• Title/Summary/Keyword: Stereotactic

Search Result 410, Processing Time 0.027 seconds

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Excellent Local Tumor Response after Fractionated Stereotactic Radiation Therapy for Locally Recurrent Nasopharynx Cancer (국소 재발 비인강암에 대한 정위적 방사선 분할 치료의 적용)

  • Lim Do Hoon;Chio Dong Rak;Kim Moon Kyung;Kim Dae Yong;Huh Seung Jae;Baek Chung-Hwan;Chu Kwang Chol;Yoon Sung Soo;Park Keunchil;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.19-26
    • /
    • 1997
  • Purpose : This study is to report experience with Fractionated Stereotactic Radiation Therapy (FSRT) for locally recurrent nasopharynx cancer after curative conventional radiation therapy. Materials and Methods : Three Patients with locally recurrent and symptomatic nasopharynx cancer were given FSRT as reirradiation method between the Period of September of 1995 and August of 1996 For two Patients, application of FSRT is their third radiation therapy directed to the nasopharynx. Two patients were given low dose chemotherapy as radiation sensitizer concurrently with FSRT Authors used 3-dimensional coordinate system by individually made, relocatable Gill-Thomas-Cosman (GTC) stereotactic frame and multiple non-coplanar arc therapy dose Planning was done using Xknife-3. Total of 45 Gy/18 fractions or 50 Gy/20 fractions were given. Results : Authors observed satisfactory symptomatic improvement and remarkable objective tumor size decrease by follow-up MR images taken 1 month Post-FSRT in ali three patients, while no neurologic side effect attributable to reirradiation was noticed. Two died at 7 and 9 months with loco-regional and distant seeding outside FSRT field, while one patient is living for 4 month. Conclusion Authors experienced satisfactory therapeutic effectiveness and safety of FSRT as reirradiatlon method for locally recurrent nasopharynx cancer Development of more effective systemic chemotherapeutic regimen is desired for distant metastasis

  • PDF

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Evaluation of Detector Dependency on Collimator in SRS: Compared Detectors; CC01, CC13, SFD (뇌정위적 방사선수술 시 콜리메이터 크기 변화에 따른 검출기 의존성 평가)

  • Bae, Yong-Ki;Bang, Dong-Wan;Park, Byung-Moon;Kang, Min-Yeong;Kim, Yeon-Rye
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.109-113
    • /
    • 2008
  • Purpose: To evaluate the detector dependency in the various collimator size for Stereotactic Radiosugery (SRS). Materials and Methods: This study was performed with 6 MV photon beam (Varian 21EX, Varian, US) and the measurement detectors are used by ion chamber CC01, CC13 (Wellhofer, Germany) and stereotactic diode detector (SFD, Wellhofer, Germany). SRS collimator size was used by ${\varphi}$5, 10, 20, 30 mm (Brain Lab, Germany). Percentage depth dose (PDD) was measured at SSD 100 cm and field size 10×10 cm from individual detectors. Ouput factor was measured by using same setup of PDD and with maximum dose depth. Data was normalized at field size $10{\times}10\;cm$. Beam profile was measured at SSD 100 cm in SRS collimator ${\varphi}$10, 30 mm and field $10{\times}10\;cm$ and a comparison of FWHM (full width half maximum), penumbra width (20~80%). Results: The CC13 detector was overestimated 16% than other detectors from the PDD in the 5 mm collimator. Output factors were underestimated CC01 28%, CC13 72% in the 5 mm collimator and CC01 9.6%, CC13 25% in the 10 mm collimator than the SFD. Maximum difference was 3% at the FWHM of the dose profile in the 10 mm collimator and difference of the 30 mm collimator was 0% at the FWHM. Penumbra width was increased CC01 122%, CC13 194% in the 10 mm collimator and CC01 68%, CC13 185% in the 30 mm collimator than the SFD. Conclusion: It is very important for accurate dosimetry to select a detector in small field. The SFD was considered with the most accurate dosimeter for small collimator dosimetry in this study.

  • PDF

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

The consideration about exact set-up with stereotactic radiosurgery for lung cancer. (폐암 환자의 전신 정위적 방사선 수술시 정확한 SET UP에 대한 고찰)

  • Seo, Dong-Rin;Hong, Dong-Gi;Kwon, Kyung-Tea;Park, Kwang-Ho;Kim, Jung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose : What confirm a patient's set-up precisely is an important factor in stereotactic radiosurgery Especially, the tumor is moved by respiration in case of lung cancer. So it is difficult to confirm a exact location by L-gram or EPID. I will verify a exact patient's set-up about this sort of problem by verification system(exactrac 3.0) Materials and Methods : The patient that had lung cancer operated on stereotactic radiosurgery is composed of 6 people. The 5 patients use an ABC tool and 1 patient doesn't use it. I got such a patient's L-gram and EPID image by Body frame(elekta, sweden), compared Ant. image with Lat. one, and then confirmed a set-up. I fused DRR image of CT and X-ray image of Verification system(exactrac 3.0) 3 dimensional, analyzed the coordinate value(vertical, longitudinal, lateral), and then confirmed a difference of existing method. Results : In case of L-gram and EPID, we judge an exact of the patient's set-up subjectively, and on we could treat the patient with radiation. As a result of using Verification system(exactrac 3.0), coordinate value(vertical, longitudinal, lateral) of patient's set-up was comprised within 5mm. We could estimate a difference of the coordinate value visually and objectively. Consequently, Verification system(exactrac 3.0) was useful in judging an exact patient's set-up. Conclusion : In case of Verification system(exactrac 3.0), we can confirm an exact patient's set-up at any time whenever, However, there are several kinds of the demerit. First, it is a complex process of confirmation than the existing process. Second, thickness of CT scan slice is within 3mm. The last, X-ray image has to have shown itself clearly. If we solve this problem. stereotactic radiosurgery will be useful in treating patients why we can confirm an exact patient's positioning easily.

  • PDF

Radiation Dose of Lens and Thyroid in Linac-based Radiosurgery in Humanoid Phantom (선형가속기형 방사선수술시 인형 팬텀에서 수정체 및 갑상선 선량)

  • Kim, Dae-Yong;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.517-529
    • /
    • 1998
  • Purpose : Although many studies have investigated the dosimetric aspects of stereotactic radiosurgery in terms of target volume, the absorbed doses at extracranial sites: especially the lens or thyroid - which are sensitive to radiation for deterministic or stochastic effect -have infrequently been reported. The aim of this study is to evaluate what effects the parameters of radiosurgery have on the absorbed doses of the lens and thyroid in patients treated by stereotactic radiosurgery, using a systematic plan in a humanoid phantom. Materials and Methods : Six isocenters were selected and radiosurgery was planned using the stereotactic radiosurgery system which the Department of Therapeutic Radiology at Seoul National University College of Medicine developed. The experimental radiosurgery plan consisted of 6 arc planes per one isocenter, 100 degrees for each arc range and an accessory collimator diameter size of 2 cm. After 250 cGy of irradiation from each arc, the doses absorbed at the lens and thyroid were measured by thermoluminescence dosimetry. Results : The lens dose was 0.23$\pm$0.08$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the lens and was 0.76$\pm$0.12$\%$ of the maximum dose for each isocenter when the exit beam passed through the lens. The thyroid dose was 0.18$\pm$0.05$\%$ of the maximum dose for each isocenter when the exit beam did not pass through the thyroid and was 0.41$\pm$0.04$\%$ of the maximum dose for each isocenter when the exit beam Passed through the thyroid. The passing of the exit beam is the most significant factor of organ dose and the absorbed dose by an arc crossing organ decides 80$\%$ of the total dose. The absorbed doses of the lens and thyroid were larger as the isocenter sites and arc planes were closer to each organ. There were no differences in the doses at the surface and 5 mm depth from the surface in the eyelid and thyroid areas. Conclusion : As the isocenter and arc plane were placed closer to the lens and thyroid, the doses increased. Whether the exit beams passed through the lens or thyroid greatly influenced the lens and thyroid dose. The surface dose of the lens and thyroid consistently represent the tissue dose. Even when the exit beam passes through the lens and thyroid, the doses are less than 1$\%$ of the maximum dose and therefore, are too low to evoke late complications, but nevertheless, we should try to minimize the thyroid dose in children, whenever possible.

  • PDF

Diagnostic Performance of Digital Breast Tomosynthesis with the Two-Dimensional Synthesized Mammogram for Suspicious Breast Microcalcifications Compared to Full-Field Digital Mammography in Stereotactic Breast Biopsy (정위적 유방 조직검사 시 미세석회화 의심 병변에서의 디지털 유방단층영상합성법과 전역 디지털 유방촬영술의 진단능 비교)

  • Jiwon Shin;Ok Hee Woo;Hye Seon Shin;Sung Eun Song;Kyu Ran Cho;Bo Kyoung Seo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1090-1103
    • /
    • 2022
  • Purpose To evaluate the diagnostic performance of digital breast tomosynthesis (DBT) with the two-dimensional synthesized mammogram (2DSM), compared to full-field digital mammography (FFDM), for suspicious microcalcifications in the breast ahead of stereotactic biopsy and to assess the diagnostic image visibility of the images. Materials and Methods This retrospective study involved 189 patients with microcalcifications, which were histopathologically verified by stereotactic breast biopsy, who underwent DBT with 2DSM and FFDM between January 8, 2015, and January 20, 2020. Two radiologists assessed all cases of microcalcifications based on Breast Imaging Reporting and Data System (BI-RADS) independently. They were blinded to the histopathologic outcome and additionally evaluated lesion visibility using a fivepoint scoring scale. Results Overall, the inter-observer agreement was excellent (0.9559). Under the setting of category 4A as negative due to the low possibility of malignancy and to avoid the dilution of malignancy criteria in our study, McNemar tests confirmed no significant difference between the performances of the two modalities in detecting microcalcifications with a high potential for malignancy (4B, 4C, or 5; p = 0.1573); however, the tests showed a significant difference between their performances in detecting microcalcifications with a high potential for benignancy (4A; p = 0.0009). DBT with 2DSM demonstrated superior visibility and diagnostic performance than FFDM in dense breasts. Conclusion DBT with 2DSM is superior to FFDM in terms of total diagnostic accuracy and lesion visibility for benign microcalcifications in dense breasts. This study suggests a promising role for DBT with 2DSM as an accommodating tool for stereotactic biopsy in female with dense breasts and suspicious breast microcalcifications.

Cytologic Features of Intracranial Germ Cell Tumors in Crush Preparation (두개내 악성 생식세포종양의 압착도말 세포학적 소견)

  • Yim, Hyun-Ee;Kim, Jung-Sun;Shim, Chul
    • The Korean Journal of Cytopathology
    • /
    • v.7 no.2
    • /
    • pp.177-184
    • /
    • 1996
  • Intraoperative cytologic examination of intracranial tumors using crush preparation provides useful information in operative decision making. The diminutive nature of many biopsy specimens, particularly those obtained by stereotactic neurosurgical procedures emphasizes the importance of combining the cytologic smear method with conventional frozen section interpretation. The great advantage of the cytologic smear method resides in its suitability for the study of minute fragments of tissue, allowing retention of the majority of the specimen for optimal processing. We present the cytologic features of 3 cases of intracranial germ cell tumors(2 germinomas and 1 endodermal sinus tumor), using crush preparation during intraoperative diagnosis and compare them with histologic findings. The cytologic features of the germ cell tumors were similar to those of the respective gonadal counterparts. The cytologic differential diagnosis of both types of germ cell tumors is described.

  • PDF

Systemic Nocardiosis Mimicking Disease Flare-up after Discontinuation of Gefitinib in a Patient with EGFR-Mutant Lung Cancer

  • Choi, Mihong;Lee, Youngjoo;Hwang, Sang Hyun;Lee, Jin Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.77 no.6
    • /
    • pp.271-273
    • /
    • 2014
  • Disease flare-up after discontinuing epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor (TKI) has been considered as a critical issue in lung cancer patients who have experienced radiologic progression after showing initial durable response. This is a case of systemic nocardiosis that occurred after chronic steroid use for radionecrosis from stereotactic radiosurgery. It was initially thought as a disease flare-up after stopping EGFR-TKI.