• Title/Summary/Keyword: Step motor

Search Result 660, Processing Time 0.028 seconds

Text Classification Using Parallel Word-level and Character-level Embeddings in Convolutional Neural Networks

  • Geonu Kim;Jungyeon Jang;Juwon Lee;Kitae Kim;Woonyoung Yeo;Jong Woo Kim
    • Asia pacific journal of information systems
    • /
    • v.29 no.4
    • /
    • pp.771-788
    • /
    • 2019
  • Deep learning techniques such as Convolutional Neural Networks (CNNs) and Recurrent Neural Networks (RNNs) show superior performance in text classification than traditional approaches such as Support Vector Machines (SVMs) and Naïve Bayesian approaches. When using CNNs for text classification tasks, word embedding or character embedding is a step to transform words or characters to fixed size vectors before feeding them into convolutional layers. In this paper, we propose a parallel word-level and character-level embedding approach in CNNs for text classification. The proposed approach can capture word-level and character-level patterns concurrently in CNNs. To show the usefulness of proposed approach, we perform experiments with two English and three Korean text datasets. The experimental results show that character-level embedding works better in Korean and word-level embedding performs well in English. Also the experimental results reveal that the proposed approach provides better performance than traditional CNNs with word-level embedding or character-level embedding in both Korean and English documents. From more detail investigation, we find that the proposed approach tends to perform better when there is relatively small amount of data comparing to the traditional embedding approaches.

Correlation between Pediatric Balance Scale and Gait Parameter in Children with Spastic Diplegic Cerebral Palsy (경직성 양하지 뇌성마비 아동의 소아균형검사와 보행변수 간의 상관관계)

  • Ko, Myung-Sook;Park, So-Yeon;Lee, Nam-Gi
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.251-257
    • /
    • 2016
  • The Pediatric Balance Scale (PBS) was balance measurement equipment for school-age children with mild to moderate motor impairments. The aims of this study are to examine the correlation between PBS and spatiotemporal gait parameter and to identify the walking function with cerebral palsy through balance scale. The PBS consists of 14 items such as sitting of standing, standing to sitting, transfers, standing unsupported, standing on one foot, turning 360 degrees, turing to look behind, etc., and the spatiotemporal parameters include walking speed, stride length, step length, step width, cadence, double-limb support. All subjects were independently ambulatory children with spastic diplegic cerebral palsy, and they were assessed on PBS and spatiotemporal gait parameters by an experienced pediatric physical therapist. Pearson's correlation coefficient was used to assess the correlation between PBS and spatiotemporal gait parameters, and the level of significance was set at ${\alpha}$ = 0.05. Total score of PBS(r=.49~.58), standing to sitting(r=.48~.60), turning to look behind(r=.47~.53), and pick up object(r=.52~.69) were positively correlated with walking speed, stride length, step length, and cadence. Most items of the PBS were negatively correlated with double-limb support(r=-.48~-.92). These findings suggest that the pediatric balance scale can be applied to estimate gait function level for children with spastic diplegic cerebral palsy.

Numerical Stability of Serial Staggered Methods in Fluid-Structure Interaction Analysis of Solid Rocket Motors (고체추진기관의 유동-구조 상호작용 해석에서 Serial Staggered 기법의 수치 안정성)

  • Cho, Hyun-Joo;Lee, Jee-Ho;Lee, Chang-Soo;Kim, Chong-Am;Kim, Shin-Hoe;Lee, Jeong-Sub
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.2
    • /
    • pp.179-185
    • /
    • 2016
  • In this paper numerical stability of CSS and ISS schemes in axisymmetric fluid-structure-burning simulation for solid rocket motors are studied. The implemented CSS and ISS algorithms for two-dimensional axisymmetric FSI problems are used to analyze ACM and BCM solid rocket motors. Numerical results from CSS and ISS schemes are compared to investigate the efficacy of ISS scheme over CSS scheme in stabilizing the numerical solution. The ACM and BCM simulation results show that ISS scheme gives stable and converged numerical solutions with appropriately small system time step size, while CSS scheme fails to converge after generating rapidly amplified oscillatory solutions. It is concluded that ISS scheme can be useful in improving the numerical stability of FSI analysis for ACM and BCM solid rocket motor simulations, which is not successfully obtained with CSS scheme.

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

Developing a Scale for Measuring the Constraints in Physical Activity of People with Physical Disabilities - Verification of Factor Structure and Related Criterion Validity - (지체장애인의 운동참여제약 측정척도 개발 -요인구조 탐색과 준거관련타당도 검증-)

  • Seo, Eunchul;Baek, Jae keun
    • 재활복지
    • /
    • v.21 no.1
    • /
    • pp.253-277
    • /
    • 2017
  • The purpose of this study was to develop the Constraints in Physical Activity Scale for people with physical Disabilities(CPASD) which measures the constraints in physical activity of people with physical disabilities. For this study, the 5 step analytic framework of unified validity developed by Messick (1995), the framework for conducting a strong program of construct validation by Benson (1998) method were applied. Furthermore, the validity of CPASD was systematically presented by applying common factor model and measurement model to 264 persons with physical disabilities. The conclusion based on the results and discussions of this study is as follows. First, CPASD presented evidence of job validity. Four factors (17 items) were developed, consisting of leader constraints, economic constraints, prejudice, and exercise environment constraints through the analysis of the factor structure and the fit of factor coefficients. Second, the factor structure of the developed CPASD (leader constraint, economic constraint, prejudice, exercise environment constraint) was statistically distinguished and stably reflected the existing exercise participation constraints theory. Third, the developed CPASD presented evidence of the validity of the criteria. Leader constraints and prejudice were negatively correlated with positive motor emotions, leader constraints, prejudice, and exercise environment constraints were positively correlated with negative motor emotions. Therefore, in future research, it is necessary to reevaluate the current system and actual condition related to leader constraints, economic constraints, prejudices, and exercise environment constraints derived as factors of CPASD. To do this, it is necessary to judge the degree of reality based on the causal relationship verification and IRT theory using CPASD.

Effects of Czech get up Exercise on Functional Movement and Dynamic Balance in Female Office Worker

  • Kim, Chan-Yang;Lee, Jin-Wook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.5
    • /
    • pp.215-224
    • /
    • 2022
  • The purpose of this study is to analyze how it affects functional movement and dynamic balance applying Czech get up exercise based on the principle of motor development of child for office worker women in 30s and 40s. Through random allocation, an Czech get up exercise group(n=15) and a control group(n=14) were formed to apply exercise for 12 weeks, 3 times a week, and 60 minutes a day, and the control group maintained daily life at the same period. As a result of the study, showed that Deep squat(p<.05), Hurdle step(p<.01), In-line lunge(p<.05), Trunk stability push-up(p<.001), Rotary stability (p<.01), Total score(p<.001), were significantly in the Czech get up Group, and Dynamic Balance of Lower Extremity(p<.001), Right Dynamic Balance of Lower Extremity(p<.001) were also significantly in the Czech get up Group. In conclusion, it is thought that Czech get up exercise based on the principle of motor development of child will have a positive effect on the functional movement and dynamic balance in office women, thereby increasing work efficiency as well as healthy life.

Forging Die Design for Vent Forming of Square Cup Battery Case (사각 컵 배터리 케이스 바닥 벤트 성형을 위한 단조 금형 설계)

  • Lee, Sang-Hoon;Kwon, Soon-Ho;Chung, Hoon;Hong, Seokmoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.330-335
    • /
    • 2017
  • The demand for electric motor fuel cells has surged in the automotive industry, leading to a recent increase in the demand for square aluminum cans used as fuel cell battery casings. The air vent located on the bottom of the rectangular battery casing prevents large explosions by intermittent pressure release prior to the accumulation of abnormally high pressures. Conventionally, the square cup battery casing is produced via six-step deep drawing, with the outer shape of the vent being manufactured by welding to the square battery casing. On the other hand, this study directly incorporated the air vent outlet into the bottom surface of the rectangular casing. The product of a coupled finite element analysis technique applying the thickness and contour generated from the square cup multi-step deep drawing formation analysis was used as the forging input shape. The results yielded increased prediction accuracy and the advanced prediction of defects, such as swelling and fracture. Based on the results of the initial analyses, two of the generated forging shapes were determined to be suitable, with the optimal forging shape being determined by molding analysis. The results presented here were validated by mold fabrication and a subsequent comparison of the actual and analytical results.

Experimental Study on the Control Characteristics of Each Channel in a Semiconductor Chiller (반도체 공정용 칠러의 채널별 제어특성에 관한 실험적 연구)

  • Kim, Hyeon-Joong;Kwon, Oh-Kyung;Cha, Dong-An;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1285-1292
    • /
    • 2011
  • The characteristics of a semiconductor chiller system with EEV have been experimentally studied. Three experiments on temperature changes (increase and decrease), load variation, and control precision were conducted to investigate the operating characteristics of the semiconductor chiller. The power consumption was 8.9 kW during increase in temperature. The required time was 37.5 min for CH1 and 39.5 min for CH2. Moreover, the time required for falling temperature was 26.5 min. The control precision for partial load operation was relatively low compared to that of a full load operation. In addition, the CH2 equipped with a step motor showed better control precision. The power consumed by the chiller for process cooling water was 1.8 kW, which was one-half of that consumed during the refrigeration cycle. The objective of this study is to provide an optimal control guideline for the semiconductor chiller design.

Discriminant and predictive validity of TUG, F8WT, FSST, ST for community walking levels in chronic stroke survivors (만성 뇌졸중 환자들의 지역사회 보행 수준 구별을 위한 일어나 걸어가기 검사, 8자 모양 경로 보행 검사, 네 막대 스텝 검사, 스텝 검사의 변별력과 예측 타당도)

  • Lee, DongGeon;An, SeungHeon;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.2
    • /
    • pp.25-35
    • /
    • 2020
  • Background: There are many situations where walking in an actual community needs to change direction along with walking on a straight path, and this situation needs to be reflected in assessing walking ability of the community. Therefore, in this study, we tried to determine whether the assessments can distinguish the level of walking in the community. Design: Retrospective cohort study. Methods: Fifty-two survivors with chronic stroke have participated in the study. According to the evaluation result of 10mWT, the subjects of 0.8m/s and above were classified as the group who could walk in the community (n=22), and the subjects of 0.4m/s~0.8m/s were classified into the group who could not walk in the community (n=30). Modified Rivermead Mobility Index, Postural Assessment Scale for Stroke, Fugl-Meyer Assessment, Berg Balance Scale, 10-meter Walk Test (10mWT) were used to evaluate the motor skills. Furthermore, Activities-specific Balance Confidence Scale was used to evaluate psychological factors, and Timed Up & Go Test (TUG), Figure-of-Eight Walk Test (F8WT), Four Square Step Test (FSST), Step Test (ST) were applied to evaluate dynamic balance and mobility. Results: As a result for distinguishing walking levels in the community, TUG was 14.25 seconds, F8WT was 13.34 seconds, FST was 19.43 seconds, and ST of affected side and non-affected side were 6.5 points and 7.5 points, respectively. TUG (AUC=0.923), F8WT (AUC=0.905), and FST (AUC=0.941) were highly accurate, but the ST of affected side and non-affected side (AUC=0.806, 0.705) showed the accuracy of the median degree, respectively. Conclusion: To distinguish walking levels in the community of survivors with chronic stroke, TUG and FSST have been found to be the best assessment tool, and in particular, FSST could be very valuable in clinical use as the most important assessment tool to distinguish walking levels in the community.

Effects of Saenghyetang on Learning and Memory Performances in Mice (생혜탕(生慧湯)이 흰쥐의 학습(學習)과 기억(記憶)에 미치는 영향(影響))

  • Yu Geum-Ryoung;Chang Gyu-Tae;Kim Jang-Hyeon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.77-104
    • /
    • 2001
  • The effects of the oriental herbal medicine Saenghyetang(SHT, 生慧湯), which consists of Rehmanniae Radix (熟地黃 九蒸: was made by 9th steam) 40g, Corni Fructus(山茱黃) 16g, Polygalae Radix(遠志) 8g, Zizyphi Spinosae Semen(酸棗仁) 2g, Biotae Semen(柏子仁 去油: oil ingredient was removed) 20g, Poria Cocos(茯笭) 12g, Ginseng Radix(人蔘) 12g, Acori Graminei Rhizoma(石菖蒲) 2g, Sinapis Semen(白芥子) 8g, on learning ability and memory were investigated. Hot water extract(HWE) and ethanol extract(EE) from SHT were used for the studies. Learning ability and memory are related to modifications of synaptic strength among neurons that interactive. Enhanced synaptic coincidence detection leads to improved learning ability and memory. If the NMDA receptor, a synaptic coincidence detector, acts as a graded switch for memory formations, enhanced signal detection by NMDA receptors should enhance learning ability and memory. It was shown that NR2B was increased in the forebrains of oriental medicine-administrated mice, leading to enhanced activation of NMDA receptors and facilitating synaptic potentiation in response to stimulation at 10-100 Hz. These HWE-SHT treated mice exhibited that superior ability in learning and memory when performing various behavioral tasks, showing that NR2B is enhanced by HWE-SHT treatment and also is critical in gating the age-dependent threshold for plasticity and memory formation. NMDA receptor-dependent modifications, which were mediated in part by HWE administration, of synaptic efficacy, therefore, represent a mechanism for associative learning ability and memory. Results suggest that oriental medical enhancement of NR2B contributes to increase intelligence and memory in mammals On the other hand, to examine the effects of EE-SHT on the learning ability and memory in experimental mice, EE-SHT was tested on passive and active avoidance responses. The EE-SHT ameliorated the memory retrieval deficit induced by ethanol in mice, but not other memory impairments. EE-SHT(10, 20mg/100 g, p.o.) did not affect the passive avoidance responses of normal mice in the step through and step down tests, the conditioned and unconditioned avoidance responses of normal mice in the shuttle box, lever press performance tests and the ambulatory activity of normal mice in a normal condition. However, EE-SHT at 20 mg/kg significantly decrease the spontaneous motor activity during the shuttle box test, and also to extend the sleeping time induced by pentobarbital in mice. These results suggest that SHT has an ameliorating effect on memory retrieval impairments and a weak tranquilizing action.

  • PDF