• Title/Summary/Keyword: Step height

Search Result 473, Processing Time 0.026 seconds

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • v.77 no.6
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.

Mechanical Characteristics of Cementing Plane in Concrete Repair under Various Cementing Conditions (접합조건에 따른 콘크리트 접합부의 역학적 특성)

  • 김재동;정요훈
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.362-372
    • /
    • 2003
  • Since the occurrence of Portland cement, a great number of concrete structures were constructed. But the concrete structures have their own life times, which inevitably demand repairing treatments, especially on their surface parts. Currently many various methods have been developed and are being applied fer this purpose. In this study, a newly developed method using pneumatic chipping machine and anchor pin was adopted far repair of old concrete structure and the mechanical characteristics of cementing plane between existing and new concrete were tested. Comparing the removal methods for the decrepit part of existing concrete using pneumatic chipping machine and hydraulic breaker, the peak cohesion was higher when using chipping machine at the cementing plane. On the other hand, the residual cohesion was higher for the case of breaker. Step shaped chipping on the cementing plane was effective in increasing peak cohesion, which results 14% increase in the case of 30 mm step height and 22% in 50 mm height when compared with planar chipping plane. The use of anchor pin increased the residual cohesion, which restricted shear slip on the cementing plane after peak shear stress and the tensile strength of 32% compared with that of non-anchored case. According to the combined effect of step shaped chipping of 30 mm and anchor pin with an interval of 15 cm, the peak cohesion reached up to 77% and the residual cohesion showed 180% of the ones of the fresh concrete, respectively.

Analysis of The Human Thermal Environment in Jeju's Public Parking Lots in Summer and Suggestion for Its Modification (제주시 공영 주차장 내 여름철 인간 열환경 분석 및 저감 방안 제안)

  • Choi, Yuri;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.3
    • /
    • pp.18-32
    • /
    • 2024
  • This study aims to analyze the summer human thermal environment in Jeju City's outdoor parking lots by measuring microclimate data and comparing pavement and vegetation albedoes and elements through computer simulations. In measured cases, results due to albedo showed no significance, but there was a significant difference between sunny and shaded areas by trees. The sunny area had a PET (physiological equivalent temperature) in the 'very hot' level, while the shaded area exhibited a 2-step lower 'warm' level. UTCI (universal thermal climate index) also showed that the sunny area was in the 'very strong heat stress' level, whereas the shaded area was 1-step lower in the 'strong heat stress' level, confirming the role of trees in reducing incoming solar radiant energy. Simulation results, using the measured albedoes, closely resembled the measured results. Regarding vegetation, scenarios with a wide canopy, high leaf density, and narrow planting spacing were effective in mitigating the human thermal environment, and the differences due to tree height varied across scenarios. The scenario with the lowest PET value was H9W9L3D8 (tree height 9m, canopy width 9m, leaf area index 3.0, planting spacing 8m), indicating a 0.7-step decrease compared to the current landscaping scenario. Thus, it was confirmed that, among landscaping elements, trees have a significant impact on the summer human thermal environment compared to ground pavement.

Experimental Study on Flow Characteristic and Wave Type Flow at Downstream of Stepped Weir (계단형 보 하류 흐름특성과 Wave Type Flow에 관한 실험연구)

  • Kang, Joon-Gu;Yeo, Hong-Koo;Lee, Keum-Chan;Choi, Nam-Jeong
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.1
    • /
    • pp.41-49
    • /
    • 2010
  • Stepped weir of this study was suggested a type of natural type structures. Unique flow, such as Wave type flow, at downstream of mild slope stepped occurs. WTF(Wave type flow) is different with hydraulic jump occurred at Round crest weir. WTF is phenomenon to rise the water level by recirculation area occurred by step height at downstream of mild slope stepped. Wave height of WTF condition is higher than tailwater level and maximum velocity of WTF condition occurs in area of water surface. In this results, WTF presents to be important factor for design of join area of weir with levee. This study got and analyzed hydraulic condition occurred of WTF, scales of WTF and velocity profiles on flow patterns using experiments. WTF was not consider to stepped weir design and this results can be important data for design of stepped weir and structures.

Evaluation on Non-liturgical Space of Catholic Churches from the Perspective of Universal Design - Focused on 6 Cases in Busan Parish - (유니버설 디자인 관점에서 성당 비전례공간 평가 - 부산교구 6개 사례를 중심으로 -)

  • Cho, Youn-Joo;Nam, Kyung-Hwa;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.3
    • /
    • pp.38-47
    • /
    • 2015
  • This study evaluated non-liturgical space of catholic churches based on the four principles of universal design; accessible design, supportive design, safety-oriented design, and adaptable design. To design those spaces in terms of supportive design principle, diaper exchanging station needs to be placed in the restroom. Findings of this study are as follows: In terms of accessible design, valid width of entrance door to each room(more than 800mm), installation of elevator, height of riser in the stair, and width of step board were appropriate, but there were many spaces where door sils were not removed. In terms of supportive design, notice board at teacher's room and installation of storage closet, and width of passage to office(more than 1,200mm) were also appropriate, but storage closet at a meeting and prayer room, and space for storing flowers appeared inappropriate. To design those spaces in terms of supportive design principle, diaper exchanging station needs to be placed in the restroom. In terms of safety-oriented design, installation of round-edged furniture, use of non-slip flooring material, installation of safety emergency bell at a restroom, and installation of wall handle were required. In terms of adaptable design, space for wheelchair users at each room, installation of the furniture that can adjust the height, installation of desk with different height at an office, installation of toilet and basin considering children were considered to be necessary.

Nipple reconstruction using the C-V flap technique after breast reconstruction with the only breast expander (유방확장기만을 사용한 유방재건술 후 C-V 피판을 이용한 유두재건술)

  • Song, Jea Yong;Han, Byung Kee;Kim, Chung Hun
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.422-427
    • /
    • 2009
  • Purpose: Breast cancer is second most common cancer in women. Almost of patients with breast cancer treated with mastectomy undergoes breast reconstruction. Nipple reconstruction is an important step in breast reconstruction. Many surgeons have investigated of nipple reconstruction using the flap technique after breast reconstruction with the autologous tissue. The objective of this study is to evaluate the results of nipple reconstruction using the C - V flap technique after breast reconstruction with the only breast expander. Methods: From April 2006 to May 2008, the authors treated 17 patients of nipple reconstruction using C - V flap technique, who were received breast reconstruction with the only breast expander. We have predicted decrease of the size of reconstructed nipple and designed flap a little larger than wanted nipple size. Nipple splint was applied for 4 - 6 months for minimizing decrease of the size of reconstructed nipple. The diameter and height of the reconstructed nipple were measured and patient's satisfaction score was assessed. Results: Mean follow-up duration was 12.5 months. Among the 17 patients, the average absorption rate by height of nipple was 47.0%. Partial necrosis was noted in 1 case, and treated well with conservative management. There was no other significant complications noted. Patient's satisfactory score was assessed by the height, design and location of the nipple. The average of satisfaction score was 85%, 68%, 62% and total average was 83%. Conclusion: The authors experienced 17 patients of nipple reconstruction using the C - V flap technique after breast reconstruction with the only breast expander. The absorption rate of the size of the nipple, complications and patient's satisfactory score of this study were similar to those of nipple reconstruction after breast reconstruction with the autologous tissue. It is expected that nipple reconstruction after breast reconstruction with the only breast expander is safe and reliable. It is considered that a long - term study is necessary.

Comparative Analysis of Gait Parameters and Symmetry between Preferred Walking Speed and Walking Speed by using the Froude Number

  • Yoo, Si-Hyun;Kim, Jong-Bin;Ryu, Ji-Seon;Yoon, Suk-Hoon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.221-228
    • /
    • 2016
  • Objective: The purpose of this study was to investigate differences in gait parameters and symmetry between walking speed by using the Froude number and preferred walking speed. Method: Fifty adults (age: $21.0{\pm}1.7years$, body weight: $71.0{\pm}9.2kg$, height: $1.75{\pm}0.07m$, leg length: $0.89{\pm}0.05m$) participated in this study. Leg length-applied walking speed was calculated by using the Froude number, defined as Fr = ${\upsilon}^2$/gL, where v is the velocity, g is the gravitational acceleration, and L is the leg length. Video data were collected by using eight infrared cameras (Oqus 300, Qualysis, Sweden) and the Qualisys Track Manager software (Qualisys, Sweden), with a 200-Hz sampling frequency during two-speed walking (preferred walking speed [PS] and leg length-applied walking speed [LS]) on a treadmill (Instrumented Treadmill, Bertec, USA). The step length, stride length, support percentage, cadence, lower joint angle, range of motion (ROM), and symmetry index were then calculated by using the Matlab R2009a software. Results: Step and stride lengths were greater in LS than in PS (p < 0.05). The right single-support percentage was greater in LS than in PS (p < 0.05). The hip joint angle at heel contact and toe-off were greater in LS than in PS (p < 0.05). The hip and knee joint ROM were greater in LS than in PS (p < 0.05). Conclusion: Based on our findings, we suggest that increased walking speed had a significant effect on step length, stride length, support percentage, and lower joint ROM.

Kinematic Analysis of Samdan Didimsae Movement for Jajinmori Jangdan (자진모리장단에 따른 한국무용3단 디딤새 동작에 관한 운동학적 분석)

  • Ahn, Wan-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.203-212
    • /
    • 2008
  • The purpose of this study is to propose appropriate model for 3 staged Didimsae movement to Jajinmori rhythm and to provide information for ideal foot step movements. For the locational change of body center, the height of body center is lowered at the moment of forward step and during forward intersection of the feet, forward direction linear motion is converted to vertical motion to maintain stability. Speed change of body center reduces flow of body on step forward moment and controls rapid forward movement for stabled movement and position when preventing fast forward horizontal direction movement of centroid speed while knee joint and foot joint are vertically risen for heel bone contacts the ground. For angle changes of joints, in order to prevent hyperextension of lower leg, hip joint is extended and knee joint is curved to secure stability of movement for smooth curves and extension. When centroid of foot joint is moved from top of the feet to whole foot sole and when left foot makes dorsal curve, stabled movement is accomplished.

The Parallax Correction to Improve Cloud Location Error of Geostationary Meteorological Satellite Data (정지궤도 기상위성자료의 구름위치오류 개선을 위한 시차보정)

  • Lee, Won-Seok;Kim, Young-Seup;Kim, Do-Hyeong;Chung, Chu-Yong
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.99-105
    • /
    • 2011
  • This research presents the correction method to correct the location error of cloud caused by parallax error, and how the method can reduce the position error. The procedure has two steps: first step is to retrieve the corrected satellite zenith angle from the original satellite zenith angle. Second step is to adjust the location of the cloud with azimuth angle and the corrected satellite zenith angle retrieved from the first step. The position error due to parallax error can be as large as 60km in case of 70 degree of satellite zenith angle and 15 km of cloud height. The validation results by MODIS(Moderate-Resolution Imaging Spectrometer) show that the correction method in this study properly adjusts the original cloud position error and can increase the utilization of geostationary satellite data.

Preparation and Characterization of Mesophase Pitches from Petroleum Residues using Two-step Heat Treatment (석유계 잔사유로부터 저온 2단 열처리를 이용한 메조페이스 핏치 제조 및 특성)

  • JO, HANJOO;JUNG, MIN-JUNG;LEE, HYUNG-IK;LEE, YOUNG-SEAK
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.4
    • /
    • pp.421-430
    • /
    • 2016
  • To prepare mesophase pitches through low energy process, pyrolysis fuel oil with $AlCl_3$ has been modified using two-step heat treatment which is heat-treated at $330^{\circ}C$ for 3~5 h after pre-treatment at $250^{\circ}C$. The result of polarized optical microscope observation, mesophase is not observed in pitches carried out only pre-heat treatment. While mesophase content is significantly increased from 9% to 100% according to increasing secondary heat treatment time from 3 h to 5 h. Synthesizing of the mesophase pitch at low temperature of $330^{\circ}C$ is attributed to decrease of viscosity of the pitches carried out first heat treatment with $AlCl_3$. The result of Fourier-transform infrared spectroscopic analysis, it is expected that aromatization of aliphatic compounds is dominant at early secondary heat treatment, on the other hand, polycondensation reaction becomes dominant as secondary heat treatment time increases. Aromaticity and stacking height of the pitches secondary heat treated for 5 hours are more increased about 25% and 107%, respectively, than that of pitches carried out only first heat treatment.