• 제목/요약/키워드: Step cooling

검색결과 196건 처리시간 0.026초

Multiseeding 법으로 성장시킨 YBa$_2Cu_3O_x$ 고온초전도 단결정의 특성과 미세구조 (Magnetic properties and Microstructure of YBa$_2Cu_3O_x$ High Temperature Superconducting Single Crystals Grown by Multi-seeding)

  • 한영희;성태현;한상철;이준성;김상준
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.384-387
    • /
    • 1999
  • A new multi-seeding process for the growth of YBa$_2Cu_3O_x$ single crystals was developed. This process introduces an additional heating step to peritectic temperature and a subsequent slow cooling step to the growth temperature following the point when the crystals contacted. The crystal growth was resumed thereafter. The results obtained with this new process were compared with those of the conventional growth process, in which materials were only kept at the growth temperature. There was significant improvement in trapped magnetic field over the conventional multi-seeding process, which is believed to be due to complete elimination of liquid phase between crystals.

  • PDF

Monitor backcover의 사출시간 단축에 관한 연구 (A Study on The Reduction of Cycle Time in Injection Molding Process of The Monitor Backcover)

  • 김주권;김종선;윤경환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2004
  • The present study used a diagrammatic analysis of 6 sigma quality control and Taguchi method for injection molding process of monitor back-cover, evaluated the influence on the cycle time with part design, mold design, molding process and standardization activity involving design & molding, adopted analysis of sensitivity and effective factors of the part design and molding process conditions for productivity, identified main design molding factors, as critical ones influencing on the quality and productivity, of which is summarized as design guidance. The main contribution factors for cycle time can be sequentially enumerated as follows; hot spot, part thickness, coolant inlet temperature, melt temperature cooling line layout, etc.. As a first step critical factors of the design process of current monitor housing were investigated. And the optimal and better critical factors found in the first step were applied to a new product proving our process was correct. Moldflow software was used for injection molding simulation, and Minitab software for the statistical analysis. Finally, the productivity was increased by about 33 percents for our specific case.

  • PDF

내장형 모터와 리니어 모터를 적용한 초고속 수평형 머시닝센터의 열 특성 해석 (Thermal Characteristic Analysis of a High-Speed Horizontal Machining Center with Built-in Motor and Linear Motors)

  • 김석일;조재완
    • 한국공작기계학회논문집
    • /
    • 제13권5호
    • /
    • pp.30-37
    • /
    • 2004
  • This paper presents the thermal characteristic analysis of a high-speed horizontal machining center with spindle speed of 50,000rpm and feedrate of 120m/min. The spindle system is designed based on the built-in motor, angular contact ceramic ball bearings, oil-air lubrication and oil-jacket cooling method. The X-axis and Y-axis feeding systems are composed of the linear motors and linear motion guides, and the Z-axis feeding system is composed of the servo-motor, ball screw and linear motion guides. The thermal characteristics such as the temperature distribution, temperature rise, thermal deformation and step response, are estimated based on the finite element model of machining center and the heat generation rates of heat sources related to the machine operation conditions. Especially, the thermal time constant assessed from the step response function is introduced as an index of thermal response characteristics.

생쥐난자의 초급속동결 (Ultrarapid Freezing of Mouse Ova)

  • 박영식;서태광;이택후;전상식
    • 한국수정란이식학회지
    • /
    • 제10권3호
    • /
    • pp.203-208
    • /
    • 1995
  • This study was carried out to efficiently use the ultrarapid freezing method in the cryopreservation of mouse ova. For this, the effects of dehydration method, oval vigour and $0^{\circ}C$ controlling method on post-thawing viability were investigated. Fresh mouse ova were dehydrated in mPBS with 3.5M DMSO and /or 0.25M sucrose, and directly immersed in L$N_2$ for ultrarapidly freezing. The frozen ova were thawed at 37$^{\circ}C$, rehydrated in mPBS with 0.25M sucrose, and then repeatedly washed in HAM's Fl0 before evaluating the morphological normality of frozen-thawed ova. The results obtained showed that there was difference between treatments in a experiment. 1) The post-thawing viability of ova dehydrated in multi-step (48.4$\pm$13.8%) was higher than that of ova in two-step (40.9$\pm$14.0%). 2) The post-thawing viability of fertilized ova (87$\pm$14.0%) was significantly(p<0.0l) higher than that of unfertilized ova (5.4$\pm$5.4%). 3) The post-thawing viability of ova dehydrated and rehydrated using a cooling machine (95.8$\pm$4.2%) was significantly(p<0.05) higher than that on ice(84.1$\pm$9.9). In conclusion, in order to efficiently cryopreserve ova in vitro with ultrarapidly freezing method, highly viable embryos should be selected, heavy osmotic shock to the dehydrating ova should be avoided, and embryos in high osmotic condition were dehydrated and rehydrated in a constantly low temperature.

  • PDF

Simulation of Containment Pressurization in a Large Break-Loss of Coolant Accident Using Single-Cell and Multicell Models and CONTAIN Code

  • Noori-Kalkhoran, Omid;Shirani, Amir Saied;Ahangari, Rohollah
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1140-1153
    • /
    • 2016
  • Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA) by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model). In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP) containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code's results.

재난 시 대응을 위한 Flexible-Unit형 인프라 프리(임시)주거의 성능평가 (Evaluation of Residential Performance in Commercialization of Flexible Unit Infra Free Residential for Disaster)

  • 박병용;조진균;정용대;이원학
    • 한국태양에너지학회 논문집
    • /
    • 제38권6호
    • /
    • pp.37-49
    • /
    • 2018
  • In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The design trend implemented the energy insulation, solar PV panels, energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated the physical performance, insulation, airtightness. The second step, we was evaluated energy performance building to design heating and cooling system to combined PV system. As a results, the insulation performance wall was $0.18W/(m^2{\cdot}K)$. The results of air-tightness was 12.13 ACH@50 (1/h). The building energy demand ratings and solar energy generation has the possible to be ballanced.

An experimental and numerical analysis of concrete walls exposed to fire

  • Baghdadi, Mohamed;Dimia, Mohamed S.;Guenfoud, Mohamed;Bouchair, Abdelhamid
    • Structural Engineering and Mechanics
    • /
    • 제77권6호
    • /
    • pp.819-830
    • /
    • 2021
  • To evaluate the performance of concrete load bearing walls in a structure under horizontal loads after being exposed to real fire, two steps were followed. In the first step, an experimental study was performed on the thermo-mechanical properties of concrete after heating to temperatures of 200-1000℃ with the purpose of determining the residual mechanical properties after cooling. The temperature was increased in line with natural fire curve in an electric furnace. The peak temperature was maintained for a period of 1.5 hour and then allowed to cool gradually in air at room temperature. All specimens were made from calcareous aggregate to be used for determining the residual properties: compressive strength, static and dynamic elasticity modulus by means of UPV test, including the mass loss. The concrete residual compressive strength and elastic modulus values were compared with those calculated from Eurocode and other analytical models from other studies, and were found to be satisfactory. In the second step, experimental analysis results were then implemented into structural numerical analysis to predict the post-fire load-bearing capacity response of the walls under vertical and horizontal loads. The parameters considered in this analysis were the effective height, the thickness of the wall, various support conditions and the residual strength of concrete. The results indicate that fire damage does not significantly affect the lateral capacity and stiffness of reinforced walls for temperature fires up to 400℃.

AISI 9310강의 침탄열처리 경로가 조직 및 잔류응력 변화에 미치는 영향 (Effect of Carburizing Heat Treatment Process on Microstructure and Residual Stress Changes in AISI 9310 Steel.)

  • 정영철;배주현;박재만;오승준;성장현;노용식
    • 열처리공학회지
    • /
    • 제37권3호
    • /
    • pp.128-137
    • /
    • 2024
  • In this study, the carburizing heat treatment process used in aircraft gear manufacturing was compared with the general carburizing heat treatment process using AISI 9310 steel. The process of carburizing followed by slow cooling, and then quenching after austenitizing(Process A) showed less compressive residual stress and less retained austenite in the surface layer compared to the process of quenching directly after carburizing(Process B). In prpcess B, there was a large amount of retained austenite when quenched immediately after carburization, and when treated with subzero, martensite rapidly increased and the compressive residual stress increased significantly, but at the same time, there is a risk of cracking due to severe expansion in volume. Therefore, in the case of aviation parts, it is believed that a step-by-step heat treatment cycle was adopted to ensure stability against heat treatment cracks. As a result of the final tempering after sub-zero treatment, the A process specimen showed a deeper effective case depth and HV700 depth and a higher hardness value above HV700 than the B process specimen.

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 (Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront)

  • 조용;김대근;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

슬림 스피커 진동판의 분할진동 모드와 열전달 관계 분석을 통한 진동 패턴 예측 (Vibration Pattern Prediction through The Analysis on the Break-up Mode and the Heat Transfer Relationship of Slim Speaker Diaphragm)

  • 김현갑;김희식
    • 전자공학회논문지
    • /
    • 제53권10호
    • /
    • pp.109-115
    • /
    • 2016
  • 이 논문에서는 레이저를 통한 진동판 스캔과 열화상 카메라를 사용한 진동판 촬영, 두 가지 방법을 비교하며 슬림 스피커의 분할 진동을 검출하는 방법에 대해 살펴본다. 슬림 스피커는 평판형의 구조적인 특성상 분할진동이 두드러지게 나타나고, 설치되는 공간이 좁아 무빙 코일에서 발생하는 열의 냉각이 제한적이다. 이런 특성으로 인해 슬림 스피커에서 분할진동이 제품의 품질에 큰 영향을 미친다. 본 연구에서는 진동판에서 일어나는 분할진동의 영향과 무빙 코일에 의한 진동판의 열전달 관계를 비교 탐색한다. 비교를 위한 실험은 분할진동 모드의 측정과 진동판의 열 변화 측정을 진동판 스캔과 열화상 카메라 촬영의 2단계의 실험으로 진행한다. 동일 주파수에서 발생하는 분할진동 모드와 열전달 형태를 비교하여 서로 간에 어떤 영향을 미치고 있는 지 파악할 수 있다. 그리고 이를 통해 발견한 연관성을 통해 쉽게 촬영할 수 있는 열화상만으로도 슬림 스피커가 가지는 분할진동의 형태와 경향성을 빠르게 파악하여 최적 설계에 도움이 되는 자료로 사용할 수 있을 것이다.