• Title/Summary/Keyword: Step pulse

Search Result 365, Processing Time 0.024 seconds

Design of Microprocessor Embedded 2-Axis Motor Control Chip (Microprocessor Embedded 2-Axis Motor Control Chip의 설계)

  • Roh, Kyu-Jin;Choi, Sung-Hyuk;Won, Jong-Baek;Kim, Jong-Eun;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.193-196
    • /
    • 2001
  • In this paper we designed CAMC-SP, the microprocessor embedded 2-axis motor control chip which controls a precise pulse motor by generating the pulse needed to control step motor, DC servo and AC servo motor. This design enables to decrease costs and to minimize a size. First we designed risc type 8-bit microprocessor compatible with PIC16C84, second we designed pulse motor controller. CAMC-SP is integrated of those two block. We designed CAMC-SP by VHDL and we testified to the Performance of it by performing functional simulation.

  • PDF

Energy transfer and photon avalanche in Tm3+:LaF3

  • Yoo, Mi-Oh;Lim, Ki-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.10-14
    • /
    • 1997
  • Single pulse laser excitation at 656 nm and successive pulse excitation at 635.2 and 648.4 nm produced blue emission at 480 nm by two-step upconversion process in Tm/sup 3+/:LaF/sub 3/. The excited-state absorption cross-section of the /sup 3/F/sub 4/ to /sup 1/G/sub 4/ transition was estimated by a looping mechanism with cross-relaxation processes. The dynamics of up-conversion andthe possibility of the photon avalanche by a pulse laser excitation were studied by numerical simulation with the rate equation model.

Calculation of Equivalent Inductance Variation for Position Detection of Linear Pulse Motor (리니어 펄스 모터의 위치검출을 위한 등가인덕턴스변화량 연산기법)

  • Kim, Sung-Heon;Lee, Eun-Woong;Lee, Dong-Ju;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.15-17
    • /
    • 1998
  • The position of LPM's mover can be estimated by the equivalent inductance variation with the mover's displacement. Hence, in this paper, we obtained the position detection signal by the calculation of equivalent inductance variation using the winding of linear pulse motor. And the various parameters for calculation of equivalent inductance variation were obtained by the design specification and finite element analysis of linear pulse motor. With this position signal, it is possible to calculate the driving numbers of steps, to confirm the state of step out and to determine the optimal switching angle, etc.

  • PDF

Modulated Pulsed Power를 이용한 Cr 박막의 증착과 특성 분석

  • Min, Gwan-Sik;Song, Je-Beom;Yun, Ju-Yeong;Sin, Yong-Hyeon;Cha, Deok-Jun;Hwang, Yun-Seok;Heo, Yun-Seong;Kim, Jin-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.123.1-123.1
    • /
    • 2013
  • 반도체 공정에서는 사용하는 power source의 형태는 pulse-DC이다. Pulse-DC는 DC power에 비해 증착율이 좋고, 박막의 특성도 우수한 특성을 가진다. 이러한 장점에도 불구하고 pulse-DC나 DC power는 플라즈마 내 이온이 가지는 에너지가 크고, 이온화율도 낮다. 이러한 단점을 극복하기 위해 등장한 power source가 modulated pulsed power이다. Modulated pulsed power는 이온이 가지는 에너지가 DC power의 1/2 수준이며, 이온화율은 4배 이상 높은 특징을 가진다. 본 연구에서는 modulated pulsed power를 사용하여 Cr 박막을 Si wafer 위에 증착하여 박막의 특성을 관찰하였다. 연구에 사용된 power는 5 kV (800 V, 12.5 A), 20~120 KHz, 3 step까지 설정이 가능한 장비이며, base pressure $1.5{\times}10^{-6}$ Torr에서 실험이 진행되었고, 실험에 사용된 불활성 기체는 Ar을 사용하였다.

  • PDF

A Study on the Environmental Hormone

  • Chil Nam, Choi;Eun Jung, Na
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.05a
    • /
    • pp.193-194
    • /
    • 2001
  • To determine for the hybridization, we have investigated by UV spectroscopic method. This complex behavior as nonelectrolytes in polar aprotic solution with molar conductivities. The technoques of pulse and cyclic voltammetry have been applied to the determination of $(E_{1/2})_{2}$-$(E_{1/2})_{1}$ for two-step electrochemical charge transfers. A simple amplitude has been derived for the dependence of the differential-pulse response on $(E_{1/2})_{1}$ and $(E_{1/2})_{2}$. The use of the peak-to-peak separation in cyclic voltammetry has also been evaluated. Comparison with a differential pulse and cyclic voltammetry methods shows agreement of comproportionation constant$(K_{c})$ within 50%.

  • PDF

Clinical Study of the Floating-Sinking Pulse Quantification Analysis on Ages, Left/Right, and Palpation Positions (20/60대 여성을 중심으로 살펴본 좌우 촌관척 부/침맥 정량화 임상연구)

  • Kim, Jae-Uk;Kim, Sung-Hun;Jeon, Young-Ju;Ryu, Hyun-Hee;Lee, Yu-Jung;Lee, Hae-Jung;Kim, Jong-Yoel
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1193-1198
    • /
    • 2009
  • Pulse diagnosis is a central diagnosis method used in traditional Oriental medicine. To standardize and modernize the pulse diagnosis method, it is essential to develop an instrument-based reinterpretation of the clinically used pulse images in terms of the physical quantities such as the strength, period, width, length, and depth of the pulse. As a step towards such standardization, we conducted a clinical study on the floating/sinking pulses based on an automated palpation instrument (3D-MAC, Daeyo Medi, Korea) for 213 female subjects in their 20s and 174 female subjects in their 60s. The floating/sinking pulses are the two representative pulse images depending only on the depth of the pulse, and can be conveniently scaled by the coefficient of the floating-sinking pulse ($C_{fs}{\in}(0,1)$), which represents how strong one should apply the hold-down pressure to obtain the maximal pulse strength. As a result, primarily we found that it tends to appear more floating-like pulse ($C_{fs}{\rightarrow}0$) at Gwan and more sinking-like pulse ($C_{fs}{\rightarrow}1$) at Cheek, at both age groups and at both wrists. This result is consistent with a previous study on the geometrical structure of the blood vessel by an ultrasonograph. Second, the pulse tends to be more sinking-like in the age group of 60s than 20s. Finally, the pulses at the right palpation positions were found to be more sinking-like than the left, at both age groups.

Sinusoidal A Study on the gain Stability of the Feedback Linear Pulse Amplifiers for Fast Pulse Input (금속펄스 선형증폭기의 빠른 입력펄스에 대한 이득안정도에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.3
    • /
    • pp.1-14
    • /
    • 1974
  • The gain stability of the nuclear pulse linear amplifiers with feedback for such a fast pulse input as the step voltage or the nuclear radiation detector pulse is analysed in detail. The expression is derived which describes the waveform at the anode circuit of the photomultiplier tube which is a part of the nuclear radiation detector. It is analysed and compared when the feedback amplifier has one and two time-constants. When these fast input pulse voltages are applied to the feedback amplifier, the effects of feedback in linearity and stability of the output voltage appear only after two or three rise-times of the amplifier, And it is proved that in order to reduce this limitation, the rise time of the feedback amplifier shou1d be less than the input pulse width. It is also shown that the above theory can be applied directly to the voltage-shunt feedback amplifier stages designed as the basic amplifier of the linear amplifier, and that the gain stability is more improved for the smaller input impedance of this amplifier stage.

  • PDF

Midinfrared Pulse Compression in a Dispersion-decreasing and Nonlinearity-increasing Tapered As2S3 Photonic Crystal Fiber

  • Shen, Jianping;Zhang, Siwei;Wang, Wei;Li, Shuguang;Zhang, Song;Wang, Yujun
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.250-260
    • /
    • 2021
  • A tapered As2S3 photonic crystal fiber (PCF) with four layers of air holes in a hexagonal array around the core is designed in this paper. Numerical simulation shows that the dispersion D decreases and the nonlinearity coefficient γ increases from the thick to the thin end along the tapered PCF. We simulate the midinfrared pulse compression in the tapered As2S3 PCF using the adaptive split-step Fourier method. Initial Gaussian pulses of 4.4 ps and a central wavelength of 2.5 ㎛ propagating in the tapered PCF are located in the anomalous dispersion region. With an average power of assumed input pulses at 3 mW and a repetition frequency of 81.0 MHz, we theoretically obtain a pulse duration of 56 fs and a compression factor of 78 when the pulse propagates from the thick end to the thin end of the tapered PCF. When confinement loss in the tapered PCF is included in the simulation, the minimum pulse duration reaches 72 fs; correspondingly, the maximum compression factor reaches 61. The results show that in the anomalous-dispersion region, midinfrared pulses can be efficiently compressed in a dispersion-decreasing and nonlinearity-increasing tapered As2S3 PCF. Due to confinement loss in the tapered fiber, the efficiency of pulse compression is suppressed.

An Identification Method of Radar Signals using Parallel Processor (병렬프로세서를 활용한 레이더 신호의 식별)

  • Kim, Gwan-Tae;Ju, Young-Kwan;Park, Sang-Hwan;Jeon, Joongnam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.75-80
    • /
    • 2017
  • ES (Electronic Warfare Support System) collects radar signals, and analyzes the signals about frequency, pulse width, PRI (Pulse Repetition Interval), and etc. and then ES compares analyzed result with known radar signals to identify them. But there are two disadvantage. One is that use of known radar signals is in comparing step only. The other is that calculating PRI needs many operations. In this paper proposes a parallel reference correlation algorithm that uses GPGPU (General Purpose Graphics Processing Units) and can identify what signals are in received radar signals without calculating PRI.

The Digital Controlled Implementation of the Resonant DC-DC Converter with High Voltage, High Frequency For Pulsed Nd:YAG Laser (고전압과 고주파수형 공진형 DC-DC 콘버터를 이용한 펄스형 Nd:YAG 레이저의 디지틸제어 구현)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.777-783
    • /
    • 2001
  • This paper is mainly concerned with the state of the practical developments of a constants PWM bridge type resonants DC-DC suitable converter for Nd:YAG Laser with a Microprocessor. (PIC16C54 & 8051) The use of IGBT power supply with feedback control of flashLamp currents imparts a advantages to Nd:YAG Laser for materials processing. these include the alility to tailor the pulseshape and modify pulse parameters on a pulse- by pulse basis. And Correct choice of pulseshape can enhance the repeatability of the process. as higher power IGBT became available, act ive pulseforming power supplies will find greater user in deep hole drilling machine By Using certain control tecniques, utililized in designing Pic16c54 from Microchip technology and Intel 8051, also Mornitoring from Microsoft Visual Basic 5, And it allowed us to designed and fabricate ahigh repel it ion rate and high power(HRHP) pulsed Nd:YAG laser system, As a result of that, the current pulsewidth could be contort led 200s to 350s(step 50s) , and the pulse repetition rate could be adjusted 500pps to 1150pps. In addition, in the case of one laser head consisting of a Nd:YAG laser rod and two flashlamps , the maximum laser output of 240w was produced at the condition of 350s and 1150pps, and that of about 480w was generated at the same condition when two laser heads were arranged in cascade.

  • PDF