• Title/Summary/Keyword: Stereotactic

Search Result 403, Processing Time 0.034 seconds

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Postoperative External Beam Radiotherapy for Medulloblastoma (수아세포종의 수술 후 외부 방사선치료)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.101-106
    • /
    • 2000
  • Purpose : This study was peformed to evaluate the effectiveness and tolerance of craniospinal irradiation for patients with modulloblastoma and to define the optimal radiotherapeutic regimen. Materials and Methods : We retrospectively analyzed the records of 43 patients with modulloblastoma who were treated with external beam craniospinal radiotherapy at our institution between May, 1984 and April, 1998. Median follow up period was 47 months with range of 18 to U months. Twenty seven patients were male and sixteen patients were female, a male to female ratio of 1.7:1. Surgery consisted of biopsy alone in 5 patients, subtotal excision in 24 patients, and gross total excision in 14 patients. All of the patients were treated with craniospinal irradiation. All of the patients except four received at least 5,000 cGy to the posterior fossa and forty patients received more than 3,000 cGy to the spinal cord. Results : The overall survival rates at 5 and 7 years for entire group of patients were 57$\%$ and 56$\%$, respectively. Corresponding disease free survival rates were 60$\%$ and 51$\%$, respectively, The rates of disease control in the posterior fossa were 77$\%$ and 67$\%$ at 5 and 7 years. Gross total excision and subtotal excision resulted in 5 year overall survival rates of 76$\%$ and 66$\%$, respectively, In contrast, those patients who had biopsy alone had a 5 year survival rate of only 40$\%$. Posterior fossa was a component of failure in 11 of the 18 recurrences. Seven recurrences were isolated to the posterior fossa. Four patients had neuraxis recurrences, three had distant metastasis alone and four had multiple sites of failure, all involving the primary site. Conclusion : Craniospinal irradiation for patients with moduiloblastoma is an effective adjuvant treatment without significant treatment related toxicitles. There is room for Improvement in terms of posterior fossa control, especially in biopsy alone patients. The advances in radiotherapy including hypefractionation, stereotactic radiosurgery and 3D conformal radiotherapy would be evolved to improve the tumor control rate at primary site.

  • PDF

Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers (폐암환자의 종양추적 정위방사선치료를 위한 삼차원 및 사차원 방사선치료계획의 비교)

  • Chai, Gyu-Young;Lim, Young-Kyung;Kang, Ki-Mun;Jeong, Bae-Gwon;Ha, In-Bong;Park, Kyung-Bum;Jung, Jin-Myung;Kim, Dong-Wook
    • Radiation Oncology Journal
    • /
    • v.28 no.4
    • /
    • pp.238-248
    • /
    • 2010
  • Purpose: To compare the dose distributions between three-dimensional (3D) and four-dimensional (4D) radiation treatment plans calculated by Ray-tracing or the Monte Carlo algorithm, and to highlight the difference of dose calculation between two algorithms for lung heterogeneity correction in lung cancers. Materials and Methods: Prospectively gated 4D CTs in seven patients were obtained with a Brilliance CT64-Channel scanner along with a respiratory bellows gating device. After 4D treatment planning with the Ray Tracing algorithm in Multiplan 3.5.1, a CyberKnife stereotactic radiotherapy planning system, 3D Ray Tracing, 3D and 4D Monte Carlo dose calculations were performed under the same beam conditions (same number, directions, monitor units of beams). The 3D plan was performed in a primary CT image setting corresponding to middle phase expiration (50%). Relative dose coverage, D95 of gross tumor volume and planning target volume, maximum doses of tumor, and the spinal cord were compared for each plan, taking into consideration the tumor location. Results: According to the Monte Carlo calculations, mean tumor volume coverage of the 4D plans was 4.4% higher than the 3D plans when tumors were located in the lower lobes of the lung, but were 4.6% lower when tumors were located in the upper lobes of the lung. Similarly, the D95 of 4D plans was 4.8% higher than 3D plans when tumors were located in the lower lobes of lung, but was 1.7% lower when tumors were located in the upper lobes of lung. This tendency was also observed at the maximum dose of the spinal cord. Lastly, a 30% reduction in the PTV volume coverage was observed for the Monte Carlo calculation compared with the Ray-tracing calculation. Conclusion: 3D and 4D robotic radiotherapy treatment plans for lung cancers were compared according to a dosimetric viewpoint for a tumor and the spinal cord. The difference of tumor dose distributions between 3D and 4D treatment plans was only significant when large tumor movement and deformation was suspected. Therefore, 4D treatment planning is only necessary for large tumor motion and deformation. However, a Monte Carlo calculation is always necessary, independent of tumor motion in the lung.

The Role of Radiotherapy in the Management of Supratentorial Low Grade Astrocytoma (천막 상부 저분화 성상세포종의 치료에 있어 방사선 치료의 역할)

  • Lee, Kyung-Ja;Chang, Hye-Sook;Song, Mi-Hee
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 1997
  • Purpose : To evaluate the role of radiotherapy in the management of incompletely resected supratentorial low grade astrocytoma with the analysis of the survival, the Pattern of failure, and the prognostic variables affecting survival. Material and methods : Between January 1990 and December 1995, fifty-one patients with supratentorial low grade astrocytoma received radiotherapy after subtotal resection(16 patients) or stereotactic biopsy(35 patients) at Asan Medical Center, External radiotherapy was done by conventional fractionation with the total dose of 4820cGy to 6000cGy(median 5580cGy) and partial brain volume. The follow-up was done from 6 to 79 months(median 48 months) Result : Overall actuarial survival rate at 2 and 5 years were $83.4\%\;and\;54.8\%$, respectively. Progression free survival at 2 and 5 years were $67.4\%\;and\;48.7\%$, respectively The significant prognostic factors affecting overall survival rate were the performance status, 1 stage, histologic subtype, radiation field and radiation response. The major pattern of failure was local failure, such as Progressive disease and primary site recurrence in 23 patients $(45.1\%)$. Progression free survivors excluding 2 patients were physically and intellectually intact without major neurologic deficit. Conclusion : Although the follow-up period of this study was relatively short, overall actuarial and progression free survival rate were encouraging. Patients with good performance status, lower T stage, pilocytic subtype, patients treated with small radiation field and radiation responder showed better survival. As the local failure was the major pattern of failure, the various efforts to decrease the local failure is necessary.

  • PDF

Analysis of Prognostic Factors in Glioblastoma Multiforme (다형성 교모세포증 환자의 예후인자 분석)

  • Chang Sei Kyung;Suh Chang Ok;Lee Sang Wook;Keum Ki Chang;Kim Gwi Eon;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.181-189
    • /
    • 1996
  • Purpose : To find the more effective treatment methods that improving the survival of patients with glioblastoma multiforme(GBM), we analyze the prognostic factors and the outcome of therapy in patients with GBM. Materials and Methods : One hundred twently-one patients with a diagnosis of GBM treated at Severance Hospital between 1973 and 1993 were analyzed for survival with respect to patients characteristics, that is, duration of symptom, age, and Karnofsky performance status, as well as treatment related variables such as extent of surgery and radiotherapy. Results : The median survival time(MST) and 2-year overall survival rate (OSR) of the patients with GBM were 13 months and $20.8\%$, respectively. Duration of symptom, age, Karnofsky performance status(KPS), radiotherapy, and extent of surgical resection were associated with improved survial in a univariate analysis. Patients whose duration of symptom was longer than 3 months, had the 2-year OSR of $47.2\%$(p=0.0082), who were younger than age 50, $32.9\%$(p=0.0003) In patients with a KPS of 80 or higher, the 2-rear OSR was $36.9\%$(p=0.0422). Patients undergoing radiotherapy had the 2-year OSR of $22.9\%$(p=0.0030), and surgical resection of $23.3\%$ (p<0.000). A Cox regression model confirmed a significant correlation of duration of symptom, age, radiotherapy, and extent of surgical resection with survival, excluding KPS(P=0.8823). The 2-year OSR were $22.3\%$ and $19.4\%$, combined with chemotherapy or without, respectively(p=0.6028). The duration of symptom of 3 months or shorter, 50 years of age or older, and undergoing stereotactic biopsy only were considered as risk factors, then patients without any risk factors had the MST of 29 months and 2-year OSR of $53.9\%$ compared to 4 months and $0\%$ for Patients who had all 3 risk factors. Most of all treatment failures occurred in the primary tumor site($80.4\%$). Conclusion : The duration of symptom, age, radiotherapy, and extent of surgical resection were a prognostically significant indeuendent variables. To get a better survival, it seems to be reasonable that the study design which improves the local control rates is warranted.

  • PDF

Evaluation of Tissue Inhomogeneity for Gamma-knife Radiosurgery Using Film Dosimetry (감마 나이프 방사선 수술시 필름 선량 측정에 의한 조직 불균일성에 대한 연구)

  • Cho, Heung-Lae;Shon, Seung-Chang;Shu, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.325-335
    • /
    • 1998
  • Purpose : Since the mid cranial fossa is composed of various thickness of bone, the tissue inhomogeneity caused by bone would produce dose attenuation in cobalt-60 gamma knife irradiation. The correction factor for bone attenuation of cobalt-60 which is used for gamma knife source is -3.5$\%$. More importantly, nearly all the radiosurgery treatment planning systems assume a treatment volume of unit density: any perturbation due to tissue inhomogeneity is neglected, This study was performed to confirm the bone attenuation in mid cranial fossa using gamma knife. Materials and Methods : Computed tomography was performed after Leksell stereotactic frame had been liked to the Alderson Rando Phantom (human phantom) skull area. Kodak X-omat V film was inserted into two sites of pituitary adenoma point and acoustic neurinoma point, and irradiated by gamma knife with 14mm and 18mm collimator. An automatic scanning densitometer with a 1mm aperture is used to measure the dose profile along the x and y axis. Results : Isodose curve constriction in mid cranial fossa is observed with various ranges. Pituitary tumor point is greater than acoustic neurinoma point (0.2-3.0 mm vs 0.1-1.3 mm) and generally 14 mm collimator is greater than 18mm collimator (0.4-3.0 mm vs. 0.2-2.2 mm) Even though the isodose constriction is found, constriction of 50$\%$ isodose curve which is used for treatment reference line does not exceed 1 mm. This range is too small to influence the treatment planning and treatment results. Conclusion : Radiosurgery planning system of gamma knife does not show significant error to be corrected without consideration of bone attenuation.

  • PDF

Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films (사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름)

  • Jang Ji-Sun;Shin Dong-Oh;Choi Byung-Ock;Lee Tae-Kyu;Choi Ihl-Bohng;Kim Moon-Chan;Kwon Soo-Il;Kang Young-Nam
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • The accuracy of the dosimetry in the Cyberknife system is accomplishing important role from all processes of the stereotactic radiosurgery. In this study, we estimated relative output factors for Cyberknife. All measurements were peformed by six different detectors: diode detector, X-Omat V film, Gafchromic EBT film, 0.015 cc, 0.125 cc and 0.6 cc ionization chamber The diode detector and three ionization chambers peformed using water phantom at 80 cm SSD and 1.5 cm depth. When the film measurements were peformed, the water phantom was replaced with a solidwater phantom. Each collimator normalized with respect to the output factor of the largest collimator (60 mm). For the collimators over than 30 mm, the output factors from the different detectors showed a good agreement within 0.5% except 0.6 cc ion chamber For the collimators less than 15 mm, there were substantial differences In the output factors among different detectors. That is, the value of output factor for the 5 mm collimator of a diode and Gafchromic film was each $0.656{\pm}0.009$ and $0.777{\pm}0.013$. In the ion chamber and diode detector, those difference were due to the presence of large dose gradients and lack of electronic equilibrium in narrow megavoltage x-ray beams Therefore, the Gafchromic EBT film were considered more accurate than the others detectors.

  • PDF

Comparison and Evaluation of radiotherapy plans by multi leaf collimator types of Linear accelerator (선형가속기의 다엽콜리메이터 형태에 따른 치료계획 비교 평가)

  • Lim, Ji Hye;Chang, Nam Joon;Seok, Jin Yong;Jung, Yun Ju;Won, Hui Su;Jung, Hae Youn;Choi, Byeong Don
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.129-138
    • /
    • 2018
  • Purpose : An aim of this study was to compare the effect of multi leaf collimator(MLC) types for high dimension radiotherapy in treatment sites used clinically. Material and Method : 70 patients with lung cancer, spine cancer, prostate cancer, whole pelvis, head and neck, breast cancer were included in this study. High definition(HD) MLC of TrueBeam STx (Varian Medical system, Palo Alto, CA) and millenium(M) MLC of VitalBeam (Varian Medical system, Palo Alto, CA) were used. Radiotherapy plans were performed for each patient under same treatment goals with Eclipse (Version 13.7, Varian Palo Alto USA, CA). To compare the indicators of the radiotherapy plans, planning target volume(PTV) coverage, conformity index(CI), homogeneity index(HI), and clinical indicators for each treatment sites in normal tissues were evaluated. To evaluate low dose distribution, $V_{30%}$ values were compared according to MLC types. Additionally, length and volume of targets for each treatment sites were investigated. Result : In stereotatictic body radiotherapy(SBRT) plan for lung, the average value of PTV coverage was reduced by 0.52 % with HD MLC. With SBRT plan using HD MLC for spine, the average value of PTV coverage decreased by 0.63 % and maximum dose decreased by 1.13 %. In the test of CI and HI, the values in SBRT plan with HD MLC for spine were 1.144, 1.079 and the values using M MLC were 1.160, 1.092 in SBRT plan for lung, The dose evaluation of critical organ was reduced by 1.48 % in the ipsilateral lung mean dose with HD MLC. In prostate cancer volumetric modulated arc therapy(VMAT) with HD MLC, the mean dose and the $V_{30}$ of bladder and the mean dose and the $V_{25}$ of rectum were reduced by 0.53 %, 1.42 %, 0.97 %, and 0.69 %, respectively (p<0.05). The average value of heart mean dose was reduced by 0.83 % in breast cancer VMAT with M MLC. Other assessment indices for treatment sites showed no significant difference between treatment plans with two types of MLC. Conclusion : Using HD MLC had a positive impact on the PTV coverage and normal tissue sparing in usually short or small targets such as lung and spine SBRT and prostate VMAT. But, there was no significant difference in targets with long and large such as lung, head and neck, and whole pelvis for VMAT.

  • PDF

Feasibility study of using Halcyon LINAC for Double-target spine stereotactic body radiation therapy (이중 표적 척추 전이암의 체부정위방사선치료 시 Halcyon LINAC의 치료 유용성 평가)

  • Jeong Hee Ju;An Ye Chan;Park Byung Suk;Park Myung Hwan;Park Yong Chul
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.51-60
    • /
    • 2022
  • Objectives: The purpose is to evaluate dosimetric performance and delivery efficiency of VMAT with Halcyon LINAC for double target spine SBRT Materials and Methods: 12 patients with spine oligometastases were retrospectively studied. Single-isocenter spine SBRT plans was established using Halcyon® with Dual Layer MLC and Truebeam® with High Definition MLC. All patients' plans were created in Eclipse TPS through the identical conditions and optimization. C.I, H.I, G.I (Gradient Index), maximal and volumetric doses to spinal cord and low dose area were evaluated for comparison of both plans. Also, total MU and BOT(Beam On Time) were evaluated. Results: Halcyon plans was no Statistical differences in C.I and H.I. However, the average of G.I was 4.64 for Halcyon, which decreased to 5.5% compared to Truebeam (P<0.001). Halcyon plans demonstrated statistically significant reduced G.I. The average of 50% and 25% isodose volume was 487.56 cc (-3.82%, P<0.001), 1859.45 cc (-4.75%, P<0.001) in Halcyon, respectively. Significantly reduced low dose spill were observed in Halcyon plans. In the evaluation of the spinal cord, the average of Dmean and V10 of Halcyon plans in the sample group with an overlap volume of less than 1 cc was 6.802 Gy (-3.504%, P=0.067), 5.766±1.683 cc (-8.199%, P=0.002), respectively. Halcyon plans demonstrated statistically significant reduced Dmean and V10. For delivery efficiency, MU and BOT(maximum dose rate for each machine), on average, increased in Halcyon plans. However, the average of BOT(800MU/min for each machine) was 648.33 sec for Halcyon (-1.74%, P<0.001). Conclusion: Halcyon plan for double-target spine SBRT demonstrated advantages in the low dose area with a steep dose gradient, while having dosimetrically equivalent target dose distribution and spinal cord protective effect. As a result, Halcyon LINAC produced a dosimetrically improved plan for double-target spine SBRT.

Atypical Ductal Hyperplasia: Risk Factors for Predicting Pathologic Upgrade on Excisional Biopsy (침생검 조직검사에서 진단된 비정형 관상피증식증: 수술적 절제 생검에서 악성으로 진단될 가능성을 예측할 수 있는 위험인자들)

  • Ko Woon Park;Boo-Kyung Han;Sun Jung Rhee;Soo Youn Cho;Eun Young Ko;Eun Sook Ko;Ji Soo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.632-644
    • /
    • 2022
  • Purpose To determine the incidence of atypical ductal hyperplasia (ADH) in needle biopsy and the upgrade rate to carcinoma, and to evaluate difference in findings between the upgrade and non-upgrade groups. Materials and Methods Among 9660 needle biopsies performed over 48 months, we reviewed the radiologic and histopathologic findings of ADH and compared the differences in imaging findings (mammography and breast US) and biopsy methods between the upgrade and non-upgrade groups. Results The incidence of ADH was 1.7% (169/9660). Of 112 resected cases and 30 cases followed-up for over 2 years, 35 were upgraded to carcinoma (24.6%, 35/142). The upgrade rates were significantly different according to biopsy methods: US-guided core needle biopsy (USCNB) (40.7%, 22/54) vs. stereotactic-vacuum-assisted biopsy (S-VAB) (16.0%, 12/75) vs. USguided VAB (US-VAB) (7.7%, 1/13) (p = 0.002). Multivariable analysis showed that only US-CNB (odds ratio = 5.19, 95% confidence interval: 2.16-13.95, p < 0.001) was an independent predictor for pathologic upgrade. There was no upgrade when a sonographic mass was biopsied by US-VAB (n = 7) Conclusion The incidence of ADH was relatively low (1.7%) and the upgrade rate was 24.6%. Surgical excision should be considered because of the considerable upgrade rate, except in the case of US-VAB.