;김문찬;신경섭
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 1998
  • 정위적 방사선 수술과 신경외과적 수술분야 에서는 상호보완적인 영상정보를 얻기 위하여 컴퓨터 단층촬영 (CT), 자기공명영상 (MRI) 그리고 혈관조영촬영이 사용된다. 본 연구의 목적은 여러 영상장치와 다목적 QA(Quality Control) 팬톰을 이용하면서, 정위적 방사선수술 및 신경외과적 수술분 야에서 두경부내의 병소에 대한 모양, 크기, 위치를 정확하게 결정하기 위한 3 차원 정위 시스템을 개발하는 것이다. 목표물의 정확한 위치를 정의하기 위하여, Hitchcoke 정위 프레임과 컴퓨터 단층 촬영 (CT)/혈관 조영촬영용 위치측정 보조기구들을 3차원 공간상에 9개의 목표물을 가진 팬톰에 고정하였다. 컴퓨터 단층촬영과 혈관 조영촬영을 이용하여 얻은 기하학적 팬톰의 영상들을 이용하여, 목표물의 3차원 정위좌표를 얻기위한 알고리즘이 개발되었다. 개발된 알고리즘에 의해 계산된 목표물들의 위치는 팬톰의 절대 좌표와 비교 되었고, 각 CT 영상에서의 목표물들은 뇌혈관촬영 영상위에 상호 중첩될 수 있도록 개발 되었다. 512$\times$512 메트릭스와 2mm 슬라이스 두께를 가진 컴퓨터 단층촬영에 있어서는 1.02$\pm$0.17 mm의 평균거리오차를 보였고, 혈관 조영촬영인 경우에는 0.41$\pm$0.05mm 의 평균거리오차를 보였다. 목표물의 위치를 결정하는데 있어서 결과로 나온 정확도는 개발된 시스템이 정위적 방사선수술과 신경외과적수술을 위해 충분히 신뢰성이 있음을 확인해주었다.

  • PDF

뇌정위 수술 보조 로봇 시스템의 안전성과 유효성: 체계적 문헌고찰 (Effectiveness and Safety of Robot-Assisted Brain Stereotactic Surgery: A Systematic Review)

  • 박선영;전미혜
    • 보건의료기술평가
    • /
    • 제6권2호
    • /
    • pp.142-147
    • /
    • 2018
  • Objectives: The purpose of this study is to evaluate the safety and effectiveness of Robot-Assisted Brain Stereotactic Surgery with a systematic review. Methods: Electronic literature was searched using KoreaMed, Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library on 6th April 2017. Two authors screened 1218 citations. Duplicated articles of 456 excluded, the remaining 762 articles were reviewed with title and abstract. Results: A total of 8 studies were selected in this review. The device used in all studies was $ROSA^{TM}$. In one cohort study comparing the intervention ($ROSA^{TM}$) with the control (conventional stereotactic surgery), hematoma was reported no significant difference between groups. In six descriptive studies, one study reported hematoma 10% (10/100) and temporary nerve impairment 6% (6/100) using the ROSA; while five descriptive study did not report any complications. In one cohort, the localization precision were 1.2 mm in the intervention group and 1.1 mm in the control group; the localization success rate as 78.2% in the intervention group and 76.2% in the control group in one cohort; and the average time for surgery as 130 min for the intervention group and 352 min for the control group in one cohort. Four studies reported the localization success rate as 100%; two out of three articles reported the overall time for surgery as 56 min and 90 min, while one article reported the time as less than one hour in 50% of patients (50/100); two articles reported in epilepsy patients, the condition after the surgery was Engel level I in 66.2%, 75% patients, Engel level II-III in 25%, 26.5% patients, and Engel level 4 in 7.3% patients. Conclusion: Robot-Assisted Brain Stereotactic Surgery is a safe and accurate technique that can significantly reduce the time for the brain stereotactic surgery. However, further studies are needed to generalize the results.

Stereotactic Body Radiation Therapy for Treatment of Spinal Bone Metastasis

  • Cihan, Yasemin Benderli
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권3호
    • /
    • pp.937-938
    • /
    • 2016
  • Stereotactic body radiation therapy (SBRT) appears an effective and safe treatment modality for spinal bone metastasis, which can enhance local control and improve quality of life. Life expectation, predicted fracture risk, localization, quality, size and number of metastasis and presence or absence of nerve compression seem to be important factors in decision-making for treatment. Further studies are needed to identify subsets of patient which will most benefit from treatment.

유방촬영술 유도하 중재 시술 (Mammography-Guided Interventional Procedure)

  • 최우정;김학희
    • 대한영상의학회지
    • /
    • 제84권2호
    • /
    • pp.320-331
    • /
    • 2023
  • 유방촬영술을 이용한 유방암 검진은 표준 영상 방법이다. 초음파에서 보이지 않고 유방촬영술이나 디지털 유방 토모신테시스에서만 보이는 의심스러운 석회화, 구조 왜곡의 조직학적 진단을 위해 입체정위생검과 유방촬영술 유도하 수술 전 위치결정술을 시행한다. 본 종설에서는 입체정위생검의 적응증 및 비적응증, 방법, 입체정위생검 후 클립 삽입과 디지털 유방 토모신테시스 유도하 입체정위생검에 대해 알아보고자 한다. 또한, 유방촬영술 유도하 수술 전 위치결정술을 침위치결정술과 비침위치결정술로 나누어 소개하고자 한다.

정위적 방사선 수술에서 물팬텀을 이용한 목표점 및 전달 선량확인 (Target Localization and Dose Delivery Verification used a Water Phantom in Stereotactic Radiosurgery)

  • 강영남;이동준;권수일;권양
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.19-28
    • /
    • 1996
  • 정위적 방사선수술 (Stereotactic radiosurgery) 은 병소(region)의 위치를 정확히 결정하고 치료에 요구되는 방사선량이 정확히 전달되는 것이 중요하다. 본 연구는 이를 실험적으로 확인할 목적으로 특별히 고안된 물팬텀 (water phantom)을 개발하여 Leksell 정위기구 (Leksell Stereotactic Frame; LSF)에 부착하여 방사선수술을 시행하였다. 방사선 수술에는 Leksell 감마나이프 (Gamma Knife Unit; GKU) 와 LSF를 사용하였으며 실험을 위해 개발된 팬텀은 1mm 두께 플라스틱의 직경 160mm의 구형으로 물을 채울수 있는 구조로 되어있다. 측정장치로서는 목표점 설정(target localization)을 위한 필름과 전달 선량(dose delivery) 측정을 위해 이온 전리함(ionchamber) 을 사용하였으며 이를 팬텀의 목표점에 각각 위치시킬 수 있도록 설계하였다. 본 연구에서 목표점 확인은 허용 오차범위인 $\pm$0.5 mm 이내에서의 값을 보였으며 선량전달값은 $\pm$3% 정도의 오차로 허용값내에 있음을 보여주었다. 본 연구에서 개발된 팬텀으로 측정된 값이 모두 허용 오차범위 내에 있음을 보여주었고 이로인해 GKU 및 LSF의 주기적 QA(Quality Assurance)에 계속적으로 사용할수 있게 되었다.

  • PDF

컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발 (Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography)

  • 김성현;서태석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF