• 제목/요약/키워드: Step Input Response

검색결과 149건 처리시간 0.03초

강인한 적분형 최적 모델 추종형 서보계의 구성에 관한 연구 (A design on robust integral-type optimal model following servo system)

  • 황창선;김정택;이양우;최일섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.1024-1027
    • /
    • 1992
  • This paper deals with design method of the model following servo system in which optimal regulator probelm is used to design the controllers that make the step/ramp response of the plant be keptclose to a specified ideal step/ramp response of the model. The characteristics of this system is robust in the presence of the specified disturbances or the partameter perturbations of the plant. Especially, by direct feedforward compensator from the reference input the steady state offset of plant output response is excluded and the transient response is improved. Examples are give and the results of the design of the model follwing servo systems are verified by the computer simulation.

  • PDF

고속응답, 저소비전력형 마이크로 유속센서의 제작과 그 특성 (The fabrication of high-response time, low consumption power, microflowsensor and its characteristics)

  • 홍석우;김병태;김길중;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.343-346
    • /
    • 2000
  • This paper presents the characteristics of low consumption, high-response time hot-film type micro-flowsensors with SOI(Si-on-insulator) and trench structures. Output voltages increased due to increase of heat-loss from sensor to external. Compared with no-trench on the SOI structure, the micro-flowsensors with trench structures have properties of high output voltage and low consume power. Output voltage of micro-flowsensors with SOI and trench structures was 250 mV at $N_2$ flow rate of 2000 sccm/min, heating power of 0.3 W. The response time was about 85 msec when input flow was step-input.

  • PDF

삼각함수형 RC분포회로의 과도응답해석 (Transient Response Analysis of the Trigonometric Distributed RC Circuit)

  • 김덕진
    • 대한전자공학회논문지
    • /
    • 제4권4호
    • /
    • pp.13-18
    • /
    • 1967
  • 삼각함수형 선형 수동 RC분포회로의 전압전달함수의 모든 극점은 s-평면상에서 부의 실축상에 존재하므로 unit step input에 대한 과도응답은 단조한 특성을 갖는다. 이러한 특성은 집중정수회로에 적용하였던 Elmore의 상승시간 및 지연시간 계산방법을 RC분포회로에도 적용시킬 수 있는 충분한 조건이므로 본 논문에서는 삼각함수형 RC분포회로의 과도응답특성해석을 위의 방법으로 시도하였다. 그 결과 이 회로의 상승시간 및 지연시간은 시정수 및 거리각 θ의 증가와 더불어 이들 시간도 증가함을 확인하였다.

  • PDF

능동진동제어를 이용한 유연보의 끝단위치 명령추종연구 (Tip Position Command Tracking of a Flexible Beam Using Active Vibration Control)

  • Lee, Young-Sup;Elliott, Stephen-J
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.643-648
    • /
    • 2003
  • The problem considered in this paper is that the tip position of a flexible cantilever beam is controlled to follow a command signal, using a pair of piezoelectric actuators at the clamped end. The beam is lightly damped and so the natural transient response is rather long, and also since the sensor and actuator are not collocated, the plant response is non-minimum phase. Two control strategies were investigated. The first involved conventional PID control in which the feedback gains were adjusted to give the fastest closed-loop response to a step input. The second control strategy was based on an internal model control (IMC) architecture. The control filter in the IMC controller was a digital FIR device designed to minimize the expectation of the mean square tracking error. The IMC controller designed fur the beam was found to have very much reduced settling times to a step input compared with those of the PID controller.

  • PDF

Dynamic Investigation of the Brushless DC Motor

  • Sirilappanich, Surachet;Somchaiwong, Nitipong;Pongswatd, Sawai;Ukakimapurn, Prapart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1867-1870
    • /
    • 2003
  • The analysis and simulation are the method to study the behavior, response, and specification of the driver device. This paper proposes brushless DC drive which using the vector control technique. The encoder is used detect the rotor position and decode to Three-phase step signal. The step signal is modulated with triangle signal and change to the pulse width modulation (PWM) signal. The PWM signal is used for control the input power of the motor based on the vector control technique. The experimental results of the driver circuit and motor response performed under the following condition: as the motor was started, change the load torque, and vary the supply voltage. The experimental performs with a dynamometer and the test results are compared to the simulation method is the same result.

  • PDF

STATCOM을 사용한 다기 전력 계통의 버스 전압 조절을 위한 모델 기반 PID 제어기 설계 (Innovative Model-Based PID Control Design for Bus Voltage Regulation with STATCOM in Multi-Machine Power Systems)

  • 김석균;이영일;송화창;김정수
    • 제어로봇시스템학회논문지
    • /
    • 제19권4호
    • /
    • pp.299-305
    • /
    • 2013
  • The complexity and severe nonlinearity of multi-machine power systems make it difficult to design a control input for voltage regulation using modern control theory. This paper presents a model-based PID control scheme for the regulation of the bus voltage to a desired value. To this end, a fourth-order linear system is constructed using input and output data obtained using the TSAT (Transient Security Assessment Tool); the input is assumed to be applied to the grid through the STATCOM (STATic synchronous COMpensator) and the output from the grid is a bus voltage. On the basis of the model, it is identified as to which open-loop poles of the system make the response to a step input oscillatory. To reduce this oscillatory response effectively, a model-based PID control is designed in such a way that the oscillatory poles are no longer problematic in the closed loop. Simulation results show that the proposed PID control dampens the response effectively.

Optimization of ground response analysis using wavelet-based transfer function technique

  • Moghaddam, Amir Bazrafshan;Bagheripour, Mohammad H.
    • Geomechanics and Engineering
    • /
    • 제7권2호
    • /
    • pp.149-164
    • /
    • 2014
  • One of the most advanced classes of techniques for ground response analysis is based on the use of Transfer Functions. They represent the ratio of Fourier spectrum of amplitude motion at the free surface to the corresponding spectrum of the bedrock motion and they are applied in frequency domain usually by FFT method. However, Fourier spectrum only shows the dominant frequency in each time step and is unable to represent all frequency contents in every time step and this drawback leads to inaccurate results. In this research, this process is optimized by decomposing the input motion into different frequency sub-bands using Wavelet Multi-level Decomposition. Each component is then processed with transfer Function relating to the corresponding component frequency. Taking inverse FFT from all components, the ground motion can be recovered by summing up the results. The nonlinear behavior is approximated using an iterative procedure with nonlinear soil properties. The results of this procedure show better accuracy with respect to field observations than does the Conventional method. The proposed method can also be applied to other engineering disciplines with similar procedure.

트랙터의 수평제어를 위한 유압 시스템의 특성 실험 (Implementation and Test of Hydraulic Control System for the Tractor Leveling)

  • 이상식;오기석;황헌
    • Journal of Biosystems Engineering
    • /
    • 제24권5호
    • /
    • pp.383-390
    • /
    • 1999
  • When a tractor travels slope lands, problems of operator safety and the reduction of job efficiency usually occur. Therefore, maintaining the tractor body being horizontal is critical to improve the security of traveling and the job performance. An experiment was made in a soil bin using the experimental model system built and equipped with a leveling control system. Adaptability of the control system was tested and investigated by analyzing system response in time and frequency domains. Control response time of hydraulic cylinder with 10lpm flow rate on a step input of 10$^{\circ}$slope was about 0.42sec. And it showed a linearly increasing trend without any hunching state. A steady state error of 0.6$^{\circ}$occurred but it was negligible. The hydraulic control system showed a little phase differences within the range of 0.4Hz input frequency. The experimental model showed that implementation of the proposed tractor control system to on slope lands tractor was feasible.

  • PDF

단상 AC/AC 컨버터에 관한 연구 (A study on the single phase AC/AC converter)

  • 배상준;정타관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1931-1933
    • /
    • 1998
  • In this paper, single-phase PWM AC to AC converter that operates with unit power factor and sinusoidal input line currents is presented. The output voltage of this converter is able to be obtain step up voltage as well as step down voltage. because the converter applies to operating method of buck-boost converter. The control of this converter is performed with PI control method. By using this control method low lipples in the output current and the voltage as well as fast dynamic response are achieved.

  • PDF

용량성 전장센서를 이용한 과도전압측정계 (Transient Voltage Measuring System Using the Capacitive Electric Field Sensor)

  • 이복희;길경석;주문노;이성헌
    • 센서학회지
    • /
    • 제5권3호
    • /
    • pp.9-16
    • /
    • 1996
  • 본 논문에서는 고전압 임펄스전압 발생장치의 조작에 의하여 발생하는 과도전압을 측정할 수 있는 용량성분 압기를 실현하였다. 전장센서를 이용한 과도전압측정계는 고속응답의 평판형 전장센서와 광대역 전압버퍼로 구성되었으며, 사용된 전압버퍼(LH0033)의 입력임피던스는 $10^{12}{\Omega}$ 정도로 대단히 높다. 단위계단 응답특성을 파악하기 위하여 새로운 교정방법을 제안하고, 설치조건에 따른 분압비 오차를 검토하였으며, 분압비 오차를 0.5% 이내로 하기 위한 최적설치조건을 제시하였다. 교정실험으로부터 과도전압측정계의 응답시간은 약 15.78 ns이었으며, 주파수대역은 6.37 Hz에서 27.3MHz이다. 따라서 본 측정계로 과도과전압은 물론 상용주파수전압도 신호의 일그러짐 없이 측정이 가능하였다.

  • PDF