• 제목/요약/키워드: Stent occlusion

검색결과 92건 처리시간 0.027초

Endovascular Stroke Therapy Focused on Stent Retriever Thrombectomy and Direct Clot Aspiration : Historical Review and Modern Application

  • Kang, Dong-Hun;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권3호
    • /
    • pp.335-347
    • /
    • 2017
  • Intravenous recombinant tissue plasminogen activator had been the only approved treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time window, numerous contraindications, and its low recanalization rate were all limitations of this modality. Under those circumstances, endovascular stroke therapy went through a great evolution during the past two decades of intravenous thrombolysis. The results of the 2013 randomized trials for endovascular stroke therapy were neutral, although they were limited by insufficient imaging screening at enrollment, early-generation devices with less efficacy, and treatment delays. Huge progress was made in 2015, as there were five randomized clinical trials which all demonstrated the safety and efficacy of endovascular stroke treatment. Despite differences in detail patient enrollment criteria, all 5 trials employed key factors for good functional recovery; (1) screening with non-invasive imaging to identify the proximal occlusion and exclude a large infarct core, (2) using highly effective modern thrombectomy devices mainly with stent retriever, and (3) establishment of a fast workflow to achieve effective reperfusion. The results of those trials indicate that modern thrombectomy devices can allow for faster and more effective reperfusion, which can lead to improved clinical outcomes compared to intravenous thrombolysis alone. These advances in mechanical thrombectomy are promising in the global fight against ischemic stroke-related disability and mortality. Two current mainstreams among such mechanical thrombectomy techniques, "stent retriever thrombectomy" and "direct clot aspiration", are the topic of this review. Stent retriever thrombectomy using Solitaire and Trevo retriever will be firstly discussed. And, the commonalities and the differences between two major clot aspiration thrombectomy techniques; a direct aspiration first pass technique (ADAPT) and forced arterial suction thrombectomy (FAST), will be additionally explained. Finally, details regarding the combination of direct clot aspiration and stent retriever thrombectomy, the switching strategy and the Solumbra technique, will be described.

Evaluation of Stent Apposition in the LVIS Blue Stent-Assisted Coiling of Distal Internal Carotid Artery Aneurysms : Correlation with Clinical and Angiographic Outcomes

  • Kwon, Min-Yong;Ko, Young San;Kwon, Sae Min;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.801-815
    • /
    • 2022
  • Objective : To evaluate the stent apposition of a low-profile visualized intraluminal support (LVIS) device in distal internal carotid artery (ICA) aneurysms, examine its correlation with clinical and angiographic outcomes, and determine the predictive factors of ischemic adverse events (IAEs) related to stent-assisted coiling. Methods : We retrospectively analyzed a prospectively maintained database of 183 patients between January 2017 and February 2020. The carotid siphon from the cavernous ICA to the ICA terminus was divided into posterior, anterior, and superior bends. The anterior bends were categorized into angled (V) and non-angled (C, U, and S) types depending on the morphology and measured angles. Complete stent apposition (CSA) and incomplete stent apposition (ISA) were evaluated using unsubtracted angiography and flat-panel detector computed tomography. Dual antiplatelet therapy with aspirin 200 mg and clopidogrel 75 mg was administered. Clopidogrel resistance was defined as fewer responders (≥10%, <40%) and non-responders (<10%) based on the percent inhibition (%INH) of the VerifyNow system. These were counteracted by a dose escalation to 150 mg for fewer responders or substitution with cilostazol 200 mg for non-responders. IAEs included intraoperative in-stent thrombosis, transient ischemic attack, cerebral infarction, and delayed in-stent stenosis. A multivariate logistic regression analysis was used to determine the predictive factors for ISA and IAEs. Results : There were 33 ISAs (18.0%) and 27 IAEs (14.8%). The anterior bend angle was narrower in ISA (-4.16°±25.18°) than in CSA (23.52°±23.13°) (p<0.001). The V- and S-types were independently correlated with the ISA (p<0.001). However, treatment outcomes, including IAEs (15.3% vs. 12.1%), aneurysmal complete occlusion (91.3% vs. 88.6%), and recanalization (none of them), did not differ between CSA and ISA (p>0.05). The %INH of 27 IAEs (13.78%±14.78%) was significantly lower than that of 156 non-IAEs (26.82%±20.23%) (p<0.001). Non-responders to clopidogrel were the only significant predictive factor for IAEs (p=0.001). Conclusion : The angled and tortuous anatomical peculiarity of the carotid siphon caused ISA of the LVIS device; however, it did not affect clinical and angiographic outcomes, while the non-responders to clopidogrel affected the IAEs related to stent-assisted coiling.

Effectiveness and Safety of Mechanical Thrombectomy with Stent Retrievers in Basilar Artery Occlusion : Comparison with Anterior Circulation Occlusions

  • Hu, Soo Young;Yi, Ho Jun;Lee, Dong Hoon;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권6호
    • /
    • pp.635-643
    • /
    • 2017
  • Objective : Acute basilar artery occlusion (BAO) is associated with severe neurological dysfunction and high mortality rates. The benefits of mechanical thrombectomy in BAO have not been explored in recent clinical trials. Therefore, we analyzed outcomes of stent retriever mechanical thrombectomy for BAO, and compared with anterior circulation occlusions (ACO). Methods : In total, 161 consecutive patients (24 BAO, 137 ACO) who underwent mechanical thrombectomy with the stent retriever between January 2013 and August 2016 enrolled in our study. All patients underwent clinical assessment with the National Institutes of Health Stroke Scale (NIHSS) and modified Rankin scale (mRS). Radiological results were used to evaluate thrombolysis in cerebral infarction (TICI) scores and successful recanalization was defined by TICI 2b or 3. Results : Mean NIHSS scores at 24 hours and 30 days were significantly higher in the BAO group than the ACO group (p=0.021, p=0.001). mRS at 90 days was significantly higher in the BAO group (4.2) compared with the ACO group (3.0) (p=0.003). The BAO group (2.0) performed fewer stent retriever passages than the ACO group (2.7) (p=0.049). There were no significant differences between the two groups in terms of complications, but the BAO patients experienced a higher mortality (16.6%) rate than ACO patients (5.8%) (p=0.001). In subgroup analysis of BAO, patients with short procedure times achieved successful recanalization (p=0.001) and successfully recanalized patients exhibited more favorable mRS at 90 days (p=0.027). Conclusion : In our study, mechanical thrombectomy of BAO patients showed worse clinical outcome and higher mortality rate than ACO patients. However, mechanical thrombectomy with a stent retriever in BAO is an effective treatment, because successfully recanalized patients showed good clinical outcome in BAO patients.

Serial Vascular Responses of Balloon-Expandable Stent With Biodegradable Film-Type Graft in a Rabbit Iliac Artery Dissection Model (BioGard Study)

  • Sang Min Park;Kyung-Chan Choi;Byeong Han Lee;Sang Yol Yoo;Christopher Y. Kim
    • Korean Circulation Journal
    • /
    • 제54권8호
    • /
    • pp.499-512
    • /
    • 2024
  • Background and Objectives: Arterial dissection during endovascular therapy rarely occurs but can be lethal. A fabric-based covered graft stents yield poor clinical outcomes. A novel balloon-expandable stent with biodegradable film graft for overcoming these issues was evaluated in a rabbit iliac artery model. Method: Eighteen rabbits with iliac artery dissections were induced by balloon over-inflation on angiography (Ellis type 2 or 3) and treated using the test device (3.0×24 mm). Subsequently, survived twelve animals underwent histologic examinations and micro-computed tomography (CT) at 0, 2, 4, and 8 weeks and 3, 6, 9, and 12 months and angiography at one-year. Results: There were no adverse cardiovascular events during the one-year. Early-stage histologic examination revealed complete sealing of disrupted vessels by the device, exhibiting mural hematoma, peri-stent red thrombi, and dense infiltration of inflammatory cells. Mid- and long-term histologic examination showed patent stents with neointimal hyperplasia over the stents (% area stenosis: 11.8 at 2 weeks, 26.1 at 1 month, 29.7 at 3 months, 49.2 at 9 months, and 51.0 at 1 year), along with mild peri-strut inflammatory response (Grade: 1-2 at mid-term and 0-1 at long-term). The graft film became scarcely visible after six months. Both CT and angiography revealed no instances of thrombotic occlusion or in-stent restenosis (% diameter stenosis: 5.7 at 2 weeks, 12.3 at 1 month, 14.2 at 3 months, 25.1 at 9 months, and 26.6 at 1 year). Conclusions: The novel balloon-expandable stent with a biodegradable film graft demonstrates feasibility in managing severe artery dissection and preventing lethal vascular events in animal model.

선천성 심질환에 대한 중재적 치료술의 최근 진전 (Recent advances in transcatheter treatment of congenital heart disease)

  • 최재영
    • Clinical and Experimental Pediatrics
    • /
    • 제49권9호
    • /
    • pp.917-929
    • /
    • 2006
  • Over the last several decades there has been a remarkable change in the therapeutic strategy of congenital heart disease. Development of new tools and devices, accumulations of experience, technical refinement have positively affected the outcome of interventional treatment. Many procedures including atrial septostomy, balloon valvuloplasty, balloon dilation of stenotic vessel with or without stent implantation, transcatheter occlusion of abnormal vascular structure, transcatheter closure of patent arterial duct and atrial septal defect, are now performed as routine interventional procedures in many institutes. In diverse conditions, transcatheter techniques also provide complementary and additive role in combination with surgery. Intraoperative stent implantation on stenotic vessels, perventricular device insertion, and hybrid stage 1 palliative procedure for hypoplastic left heart syndrome have been employed in high risk patients for cardiac surgery with encouraging results. Transcatheter closure of ventricular septal defect has been performed safely showing comparable result with surgery. Investigational procedures such as percutaneous valve insertion and valve repair are expected to replace the role of surgery in certain group of patients in the near future. Continuous evolvement in this field will contribute to reduce the risk and suffering from congenital heart disease, while surgery will be still remained as a gold standard for significant portion of congenital heart disease.

Emergent Recanalization with Stenting for Acute Stroke due to Athero-Thrombotic Occlusion of the Cervical Internal Carotid Artery : A Single Center Experience

  • Choi, Jae Young;Lee, Jae Il;Lee, Tae Hong;Sung, Sang Min;Cho, Han Jin;Ko, Jun Kyeung
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권6호
    • /
    • pp.313-320
    • /
    • 2014
  • Objective : The purpose of this study is to demonstrate the technical feasibility and clinical efficacy of emergent carotid angioplasty and stenting (CAS) for acute stroke due to athero-thrombotic occlusion of the cervical internal carotid artery (ICA). Methods : Review of medical records identified 17 patients who underwent emergent CAS for treatment of athero-thrombotic occlusion of the cervical ICA with acute stroke between 2009 and 2013. Eleven patients (64.7%) presented with concomitant intracranial artery occlusion, which was treated primarily by mechanical thrombectomy after CAS. Results : Successful revascularization of the cervical ICA with emergent CAS was achieved in all patients. After CAS, intracranial recanalization with Thrombolysis in Cerebral Infarction ${\geq}2b$ flow was achieved in four of the 11 patients (36.4%). The overall recanalization rate (cervical ICA and intracranial artery) was 10 of 17 patients (58.8%). Symptomatic intracranial hemorrhage occurred in two patients (11.8%), resulting in death. Ten patients (58.8%) showed improvement (decrease in NIHSS score of ${\geq}4$ points) at seven days after recanalization. Nine patients (52.9%) showed a favorable outcome ($mRS{\leq}2$) at the last follow-up. A favorable outcome ($mRS{\leq}2$) was obtained in four of the six patients with isolated cervical ICA occlusion (4/6, 66.7%) and five of 11 patients with intracranial tandem occlusion (5/11, 45.5%). Conclusion : Emergent CAS for acute stroke due to athero-thrombotic occusion of the cervical ICA showed a good technical feasibility and favorable clinical outcome.

Is Stent-Assisted Coil Embolization for the Treatment of Ruptured Blood Blister-Like Aneurysms of the Supraclinoid Internal Carotid Artery Effective? : An Analysis of Single Institutional Experience with Pooled Data

  • Roh, Haewon;Kim, Junwon;Suh, Sang-il;Kwon, Taek-Hyun;Yoon, Wonki
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권2호
    • /
    • pp.217-228
    • /
    • 2021
  • Objective : Given the high risk of rebleeding and recurrence of blood blister-like aneurysms (BBAs), we treated ruptured BBAs of the internal carotid artery (ICA) with stent-assisted coil embolization (SAC). This study aimed to evaluate the efficacy and safety of SACs. Methods : We retrospectively reviewed clinical and radiological data from eight patients with ruptured BBAs of the supraclinoid ICA. The modified Rankin Scale (mRS) was used to assess clinical outcomes, while radiological outcomes were evaluated on angiographs. For a pooled analysis, data from literature reporting the outcomes of ruptured BBAs treated with SAC were collected and analyzed in conjunction with our data. Results : In our cohort, the mean Raymond classification score was 1.57±0.53 immediately after initial endovascular treatment. There were no perioperative complications or rebleeding events during the follow-up period. The mean mRS score at patient discharge was 1.00±0.81 and improved to 0.28±0.48 by the last follow-up day. The recurrence rate was 25% with an asymptomatic presentation and successful treatment with multiple stent insertion. Pooled analysis of 76 cases of SAC revealed a complete occlusion rate immediately after treatment of 54.8%, rebleeding rate 7.94%, and recurrence rate 24.2%. Good clinical outcomes with mRS score 0-2 were observed in 89.9% by the last clinical follow-up. Total mortality rate was 7.7%. Conclusion : This treatment appears to not only minimize the hemodynamic burden on the fragile dome specific to this type of aneurysm, but also provides an opportunity for safe and effective treatment in recurrent cases.

Stent-Assisted Coil Trapping in a Manual Internal Carotid Artery Compression Test for the Treatment of a Fusiform Dissecting Aneurysm

  • Seung, Won-Bae;Kim, Jin-Wook;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권5호
    • /
    • pp.296-300
    • /
    • 2012
  • Internal carotid artery (ICA) trapping can be used for the treatment of giant intracranial aneurysms, blood blister-like aneurysms, and fusiform dissecting aneurysms. Fusiform dissecting aneurysms are challenging to treat surgically and endovascularly because of no definite neck and critical perforators. Surgical or endovascular trapping of the ICA with or without an extracranial-intracranial bypass has commonly been used as an effective method to treat these lesions, but balloon test occlusion (BTO) must be performed. Here, we report a case of a ruptured fusiform dissecting aneurysm of the distal ICA, which was successfully treated using an endovascular ICA trapping with a manual ICA compression test instead of BTO.

Acute Thrombotic Occlusion of Left Internal Jugular Vein Compressed by Bypass Graft for Thoracic Endovascular Aortic Repair Debranching Procedure

  • Sim, Hyung Tae;Beom, Min Sun;Kim, Sung Ryong;Ryu, Sang Wan
    • Journal of Chest Surgery
    • /
    • 제47권6호
    • /
    • pp.552-555
    • /
    • 2014
  • Thoracic endovascular aortic repair has become a widespread alternative treatment option for thoracic aortic aneurysm. The debranching of arch vessels may be required to provide an acceptable landing zone for an endovascular stent graft. We report a case where the bypass graft used in the thoracic endovascular aortic repair procedure compressed the left internal jugular vein, causing acute thrombotic occlusion.

Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting

  • Lee, Jong Hyeok;Sohn, Hee Eon;Chung, Seung Young;Park, Moon Sun;Kim, Seong Min;Lee, Do Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권4호
    • /
    • pp.316-320
    • /
    • 2015
  • Objective : The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. Methods : From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid artery stenosis ${\geq}70%$ were treated with CAS with embolic protection device in single center. All patients underwent post-CAS diffusion-weighted magnetic resonance imaging (DW-MRI) to detect new ischemic lesions. We compared clinical outcomes and postprocedural embolization rates. Results : CAS was performed in all 61 patients. Distal filter protection success rate was 96.6% (28/29), whose mean age was 70.9 years, and mean stenosis was 81%. Their preprocedural infarction rate was 39% (11/28). Subsequent DW-MRI revealed 96 new ischemic lesions in 71% (20/28) patients. In contrast, the proximal balloon occlusion device success rate was 93.8% (30/32), whose mean age was 68.8 years and mean stenosis was 86%. Preprocedure infarction rate was 47% (14/30). DW-MRI revealed 45 new ischemic lesions in 57% (17/30) patients. Compared with distal filter protection device, proximal balloon occlusion device resulted in fewer ischemic lesions per patient (p=0.028). In each group, type of stent during CAS had no significant effect on number of periprocedural embolisms. Only 2 neurologic events occurred in the successfully treated patients (one from each group). Conclusion : Transfemoral CAS with proximal balloon occlusion device achieves good results. Compared with distal filter protection, proximal balloon occlusion might be more effective in reducing cerebral embolism during CAS.