• Title/Summary/Keyword: Step Heating

Search Result 237, Processing Time 0.032 seconds

Effects of Substrate Cleaning on the Properties of GaAs Epilayers Grown on Si(100) Substrate by Molecular Beam Epitaxy (분자선에피택시에 의해 Si (100) 기판 위에 성장한 GaAs 에피층의 특성에 대한 기판 세척효과)

  • Cho, Min-Young;Kim, Min-Su;Leem, Jae-Young
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.371-376
    • /
    • 2010
  • The GaAs epitaxial layers were grown on Si(100) substrates by molecular beam epitaxy (MBE) using the two-step method. The Si(100) substrates were cleaned with three different surface cleaning methods of vacuum heating, As-beam exposure, and Ga-beam deposition at the substrate temperature of $800^{\circ}C$ in the MBE growth chamber. Growth temperature and thickness of the GaAs epitaxial layer were $800^{\circ}C$ and $1{\mu}m$, respectively. The surface structure and properties were investigated by reflection high-energy electron diffraction (RHEED), AFM (Atomic force microscope), DXRD (Double crystal x-ray diffraction), PL (Photoluminescence), and PR (Photoreflectance). From RHEED, the surface structure of GaAs epitaxial layer grown on Si(100) substrate with Ga-beam deposition is ($2{\times}4$). The GaAs epitaxial layer grown on Si(100) substrate with Ga-beam deposition has a high quality.

A Study on the Effect of Gamma Background in Low Power Startup Physics Tests (저출력 노물리 시험에서의 감마 Background의 영향에 관한 연구)

  • Bae, Chang-Joon;Lee, Ki-Bog
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.361-370
    • /
    • 1993
  • Low power physics tests should be peformed for the domestic pressurized light water reactors (PWRs) after refueling. The tests are peformed to ensure that operating characteristics of the core are consistent with predictions and that the core can be operated as designed. But in some low power physics tests, slow but steady reactivity increasing phenomena were noticed after step reactivity insertion by the control rod movement. These reactivity increasing phenomena are due to the low flux level and the gamma background because an uncompensated ion chamber (UIC) is used as the ex-core neutron detector. The gamma background may affect the results or the lour power physics tests. The aims or this paper are to analyze the grounds of such phenomena, to simulate a reference bank worth measurement test and to present a resolution quantitatively. In this study, the gamma background level was estimated by numerically solving the point kinetics equations accounting the gamma background effect. The reactivity computer check test was simulated to verify the model. Also, an appropriate neutron flux level was determined by simulating the reference bank worth measurement test. The determined neutron flux level is approximately 0.3 of the nuclear heating flux. This level is about 3 times as high as the current test upper limit specified in the test procedure. Then, the findings from this work were successfully applied to Kori unit 4 cycle 7 and Yonggwang unit 1 cycle 7 physics tests.

  • PDF

Variation of Hydrogen Residue on Metallic Samples by Thermal Soaking in an Inert Gas Environment (불활성 가스하 열건조에 따른 금속시험편의 수소잔류물 거동 분석)

  • Lee, Yunhee;Park, Jongseo;Baek, Unbong;Nahm, Seunghoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 2013
  • Hydrogen penetration into a metal leads to damages and mechanical degradations and its content measurement is of importance. For a precise measurement, a sample preparation procedure must be optimized through a series of studies on sample washing and drying. In this study, two-step washing with organic solvents and thermal soaking in inert gas were tried with a rod-shaped, API X65 steel sample. The samples were machined from a steel plate and then washed in acetone and etyl-alcohol for 5 minute each and dried with compressed air. After then, the samples were thermally soaked in a home-made nitrogen gas chamber during 10 minute at different heat gun temperatures from 100 to $400^{\circ}C$ and corresponding temperature range in the soaking chamber was from 77 to $266^{\circ}C$ according to the temperature calibration. Hydrogen residue in the samples was measured with a hot extraction system after each soaking step; hydrogen residue of $0.70{\pm}0.12$ wppm after the thermal soaking at $77^{\circ}C$ decayed with increase of the soaking temperature. By adopting the heat transfer model, decay behavior of the hydrogen residue was fitted into an exponential decay function of the soaking temperature. Saturated value or lower bound of the hydrogen residue was 0.36 wppm and chamber temperature required to lower the hydrogen residue about 95% of the lower bound was $360^{\circ}C$. Furthermore, a thermal desorption spectroscopy was done for the fully soaked samples at $360^{\circ}C$. Weak hydrogen peak was observed for whole temperature range and it means that hydrogen-related contaminants of the sample surface are steadily removed by heating. In addition, a broad peak found around $400^{\circ}C$ means that parts of the hydrogen residue are irreversibly trapped in the steel microstructure.

Titanium Isopropoxide (TTIP) Treatment Strategy for V2O5-WO3/TiO2 SCR Catalysts with a Wide Operating Temperature (넓은 작동 온도범위를 가지는 V2O5-WO3/TiO2 SCR 촉매 개발을 위한 티타늄 이소프로폭사이드(TTIP) 활용 전략)

  • Jaeho Lee;Gwang-hun Cho;Geumyeon Lee;Changyong Yim;Young-Sei Lee;Taewook Kim
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.357-364
    • /
    • 2023
  • Selective catalytic reduction (SCR) is the most effective method for reducing nitrogen oxide emissions, but the operating temperature range of V2O5-WO3/TiO2 catalysts is narrow (300~400℃). In this study, a new catalyst with an operating temperature range of 200~450℃ was developed. The catalyst poison, ammonium bisulfate, generated during the SCR process can be removed by heating above 350℃. To increase the number of active sites and promote the dispersion of active materials, titanium isopropoxide (TTIP) treatment was performed on the TiO2 support with various TTIP/TiO2 mass ratios. Among them, the 5 wt% TTIP loaded catalyst showed improved performance due to higher thermal stability caused by high W dispersion and the formation of V5+. In addition, the 5 wt% TTIP-loaded catalyst prepared by a one-step co-precipitation method showed greater V-OH and W-OH dispersion and enhanced interactions in contrast to conventional methods, resulting in higher catalytic activity at lower temperatures. This review article aims to provide an accessible explanation for researchers investigating how to improve the surface properties of TiO2 catalysts using TTIP.

2D Fluid Modeling of Ar Plasma in a 450 mm CCP Reactor

  • Yang, Won-Gyun;Kim, Dae-Ung;Yu, Sin-Jae;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.267-267
    • /
    • 2012
  • 최근 국내 반도체 장비 업체들에 의해서 차세대 반도체용 450 mm 웨이퍼 공정용 장비 개발이 진행 중에 있다. 반도체 산업은 계속해서 반도체 칩의 크기를 작게 하고, 웨이퍼 크기를 늘리면서 웨이퍼 당 칩수를 증가시켜 생산성을 향상해오고 있다. 현재 300 mm 웨이퍼에서 450 mm 웨이퍼를 도입하게 되면, 생산성 뿐만 아니라 30%의 비용절감과 50%의 cycle-time 단축이 기대되고 있다. 장비에 대한 이해와 공정에 대한 해석 능력을 위해 비용과 시간이 많이 들기 때문에 최근 컴퓨터를 활용한 수치 모델링이 진행되고 있다. 또한, 수치 모델링은 실험 결과와의 비교가 필수적이다. 본 연구에서는 450 mm 웨이퍼 공정용 장비의 전자밀도를 cut off probe를 통해 100 mTorr에 서 Ar 플라즈마를 파워에 따라 측정했다. 13.56 MHz 200 W, 500 W, 1,000 W로 입력 파워가 증가하면서 웨이퍼 중심에서 $6.0{\times}10^9#/cm^3$, $1.35{\times}10^{10}#/cm^3$, $2.4{\times}10^{10}#/cm^3$로 증가했다. 450 mm 웨이퍼 영역에서 전자 밀도의 불균일도는 각각 10.31%, 3.24%, 4.81% 였다. 또한, 이 450 mm 웨이퍼용 CCP 장비를 축대칭 2차원으로 형상화하고, 전극에 13.56 MHz를 직렬로 연결된 blocking capacitor ($1{\times}10^{-6}$ F/$m^2$)를 통해 인가할 수 있도록 상용 유체 모델 소프트웨어(CFD-ACE+, EXI corp)를 이용하여 계산하였다. 주요 전자-중성 충돌 반응으로 momentum transfer, ionization, excitation, two-step ionization을 고려했고, $Ar^+$$Ar^*$의 표면 재결합 반응은 sticking coefficient를 1로 가정했다. CFD-ACE+의 CCP 모델을 통해 Poisson 방정식을 풀어서 sheath와 wave effect를 고려하였다. Stochastic heating을 고려하지 않았을 때, 플라즈마 흡수 파워가 80 W, 160 W, 240 W에서 실험 투입 전력 200 W, 500 W, 1,000 W일 때와 유사한 반경 방향의 플라즈마 밀도 분포를 보였다. 200 W, 500 W, 1,000 W일 때의 전자밀도 분포는 수치 모델링과 전 범위에서 각각 10%, 3%, 2%의 오차를 보였다. 450 mm의 전극에 13.56 MHz의 전력을 인가할 때, 파워가 증가할수록 전자밀도의 최대값의 위치가 웨이퍼 edge에서 중심으로 이동하고 있음을 실험과 모델링을 통해 확인할 수 있었다.

  • PDF

Effects of Induction Heat Bending Process on Microstructure and Corrosion Properties of ASME SA312 Gr.TP304 Stainless Steel Pipes

  • Kim, Nam In;Kim, Young Sik;Kim, Kyung Soo;Chang, Hyun Young;Park, Heung Bae;Sung, Gi Ho
    • Corrosion Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.120-126
    • /
    • 2015
  • The usage of bending products recently have increased since many industries such as automobile, aerospace, shipbuilding, and chemical plants need the application of pipings. Bending process is one of the inevitable steps to fabricate the facilities. Induction heat bending is composed of compressive bending process by local heating and cooling. This work focused on the effect of induction heat bending process on the properties of ASME SA312 Gr. TP304 stainless steel pipes. Tests were performed for base metal and bended area including extrados, intrados, crown up, and down parts. Microstructure was analyzed using an optical microscope and SEM. In order to determine intergranular corrosion resistance, Double Loop Electrochemical Potentiokinetic Reactivation (DL-EPR) test and ASTM A262 practice A and C tests were done. Every specimen revealed non-metallic inclusion free under the criteria of 1.5i of the standard and the induction heat bending process did not affect the non-metallic inclusion in the alloys. Also, all the bended specimens had finer grain size than ASTM grain size number 5 corresponding to the grain sizes of the base metal and thus the grain size of the pipe bended by induction heat bending process is acceptable. Hardness of transition start, bend, and transition end areas of ASME SA312 TP304 stainless steel was a little higher than that of base metal. Intergranular corrosion behavior was determined by ASTM A262 practice A and C and DL-EPR test, and respectively step structure, corrosion rate under 0.3 mm/y, and Degree of Sensitization (DOS) of 0.001~0.075% were obtained. That is, the induction heat bending process didn't affect the intergranular corrosion behavior of ASME SA312 TP304 stainless steel.

Recurrent Neural Network Models for Prediction of the inside Temperature and Humidity in Greenhouse

  • Jung, Dae-Hyun;Kim, Hak-Jin;Park, Soo Hyun;Kim, Joon Yong
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.135-135
    • /
    • 2017
  • Greenhouse have been developed to provide the plants with good environmental conditions for cultivation crop, two major factors of which are the inside air temperature and humidity. The inside temperature are influenced by the heating systems, ventilators and for systems among others, which in turn are geverned by some type of controller. Likewise, humidity environment is the result of complex mass exchanges between the inside air and the several elements of the greenhouse and the outside boundaries. Most of the existing models are based on the energy balance method and heat balance equation for modelling the heat and mass fluxes and generating dynamic elements. However, greenhouse are classified as complex system, and need to make a sophisticated modeling. Furthermore, there is a difficulty in using classical control methods for complex process system due to the process are non linear and multi-output(MIMO) systems. In order to predict the time evolution of conditions in certain greenhouse as a function, we present here to use of recurrent neural networks(RNN) which has been used to implement the direct dynamics of the inside temperature and inside humidity of greenhouse. For the training, we used algorithm of a backpropagation Through Time (BPTT). Because the environmental parameters are shared by all time steps in the network, the gradient at each output depends not only on the calculations of the current time step, but also the previous time steps. The training data was emulated to 13 input variables during March 1 to 7, and the model was tested with database file of March 8. The RMSE of results of the temperature modeling was $0.976^{\circ}C$, and the RMSE of humidity simulation was 4.11%, which will be given to prove the performance of RNN in prediction of the greenhouse environment.

  • PDF

Design Checklist for Self-sufficient Zero Energy Solar House(ZeSH) (에너지자립형 태양열 주택의 설계 및 시공 방법 체크리스트 수립 연구)

  • Yoon Jongho;Baek Namchoon;Yu Changkyun;Kim Jongil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.416-421
    • /
    • 2005
  • Most of solar system dissemination has been focused on domestic hot water system of which utilization to a building is relatively simple and safe than solar heating system. Through the survey on a cause of solar house dissemination failure in Korea, we conclude that design integration and systematic approach method for technology application are the most important element for a successful solar house. KIER(Korea Institute of Energy Research) and Hanbat National University have started new project on a development of Zero energy Solar House, called ZeSH which can be sustained just by natural energy without the support of existing fossil fuel. This is the 1st phase research of 10 years long-term ZeSH plan which develops a low-cost and $100\%$ self sufficient ZeSH. The goal of 1st phase ZeSH research is to get a $70\%$ self sufficiency only in thermal loads. Actual demonstration house, named KIER ZeSH I was designed and constructed as a result of 1st phase research work in the end of 2002. Various innovative technologies such as super insulation, high performance window, passive and active solar systems, ventilation heat recovery system are applied and evaluated to the KIER ZeSH I. A lot of computer simulations had been conducted for the optimal design and system integration in every design steps. Considering all the results from detailed hourly computer simulation, it is expected that at least $70\%$ self-sufficiency in thermal loads which is 1st phase target value can be excessively achieved in actual demonstration house. Besides, many valuable findings from the design and analysis to construction could be established such as collaboration method among the participants, practical design and construction techniques for system integration and the others. The purpose of this paper is to introduce the main findings through the development of KIER ZeSH I project. Practical guidelines in every design step for new low- or zero- energy solar house is proposed as result.

  • PDF

Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD (중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석)

  • Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.141-149
    • /
    • 2009
  • In this paper, quasi-static FDTD method is implemented by FORTRAN programming, and it is used for analysis of body induced current in middle frequencies. The quasi-static FDTD program is validated by comparing the calculation result with analytic solution of the test model, to which it is difficult to apply conventional FDTD. It is confirmed that the time-step is reduced by $5.68{\times}10^6$ times. Using validated numerical technique, body induced current distribution in high resolution 3-D human model is calculated for 20[kHz] magnetic field exposure and 1[MHz] electric field exposure. Also, the effect of grounding condition of both feet on the distribution and amplitude of the induced current is analyzed. It is expected that this research can be applied to various fields including safety assessment of body induced current and development of diagnosis devices using bio-electricity.

Cloning and Expression of the Gene for Inorganic Pyrophosphatase of Thermus caldophilus GK24 and Properties of the Enzyme

  • Hoe, Hyang-Sook;Jo, In-Geun;Shin, Hea-Jin;Jeon, Hyo-Jeong;Kim, Hyun-Kyu;Lee, Jin-Sung;Kim, Yong-Sung;Lee, Dae-Sil;Kwon, Suk-Tae
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.2
    • /
    • pp.301-305
    • /
    • 2002
  • The gene (ppaT) encoding Thermus caldophilus GK24 pyrophosphatase (Tca pyrophosphatase) was cloned and sequenced. The gene was found to contain an open reading frame encoding 175 amino acids with a calculated mass of 19,155 Da. The ppaT gene was expressed under the control of the tac promoter in Escherichia coli. The recombinant Tca pyrophosphatase was purified 21.4-fold with $56\%$ yield and specific activity of 25.7 U $mg^-1$, following a combination of heating (to denature the E. coli proteins) and one step of DEAE-Sephacel column chromatography. The native enzyme was found to have an approximate molecular mass of 110,000 Da and consisted of six subunits. The enzyme exhibited maximal activity at pH of 8.0-8.5 and was stable at $80-90^{\circ}C$. A divalent cation was absolutely required for the enzyme activity, with $Mg^2+$. being the most effective.