• Title/Summary/Keyword: Stent occlusion

Search Result 92, Processing Time 0.026 seconds

Unexpected Detachment of Solitaire Stents during Mechanical Thrombectomy

  • Kim, Sung Tae;Jin, Sung-Chul;Jeong, Hae Woong;Seo, Jung Hwa;Ha, Sam Yeol;Pyun, Hae Wook
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.6
    • /
    • pp.463-468
    • /
    • 2014
  • Objective : Unexpected Solitaire stent detachment can occur during mechanical Solitaire thrombectomy. The purpose of this study was to retrospectively evaluate the influencing factors causing unexpected Solitaire stent detachment and the clinical outcomes. Methods : Between October 2011 to December 2013, 232 cases of mechanical Solitaire thrombectomy for acute ischemic stroke were performed in 3 stroke centers. During this period, we encountered unexpected Solitaire stent detachments during mechanical Solitaire thrombectomies in 9 cases. Results : Solitaire stents unexpectedly detached in 9 cases (3.9%) during the retrieval of Solitaire stents. The median patient age was 76 years. The occlusion sites of the unexpected stent detachment were the proximal middle cerebral artery (MCA) in 7 cases and the internal carotid artery in 2 cases. The sizes of the stents that unexpectedly detached were $6{\times}30$ mm in 7 cases, $5{\times}30$ mm in 1 case, and $4{\times}20$ mm in 1 case. Four patients had unexpected detachment at the first retrieval, 1 patient at the second, 3 patients at the third, and 1 patient at the fifth. In all of the cases of unexpected detachment at the first retrieval, the stent deployment site was the proximal MCA. After detachment, a proximal marker of the Solitaire stent was observed in 3 patients. However, no marker was visible in the remaining 6 patients. Conclusion : Unexpected Solitaire stent detachment should be considered in the first instance of stent retrieval for a relatively large-diameter stent, especially in elderly patients with MCA occlusions.

Solitaire AB Stent-Assisted Coiling of Wide-Neck Micro Aneurysms

  • Li, Xue-dong;Qin, Jun;Xiao, Zhen-yong;Feng, Yi;Chen, Jia-kang
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.341-345
    • /
    • 2016
  • Objective : Solitaire AB stent-assisted coiling facilitates the endovascular treatment of wide-necked intracranial aneurysms. We present our experience of coiling the micro-aneurysms of wide-neck with Solitaire AB stent assisting in a single center. Methods : Thirty-one Solitaire AB stents were used to treat via endovascular approach patients with 31 wide-neck micro aneurysms in a single center in China. Technical and clinical complications were recorded. Modified Rankin Scale was used to evaluate the patients' conditions via clinic and telephone follow-up. Results : The mean width of aneurysm sac was $2.30{\pm}0.42mm$, and the mean diameter of aneurysm neck was $2.83{\pm}.48mm$. Complete occlusion was achieved in 28 aneurysms (90.32%); neck remnant was seen in 3 aneurysms (9.68%). Technical and clinical complications related to the procedure were encountered in four patients (12.5%). Two patients died (6.25%). No patient had a permanent deficit. Conclusion : Solitaire AB stent was a safe and efficiency tool in assisting coiling of micro aneurysms with wide neck, but may be not suitable for a blaster-like one. Mid- and long-term follow-up will be required to elucidate the impact of the Solitaire AB stent on recanalization rate.

Long-Term Outcomes of Stenting on Non-Acute Phase Extracranial Supra-Aortic Dissections

  • Jiang, Yeqing;Di, Ruoyu;Lu, Gang;Huang, Lei;Wan, Hailin;Ge, Liang;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.422-429
    • /
    • 2022
  • Objective : Extracranial supra-aortic dissections (ESADs) with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke. Endovascular stenting to reconstruct non acute phase ESADs (NAP-ESADs) is an alternative to anticoagulant or antiplatelet therapy. However, its feasibility, safety and efficacy of stenting in NAP-ESADs is unclear. This study aims to investigate the long-term outcomes of the feasibility, safety and efficacy of stenting in NAP-ESADs. Methods : Seventy-four patients with 91 NAP-ESAD vessels with severe stenosis, occlusion and/or pseudoaneurysm presents potential risk of stroke who underwent stent remodeling were enrolled into this respective study from December 2008 to March 2020. Technical success rate, complications, clinical and angiographic results were harvested and analyzed. Results : Success rate of stent deployment was 99% (90/91) with no procedural mortality or morbidity. Transient ischemic attack occurred in three patients during operation (4.1%, 3/74). Asymptomatic embolisms of distal intracranial vessels were found in two patients (2.7%, 2/74). One hundred and forty-two stents deployed at 85 carotid (135 stents) and six vertebral (seven stents) vessels. Six stent types (Wingspan, 28/135, 20.7%; Solitaire, 10/135, 7.4%; Neuroform, 8/135, 5.9%; LVIS, 2/135, 1.5%; Precise, 75/135, 55.6%; Acculink, 12/135, 8.9%) were deployed at carotid arterial dissection while two types (Wingspan, 5/7, 71.4%; Solitaire 2/7, 28.6%) at vertebral arterial dissection. Digital subtracted angiography (56%, 51/91), computational tomography angiography (41.8%, 38/91) and high resolution magnetic resonance imaging (2.2%, 2/91) were adopted for follow up, with a mean time of 17.2±15.4 months (5-77). All patient modified Rankin Scale scores showed no increase at discharge or follow-up. Angiographically, dissections in 86 vessels in 69 patients (94.5%, 86/91) were completely reconstructed with only minor remnant dissections in four vessels in four patients (4.4%, 4/91). Severe re-stenosis in the stented segment required re-stenting in one patient (1.1%, 1/91). Conclusion : Stent remodeling technique provides feasible, safe and efficacious treatment of ESADs patients with severe stenosis, occlusion and/or pseudoaneurysm.

Clinical Characteristics and Treatment Outcomes of Patients with Unresectable Cholangiocarcinoma in Thailand: Are there Differences Dependent on Stent Type?

  • Prachayakul, Varayu;Chaisayan, Suthasinee;Aswakul, Pitulak;Deesomsak, Morakod
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.529-532
    • /
    • 2013
  • Cholangiocarcinoma, though very rare in Western countries, is one of the commonest liver malignancies in Southeast Asia, especially in Thailand. More than half of the patients present with advanced stage disease. Given the poor treatment outcomes of adjuvant therapeutic options, many patients undergo only biliary drainage for palliative treatment. Clinical characteristics and treatment outcomes after biliary stenting were here analyzed for a total of 224 uresectable cholangiocarcinoma cases, 58.9% in men. The mean age was 61.5 years. Hilar involvement was the most common location. The patients underwent biliary drainage using plastic and metallic stents equally, early stent occlusion being encountered in 21.4% and 10.7%, respectively. The median survival time was 4.93 months for patients who received plastic and 5.87 months for patients who received metallic stents.

Treatment of Internal Carotid Artery Dissections with Endovascular Stent Placement: Report of Two Cases

  • Deok Hee Lee;Seung Ho Hur;Hyeon Gak Kim;Seung Mun Jung;Dae Sik Ryu;Man Soo Park
    • Korean Journal of Radiology
    • /
    • v.2 no.1
    • /
    • pp.52-56
    • /
    • 2001
  • Extracranial carotid artery dissection may manifest as arterial stenosis or occlusion, or as dissecting aneurysm formation. Anticoagulation and/or antiplatelet therapy is the first-line treatment, but because it is effective and less invasive than other procedures, endovascular treatment of carotid artery dissection has recently attracted interest. We encountered two consecutive cases of trauma-related extracranial internal carotid artery dissection, one in the suprabulbar portion and one in the subpetrosal portion. We managed the patient with suprabulbar dissection using a self-expandable metallic stent and managed the patient with subpetrosal dissection using a balloon-expandable metallic stent. In both patients the dissecting aneurysm disappeared, and at follow-up improved luminal patency was observed.

  • PDF

Initial Experience of ACE68 Reperfusion Catheter in Patients with Acute Ischemic Stroke Related to Internal Carotid Artery Occlusion

  • Jang, Hyoung-Gyu;Park, Jung-Soo;Lee, Jong-Myong;Kwak, Hyo-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.545-550
    • /
    • 2019
  • Objective : Penumbra ACE68 reperfusion catheter is a new large bore aspiration catheter used for reperfusion of large vessel occlusion. The objective of this study was to investigate the efficacy of this catheter in comparison to that of previous Penumbra catheters in patients with acute ischemic stroke related to internal carotid artery (ICA) occlusion. Methods : Data of all eligible patients who received endovascular treatment (EVT) for ICA occlusion using Penumbra aspiration catheters between January 2015 and December 2018 were retrospectively reviewed. After dividing into two groups according to use of penumbra ACE68, baseline characteristics of patients, successful recanalization rate, puncture to recanalization time, and switch to stent base technique rate were assessed. Successful recanalization was defined by a thrombolysis in cerebral infarction (TICI) score ${\geq}2b$ and favorable functional outcome was defined according to modified Rankin scale (score, 0-2). Results : ACE68 reperfusion catheter was used in 29 of 75 eligible patients (39%). The puncture to recanalization time was significantly shorter ($26{\pm}18.2$ minutes vs. $40{\pm}24.9$ minutes, p=0.011) and the rate of switch to stent-based retrieval was significantly lower (3% vs. 20%, p=0.046) in ACE68 catheter group. Moreover, although not statistically significant, the successful recanalization rate was higher (83% vs. 76%, p=0.492) in ACE68 catheter group. Favorable functional outcome was observed in 48% of patients treated with ACE68 reperfusion catheter and in 30% of patients treated using other Penumbra systems (p=0.120). Baseline Alberta Stroke Program Early CT Scores ${\geq}8$ (odds ratio [OR], 9.74; 95% confidence interval [CI], 1.72-54.99; p=0.010) and successful recanalization (OR, 10.20; 95% CI, 1.13-92.46; p=0.039) were independent predictors of favorable outcome. Conclusion : EVT using ACE68 reperfusion catheter can be considered a first-line therapy in patients with acute ICA occlusion as it can achieve rapid recanalization and reduce the frequency of conversion to stent-retrieve therapy.

Angiographic and Clinical Factors Related with Good Functional Outcome after Mechanical Thrombectomy in Acute Cerebral Artery Occlusion

  • Park, Jong Hyuk;Han, Young Min;Jang, Kyeong Sool;Yoon, Wan Soo;Jang, Dong Kyu;Park, Sang Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.192-196
    • /
    • 2015
  • Objective : The aim of this study is to investigate good prognostic factors for an acute occlusion of a major cerebral artery using mechanical thrombectomy. Methods : Between January 2013 to December 2014, 37 consecutive patients with acute occlusion of a major cerebral artery treated by mechanical thrombectomy with stent retrievers were conducted. We analyzed clinical and angiographic factors retrospectively. The collateral flow and the result of recanalization were sorted by grading systems. Outcome was assessed by National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) at 90 days. We compared the various parameters between good and poor angiographic and clinical results. Results : Twenty seven patients demonstrated good recanalization [Thrombolysis in Cerebral Infarction (TICI) 2b or 3] after thrombectomy. At the 90-day follow up, 19 patients had good (mRS, 0-2), 14 had moderate (3-4) and four had poor outcomes (5-6). The mRS of older patients (${\geq}75years$) were poor than younger patients. Early recanalization, high Thrombolysis in Myocardial Infarction risk score, and low baseline NIHSS were closely related to 90-day mRS, whereas high TICI was related to both mRS and the decrease in the NIHSS. Conclusion : NIHSS decreased markedly only when recanalization was successful. A good mRS was related to low initial NIHSS, good collateral, and early successful recanalization.

Analysis of failed mechanical thrombectomy with a focus on technical reasons: Ten years of experience in a single institution

  • Sinho Park;Dong Hoon Lee;Jae Hoon Sung;Seung Yoon Song
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.1
    • /
    • pp.13-18
    • /
    • 2023
  • Objective: Mechanical thrombectomy (MT) is an effective treatment for patients suffering from acute ischemic stroke secondary to large vessel occlusion. However, recanalization failure rates of interventions were about 20% in literature studies. We report our experience of unsuccessful MT with a focus on technical reasons. Methods: From December 2010 to June 2021, six hundred eight patients with acute ischemic stroke due to large artery occlusion received MT using a stent retriever with or without an aspiration catheter in our institution. We divided the reasons for failure into six categories. We analyzed the reasons for failure by dividing our experience time into 3 periods. Results: A total of 608 cases of thrombectomy for large vessel occlusion were identified in the study period. The successful recanalization rate was 90.4%. In most of the cases (20/57, 35%), the thrombus persisted despite several passes, and the second most common cause was termination of the procedure even after partial recanalization (10/57, 18%). Similar proportions of in-stent occlusion, distal embolization, and termination due to vessel rupture were observed. On analysis of three periods, the successful recanalization rate improved over time. Conclusions: MT fails due to various reasons, and intracranial artery stenosis is the main cause of MT failure. With the development of rescue techniques, the failure rate has gradually decreased. Further development of new devices and techniques could improve the recanalization rates.

Endovascular Graft-Stent Placement for Treatment of Traumatic Carotid Cavernous Fistulas

  • Choi, Beom-Jin;Lee, Tae-Hong;Kim, Chang-Won;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.6
    • /
    • pp.572-576
    • /
    • 2009
  • Detachable balloon-based endovascular fistula occlusion is a widely accepted treatment for traumatic carotid cavernous fistulas (CCF). However, more recently coils have been used to obliterate the lesion, especially in case detachable balloon is not available. We failed balloon-assisted coil embolization for CCF because of large fistulas and herniation of coil loops into the parent artery. The authors describe our experiences of balloon-expandable graft-stents to treat CCF, and place emphasis on arterial wall reconstruction. Three traumatic CCF patients were treated using a graft-stent with/without coils, and underwent angiographic follow-up to evaluate the patency of the internal carotid artery (ICA). In all cases, symptoms related to CCF regressed after stent deployment and did not recur during follow-up. Follow-up angiography revealed good patency of the ICA in all patients. Graft-stents should be considered as an alternative means of treating CCF and preserving the parent artery by arterial wall reconstruction especially in patients with a fistula that cannot be successfully occluded with detachable balloons or coils.

Bilateral Superior Cerebellar Artery Infarction after Stent-Angioplasty for Internal Carotid Artery Stenosis

  • Kim, Jung-Hwan;Lee, Jong-Hyeog;Jo, Kwang-Deog;You, Seung-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.239-242
    • /
    • 2013
  • Spontaneous bilateral cerebellar infarction in the territory of the superior cerebellar arteries is extremely rare. Occasionally there have been reports of bilateral cerebellar infarction due to vertebrobasilar atherosclerotic occlusion or stenosis, whereas no report of bilateral cerebellar infarction due to complicated hemodynamic changes. In this report, we present a patient with bilateral cerebral infarctions related to stenoses of bilateral internal carotid arteries, in whom vertebrobasilar system was supplied by multiple collaterals from both posterior communicating arteries and right external carotid artery. We performed stent-angioplasty of bilateral internal cerebral arterial stenosis, and then acute infarction developed on bilateral superior cerebellar artery territories. The authors assumed that the infarction occurred due to hemodynamic change between internal carotid artery and external carotid artery after stent-angioplasty for stenosis of right internal carotid artery.