• Title/Summary/Keyword: Step-up and step-down

Search Result 201, Processing Time 0.022 seconds

Transformation Characteristics of Multi layed Ring-dot type Piezo Transformer (적층형 Ring-dot type 압전변압기의 변압특성)

  • Chong, Hyon-Ho;Park, Tae-Gone;Kim, Myong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.671-674
    • /
    • 2004
  • This paper presents design and analysis of multi-layered ring-dot type piezoelectric transformer. These transformers are useful for step up and step down. The transformers consist of disk type multi-layered piezoelectric ceramic plates. The finite element method(FEM) was used for analysis transformer. Vibration mode, electric field and equivalent elastic strain of piezoelectric transformer were simulated by changing frequency. As results, the strain was distributed in isolation part entirely. We can get the operated in step up transformer when the inner side electrode using by input parts. Also we can get the step down transformers using by input Part as outer side electrode. The step up ratio and step down ratio was increased by decreasing inner side electrode. The resonance frequency was increased by increasing inner side electrode when the transformer was operated in step down transformer. But the step up one was decreased. From these results, we can expect to multi-layered ring-dot type piezo transformers as step up and step down transformers.

  • PDF

Effect of Step-up and Step-down Hyperthermia on Skin of Mice (온열요법시 온도변화가 정상조직에 미치는 영향)

  • Choi, Ihl-Bohng;Kim, Choon-Yul;Bahk, Yong-Whee
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.155-161
    • /
    • 1988
  • The usefulness of hypertermia for cancer therapy have well been established. The purpose of the present investigation was to ascess the effect of step-up $(42^{\circ}{\rightarrow}44^{\circ}C$ sequence) and step-down $(44^{\circ}{\rightarrow}42^{\circ}C$ sequence) heating on the skin of the hind foot of the mouse. Hyperthermic treatments were given by immersion the hind foot of the mouse in circulating water baths. Skin response was studied by the leg reaction, which was scored according to a numerical scoring system proposed by Urano et al (1980). The results were as follows 1. The skin damage of $44^{\circ}C$ control group was more severe than $42^{\circ}C$ control group (P<0.05), except for 15 min. heating group. 2. The Skin damage of step-down group was more severe than step-up group (P<0.05). 3. The skin damage of $44^{\circ}C$ control group was more severe than step-up group when there is no difference in $44^{\circ}C$ heating time of step-up group from $44^{\circ}C$ control group (P<0.05). 4. In step-down group, the skin damage was more severe than $44^{\circ}C$ control group after preheating 45 min at $44^{\circ}C$ (P<0.05). Therefore, the above findings suggest the normal tissue damage by step-up heating was correlated with heating time of post step-up. The dropping of heating temperature in late phase had more severe damage of the skin than that in early phase during hyperthermia, and so contineous control of satisfactory temperature should be considered as the one of the most important factor for prognosis, complications of clinical hyperthermia

  • PDF

A study on the Chopper Control System of Electroic Vehicle (전기자동차의 쵸퍼제어 방식)

  • Chung, Y.T.;Han, K.H.;Kim, Y.J.;Lee, S.H.;Kim, D.G.;Lee, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1182-1184
    • /
    • 1992
  • In case of chopper control is used for the d.c motor In the electric vehicle(EV) in general step down chopper is used for the driving and the step-up chopper is used for the regeneration. Bilateral variable ratio chopper system(BVRCS) formed by parallel combination of upper two chopper methods step-down, step-up and step-up/down chopper operations by duty cycle, circuit element and driving condition. In this paper, BVRCS is proposed for the simulated and experimented control of d.c motor in the EV. By the result of simulation BVRCS represents same driving power compared to the step-down and excellent breaking power compared to the step-up chopper system because of the greater motor current.

  • PDF

Effect of Protein Feeding Systems for Egg-type Growing Pullets on Pullet Growth, Nutrient Consumption and Subsequent Laying Performance (난용계 육성기의 단백질 공급체계가 육성계의 성장 및 영양소 섭취량과 산란능력에 미치는 영향)

  • 이규호;정연종
    • Korean Journal of Poultry Science
    • /
    • v.21 no.4
    • /
    • pp.257-266
    • /
    • 1994
  • Three protein feeding systems for egg-type pullets involving conventional step-down protein 18-15-12%), step-up protein(12-15-18%) and single-stage low protein (13-13-13%) with an iso-energy level of 2,900 ME kcal /kg were compared to examine the effect on pullet growth and subsequent laying performance. During the growing period, pullets subjected to the step-up and single-stage low protein feeding systems were lighter in body weight and consumed less feed and netabolizable energy than those on the conventional step-down protein feeding system(P<0.05). 3ut the pullets on the step-up protein diet consumed more protein, and those on the single-stage low protein diet consumed less protein than those on the step-down protein diet(P<0.05). Also, he feed cost was less in pullets on the single-stage low protein diet than in those on the other systems(P<0.05). During the laying period, sexual maturity was later in hens reared on the step-up and single-stage low protein diets than in those on the step-down protein diet(P<0.05), however, average hen-day egg production and egg weight were not significantly affected by the protein feeding systems in the growing period. Daily feed intake and feed required per egg were significantly reduced in hens on the single-stage low protein diet compared to those on conventional protein feeding system(P<0.05). It was concluded that the 13% single-stage low protein feeding system produced smaller pullets with less feed, energy, protein, and feed cost during the growing period, and hens reared on that system consumed less feed during the laying period without any impairment of production compared to the conventional rearing system.

  • PDF

Comparison of Conventional DC-DC Converter and a Family of Diode-Assisted DC-DC Converter in Renewable Energy Applications

  • Zhang, Yan;Liu, Jinjun;Ma, Xiaolong;Feng, Junjie
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.203-216
    • /
    • 2014
  • In the conventional dc-dc converter, a pair of additional diode and the adjacent passive component capacitor/inductor can be added to the circuit with an X-shape connection, which generates a family of new topologies. The novel circuits, also called diode-assisted dc-dc converter, enhance the voltage boost/buck capability and have a great potential for high step-up/step-down power conversions. This paper mainly investigates and compares conventional dc-dc converter and diode-assisted dc-dc converter in wide range power conversion from the aspects of silicon devices, passive components requirements, electro-magnetic interference (EMI) and efficiency. Then, a comprehensive comparison example of a high step-up power conversion system was carried out. The two kinds of boost dc-dc converters operate under the same operation conditions. Mathematical analysis and experiment results verify that diode-assisted dc-dc converters are very promising for simultaneous high efficiency and high step-up/step-down power conversion in distributed power supply systems.

Research on a New 12-Pulse Step-Up and Step-Down Aviation Auto-Transformer Rectifier

  • Jiang, Fan;Ge, Hong-juan;Dong, Xiao-xu;Zhang, Lu
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.266-276
    • /
    • 2018
  • This paper presents a new step-up and step-down multi-pulse auto-transformer rectifier unit (ATRU) topology. This structure can achieve a wide range of output voltages, which solves the problem of auto-transformer output voltage being difficult to regulate. Adding middle taps to the primary winding and reasonably setting the number of auto-transformer windings, constituted two groups of three-phase output voltages with a $30^{\circ}$ phase difference. Multi-pulse output DC voltage is obtained after a three-phase output voltage across two rectifier bridges and inter-phase reactor. Thus, the output DC voltage is related to the number and configuration of the auto-transformer winding. In this paper, the relationship between the voltage ratio of the auto-transformer and the ratio of winding, input current and auto-transformer kilovoltampere rating are deduced and validated by simulations. On this basis, the output voltage range is optimized. An experiment on two different voltage ratio principle prototypes was carried out to verify the correctness of the analysis design.

Low-Cost High-Efficiency Two-Stage Cascaded Converter of Step-Down Buck and Tapped-Inductor Boost for Photovoltaic Micro-Inverters (태양광 마이크로 인버터를 위한 탭인덕터 부스트 및 강압형 컨버터 캐스케이드 타입 저가형 고효율 전력변환기)

  • Jang, Jong-Ho;Shin, Jong-Hyun;Park, Joung-Hu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.157-163
    • /
    • 2014
  • This paper proposes a two-stage step-down buck and a tapped-inductor boost cascaded converter for high efficiency photovoltaic micro-inverter applications. The proposed inverter is a new structure to inject a rectified sinusoidal current into a low-frequency switching inverter for single-phase grid with unity power factor. To build a rectified-waveform of the output current. the converter employs both of a high efficiency step-up and a step-down converter in cascade. In step-down mode, tapped inductor(TI) boost converter stops and the buck converter operates alone. In boost mode, the TI converter operates with the halt of buck operation. The converter provides a rectified current to low frequency inverter, then the inverter converts the current into a unity power-factor sinusoidal waveform. By applying a TI, the converter can decrease the turn-on ratios of the main switch in TI boost converter even with an extreme step-up operation. The performance validation of the proposed design is confirmed by an experimental results of a 120W hardware prototype.

A study on control strategy of power factor correction for AC-DC power conversion system (AC-DC 전력변환기의 역률개선 제어기법에 관한 연구)

  • Kwak Dong-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.263-266
    • /
    • 2003
  • The high power factor converters are classified step-up, step-up-down and step-down converter, The power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. And the power system brings on a high efficiency and high power factor. When a switch of the step down converter is operated with a commercial frequency(60Hz), a reactor using the converter is gone with a great number of harmonics waveforms of low grade. As results of this, the converter is decreased input power factor and is increased system size. To improved these, this paper proposes a PSM(Pulse Size Modulation) control strategy operated with high power factor.

  • PDF

Single-Phase Z-Source Matrix Converter (SZMC) with Output Voltage Boost Capability

  • Nguyen, Minh-Khai;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.234-237
    • /
    • 2008
  • This paper deals with a new single-phase Z-source matrix converter (SZMC) topology. Unlike other conventional configurations, the proposed SZMC is not only a step-up frequency converter but also a step-down frequency converter and a voltage boost capability. Thus, the proposed SZMC is also called a frequency step-up/down and voltage step-up converter. A safe-commutation strategy is used in SZMC as free-wheeling operation to eliminate voltage spikes on switches. The operating principles and experimental results of the proposed SZMC are presented.

  • PDF

Setting Up/Down Step-Size in Open Loop Power Control for WiBro Reverse Link (와이브로 상향링크에서 개방형 전력제어를 위한 상/하향 전력제어 계단값 설정 방법)

  • Guk, Hyun;Kim, Jung-Bin;Kim, Dong-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7A
    • /
    • pp.686-693
    • /
    • 2007
  • In this paper, we describe how to set up/down step-size in open loop power control for WiBro reverse link. Since open loop power control does not use feedback information, it is difficult to efficiently use wireless resource with accurate power control. We also provides a method of estimating levels of noise and interference. With numerical investigation, asymmetric up/down power-control step-size is shown to be promising to achieve high sector throughput as well as low error rate.