• Title/Summary/Keyword: Stereo Radiation Image

Search Result 18, Processing Time 0.022 seconds

A Study on Display Data of Radiation Point at 3 Dimensions (3차원 공간상 방사선원 위치 정보 표현에 관한 연구)

  • Lee, Seung-Min;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1130-1132
    • /
    • 2007
  • In this research, 3D position exploring system was developed to detect direction and position of radiation source by using two general CCD camera. This system consists of a radiation detection device, a controlling device, and a monitoring device. A radiation detection device is composed of a collimator, a scintillator, CCD sensor, and radiation shielding part. Incident radiation is firstly collimated with direction and converted into visual lights in a scintillator. The CCD sensor detect the converted visual light and send a signal as an image. This can explore a radiation source with direction and distance from geometrical structure of two sensors. From these information, the developed 3D position exploring system can provide 3D radiation source information. This research will be useful for managing and processing radioactive materials in remote.

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.

Development of underwater 3D shape measurement system with improved radiation tolerance

  • Kim, Taewon;Choi, Youngsoo;Ko, Yun-ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1189-1198
    • /
    • 2021
  • When performing remote tasks using robots in nuclear power plants, a 3D shape measurement system is advantageous in improving the efficiency of remote operations by easily identifying the current state of the target object for example, size, shape, and distance information. Nuclear power plants have high-radiation and underwater environments therefore the electronic parts that comprise 3D shape measurement systems are prone to degradation and thus cannot be used for a long period of time. Also, given the refraction caused by a medium change in the underwater environment, optical design constraints and calibration methods for them are required. The present study proposed a method for developing an underwater 3D shape measurement system with improved radiation tolerance, which is composed of commercial electric parts and a stereo camera while being capable of easily and readily correcting underwater refraction. In an effort to improve its radiation tolerance, the number of parts that are exposed to a radiation environment was minimized to include only necessary components, such as a line beam laser, a motor to rotate the line beam laser, and a stereo camera. Given that a signal processing circuit and control circuit of the camera is susceptible to radiation, an image sensor and lens of the camera were separated from its main body to improve radiation tolerance. The prototype developed in the present study was made of commercial electric parts, and thus it was possible to improve the overall radiation tolerance at a relatively low cost. Also, it was easy to manufacture because there are few constraints for optical design.

The Geometric Modeling for 3D Information of X-ray Inspection (3차원 정보 제공을 위한 X-선 검색장치의 기하학적 모델링)

  • Lee, Heung-Ho;Lee, Seung-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1151-1156
    • /
    • 2013
  • In this study, to clearly establish the concept of a geometric modeling I apply for the concept of Pushbroom, limited to two-dimensional radiation Locator to provide a three-dimensional information purposes. Respect to the radiation scanner Pushbroom modeling techniques, geometric modeling method was presented introduced to extract three-dimensional information as long as the rotational component of the Gamma-Ray Linear Pushbroom Stereo System, introduced the two-dimensional and three-dimensional spatial information in the matching relation that can be induced. In addition, the pseudo-inverse matrix by using the conventional least-squares method, GCP(Ground Control Point) to demonstrate compliance by calculating the key parameters. Projection transformation matrix is calculated for obtaining three-dimensional information from two-dimensional information can be used as the primary relationship, and through the application of a radiation image matching technology will make it possible to extract three-dimensional information from two-dimensional X-ray imaging.

Design and Implementation of an optical wavelength analyzer (CCD 카메라를 이용한 방사선 탐지기의 영상화 기술 연구)

  • Park, Sung-hoon;Park, Jong Won;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.811-813
    • /
    • 2013
  • In order to measure the radiation, there are types of sensors plurality. I was using the detection method and sensitivity of the CCD sensor in the scintillator and collimator in the sensor. In this study, in order to detect radiation using a CCD sensor with high resolution, by measuring the radiation dose by processing the visible light generated in response to radiation of the image coming into the CCD in the scintillator in space it is to present a pointer that radiation comes out most. It is intended to imaging by calculation of the distance to the radiation source to the implementation of the stereo camera system video in the future.

  • PDF

Patient Setup Aid with Wireless CCTV System in Radiation Therapy (무선 CCTV 시스템을 이용한 환자 고정 보조기술의 개발)

  • Park, Yang-Kyun;Ha, Sung-Whan;Ye, Sung-Joon;Cho, Woong;Park, Jong-Min;Park, Suk-Won;Huh, Soon-Nyung
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.300-308
    • /
    • 2006
  • $\underline{Purpose}$: To develop a wireless CCTV system in semi-beam's eye view (BEV) to monitor daily patient setup in radiation therapy. $\underline{Materials\;and\;Methods}$: In order to get patient images in semi-BEV, CCTV cameras are installed in a custom-made acrylic applicator below the treatment head of a linear accelerator. The images from the cameras are transmitted via radio frequency signal (${\sim}2.4\;GHz$ and 10 mW RF output). An expected problem with this system is radio frequency interference, which is solved utilizing RF shielding with Cu foils and median filtering software. The images are analyzed by our custom-made software. In the software, three anatomical landmarks in the patient surface are indicated by a user, then automatically the 3 dimensional structures are obtained and registered by utilizing a localization procedure consisting mainly of stereo matching algorithm and Gauss-Newton optimization. This algorithm is applied to phantom images to investigate the setup accuracy. Respiratory gating system is also researched with real-time image processing. A line-laser marker projected on a patient's surface is extracted by binary image processing and the breath pattern is calculated and displayed in real-time. $\underline{Results}$: More than 80% of the camera noises from the linear accelerator are eliminated by wrapping the camera with copper foils. The accuracy of the localization procedure is found to be on the order of $1.5{\pm}0.7\;mm$ with a point phantom and sub-millimeters and degrees with a custom-made head/neck phantom. With line-laser marker, real-time respiratory monitoring is possible in the delay time of ${\sim}0.17\;sec$. $\underline{Conclusion}$: The wireless CCTV camera system is the novel tool which can monitor daily patient setups. The feasibility of respiratory gating system with the wireless CCTV is hopeful.

A Study on Visual Perception of Hologram Advertisement (홀로그램 매체를 활용한 광고의 시각인지도에 관한 연구)

  • Cho, Yong-Jae
    • The Journal of the Korea Contents Association
    • /
    • v.6 no.12
    • /
    • pp.261-268
    • /
    • 2006
  • A hologram is a three-dimensional image reproduced from a pattern of interference produced by a split coherent beam of radiation. Therefore not only can it express the three dimensional properties of the object, but because of it ability to show the depth and spatial properties of the object holograms may be a more effective tool in advertising for its visual appeal. This study presents 'hologram'a three dimensional stereo imaging, as the expression technique in advertising of the next generation, and with proper understanding of 'hologram' and of all its potential applications discusses opportunities for advertisements that are distinct from the multi media advertisements of today. The basic concept of Holograms and their application methods were presented in the thesis, and by using Sales Promotion advertisement as example, discussed what elements are required in order to produce an effective advertisement using holograms.

  • PDF

Spatial Distribution of Evergreen Coniferous Dead Trees in Seoraksan National Park - In the Case of Northwestern Ridge - (설악산국립공원 상록침엽수 고사목 공간분포 특성 - 서북능선 일원을 대상으로 -)

  • Kim, Jin-Won;Park, Hong-Chul;Park, Eun-Ha;Lee, Na-Yeon;Oh, Choong-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.5
    • /
    • pp.59-71
    • /
    • 2020
  • Using high-resolution stereoscopic aerial images (in 2008, 2012 and 2016), we conducted to analyze the spatial characteristics affecting evergreen coniferous die-off in the northwestern ridge (major distribution area such as Abies nephrolepis), Seoraksan National Park. The detected number of dead trees at evergreen coniferous forest (5.24㎢) was 1,223 in 2008, was 2,585 in 2012 and was 3,239 in 2016. The number of cumulated dead trees was 7,047 in 2016. In recent years, the number of dead trees increased relatively in the northwest ridge, Seoraksan National Park. Among the analysed spatial factor (altitude, aspect, slope, solar radiation and topographic wetness index), the number of dead trees was increased in the conditions with high altitude, steep slope and dry soil moisture. A spatial distribution of dead tree was divided into 2 groups largely (high altitude with high solar radiation, low altitude with steep slope). In conclusion, the dead trees of evergreen coniferous were concentrated at spatial distribution characteristics causing dryness in the northwestern ridge, Seoraksan National Park.