• Title/Summary/Keyword: Stent graft

Search Result 102, Processing Time 0.026 seconds

Management for the Newly-Onset Aneurysmal Dilation of the Distal Aorta after an Endovascular Stent Graft Procedure for the Patient with Acute Aortic Dissection Type IIIb (급성 하행대동맥 박리증에서 스텐트-그라프트 삽입 후 새로이 발생한 원위부 대동맥류에 대한 인조혈관 대치술 치험 1예)

  • 이길수;방정희;조광조;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.427-430
    • /
    • 2003
  • The surgical managements for the complicated aortic disease is still one of most challenging fields for the cardiac surgeons. The endovascular stent graft procedure has been tried recently to avoid serious complications caused by traditional graft replacement technique. However, indications for the procedures or management methods for the complications have not been clearly elucidated so far. We report a case of successful management for the newly-onset aneurysmal dilation of the distal aorta after an endovascular stent graft procedure in a patient with acute aortic dissection type IIIB.

Serial Vascular Responses of Balloon-Expandable Stent With Biodegradable Film-Type Graft in a Rabbit Iliac Artery Dissection Model (BioGard Study)

  • Sang Min Park;Kyung-Chan Choi;Byeong Han Lee;Sang Yol Yoo;Christopher Y. Kim
    • Korean Circulation Journal
    • /
    • v.54 no.8
    • /
    • pp.499-512
    • /
    • 2024
  • Background and Objectives: Arterial dissection during endovascular therapy rarely occurs but can be lethal. A fabric-based covered graft stents yield poor clinical outcomes. A novel balloon-expandable stent with biodegradable film graft for overcoming these issues was evaluated in a rabbit iliac artery model. Method: Eighteen rabbits with iliac artery dissections were induced by balloon over-inflation on angiography (Ellis type 2 or 3) and treated using the test device (3.0×24 mm). Subsequently, survived twelve animals underwent histologic examinations and micro-computed tomography (CT) at 0, 2, 4, and 8 weeks and 3, 6, 9, and 12 months and angiography at one-year. Results: There were no adverse cardiovascular events during the one-year. Early-stage histologic examination revealed complete sealing of disrupted vessels by the device, exhibiting mural hematoma, peri-stent red thrombi, and dense infiltration of inflammatory cells. Mid- and long-term histologic examination showed patent stents with neointimal hyperplasia over the stents (% area stenosis: 11.8 at 2 weeks, 26.1 at 1 month, 29.7 at 3 months, 49.2 at 9 months, and 51.0 at 1 year), along with mild peri-strut inflammatory response (Grade: 1-2 at mid-term and 0-1 at long-term). The graft film became scarcely visible after six months. Both CT and angiography revealed no instances of thrombotic occlusion or in-stent restenosis (% diameter stenosis: 5.7 at 2 weeks, 12.3 at 1 month, 14.2 at 3 months, 25.1 at 9 months, and 26.6 at 1 year). Conclusions: The novel balloon-expandable stent with a biodegradable film graft demonstrates feasibility in managing severe artery dissection and preventing lethal vascular events in animal model.

Non-Anastomotic Rupture of a Woven Dacron Graft in the Descending Thoracic Aorta Treated with Endovascular Stent Grafting

  • Lee, Youngok;Kim, Gun-Jik;Kim, Young Eun;Hong, Seong Wook;Lee, Jong Tae
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.465-467
    • /
    • 2016
  • The intrinsic structural failure of a Dacron graft resulting from the loss of structural integrity of the graft fabric can cause late graft complications. Late non-anastomotic rupture has traditionally been treated surgically via open thoracotomy. We report a case of the successful use of thoracic endovascular repair to treat a Dacron graft rupture in the descending aorta. The rupture occurred 20 years after the graft had been placed. Two stent grafts were placed at the proximal portion of the surgical graft, covering almost its entire length.

Stent Graft Repair of Penetrated Injury of the Common Carotid Artery

  • Kim, Soon Jin;Ryu, Sang Woo;Chekar, Jaykey;Kim, Yong Tae;Seo, Bo Ra
    • Journal of Trauma and Injury
    • /
    • v.29 no.4
    • /
    • pp.172-175
    • /
    • 2016
  • Penetrated injury of common carotid artery (CCA) is rare and extremely lethal. Carotid artery injury tends to bleed actively and potentially occlude the trachea. It can cause fatal neurological complications. An accurate diagnosis and adequate treatment are very needed to the successful outcome of the penetrating vascular injury in zone 1, 2, and 3 of the neck. Open surgical treatment is more invasive and complicated than endovascular treatment. We experienced a case with penetrating injury in neck zone 2. Here, we report the case successfully treated with endovascular stent graft technique.

The Use of Rapid Ventricular Pacing to Facilitate Stent Graft Deployment in the Distal Aortic Arch (빠른 심실유도를 이용한 흉부대동맥류의 혈관 내 스텐트 그라프트 치료)

  • Kong, Joon-Hyuk;Koo, Yang-Hee;Lee, Yoon-Ji;Hur, Jin;Kim, Duk-Sil;Kim, Sung-Wan
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.769-773
    • /
    • 2010
  • Systemic hypotension has been traditionally used to facilitate deployment of thoracic stent grafts. Decreasing blood pressure with vasodilating agents further increases cardiac output and, consequently, the cardiac output-mediated windsock effect during deployment. Use of rapid ventricular pacing reduces the windsock effect during stent graft deployment and allows the graft to appose to the aortic wall under zero cardiac output, thus minimizing aortic wall shear stress. In this case we report the use of transvenous rapid ventricular pacing, a safe and reproducible technique to allow precise deployment of a Valiant Captivia stent graft in the distal thoracic arch for a saccular thoracic aneurysm.

Use of Percutaneous Endovascular Stent Graft in Patients with Thoracic Aortic Aneurysm (흉부대동맥류 환자에서 경피적 인조혈관 스텐트의 사용)

  • Geon Yong Sun;Baek Wan Ki;Yoon Yong Han;Kim Young Sam;Kim Kwang Ho;Kim Joung Taek
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.157-161
    • /
    • 2006
  • Use of endovascular stent-graft in aortic aneurysm disease is now accepted as an alternative treatment to surgery. We successfully treated two patients with high risk of thoracic aortic aneurysm with percutaneous endovascular stent-graft. Three and ten months follow up chest CT showed obliteration of aneurysm and there was no complication after stent grafting.

A Case of Aortobronchial Fistula with Massive Hemoptysis after Aortic Stent Graft (대량객혈로 내원한 대동맥기관지루 1예)

  • Hwang, Sang Yon;Chung, Jae Ho;Park, Moo Suk;Kim, Hong Jeong;Hahn, Chang Hoon;Moon, Jin Wook;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Won, Jong Yoon;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.4
    • /
    • pp.405-410
    • /
    • 2004
  • Aortobronchial fistula may cause a massive fatal hemoptysis. Recently prosthetic aortic graft insertion or endovascular stent graft is a cause of aortobronchial fistula. We report a rare case of hemoptysis from a fistula between an aortic arch aneurysm and the left main bronchus in a patient who had undergone an endovascular stent graft in pseudoaneurysm of descending thoracic aorta one year before.

Hemodynamic Consideration for Endoleak and Aneurysm Size Change after the Stent-Graft Application of Aortic Aneurysm

  • Park, Jea-Hyung;Jae, Hwan-Joon;Lee, Whal;Chung, Jin-Wook
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.2
    • /
    • pp.10-15
    • /
    • 2004
  • Purpose: In the treatment of aortic aneurysm, endovascular stent-graft application has become an established method of treatment. To observe the outcomes of the procedure as the size change of aneurysm in relation with endoleak, a retrospective analysis was done for the consecutive cases who undertook the procedure. Materials & Method: Stent-graft was applied to the aortic aneurysm in 33 patients. The location of the aneurysm was thoracic in 11 patients and abdominal in 22 patients. CT angiographic was done for the follow-up evaluation to analyze the aneurysm size and the presence of endoleak. Results: Technical success rate was 97% (32/33). The primary success rate without endoleak was 84% (28/33). The secondary success was 90% (30/33). During the follow-up period of 3 months to 7years and 6months in 26 patients, a secondary endoleak developed in 5 cases. Post-implantation syndrome developed in 17 cases (51%). Among the 14 cases with follow-up imaging data for size, endoleak was negative in 10 cases. The aneurysm decreased in 5 cases, stable in size in 4 cases and enlarged in one case (10%).Among the 4 cases with endoleak positive, the aneurysm enlarged in two cases (50%). Conclusion: In the stent-graft application for aortic aneurysm, there is high chance of decrease of aneurysm size in those cases with endoleak negative. However, the aneurysm may increase and eventually rupture in the cases with en do leak positive. Close observation with CT angiography is necessary for the evaluation for the presence of endoleak and size change.

  • PDF

One-Stage Management of Ascending Aorta Replacement and Percutaneous Endovascular Repair for Ascending and Descending Aortic Aneurysms - A case report - (상행 및 하향대동맥류에 대한 상행대동맥 치환술 및 경피적 Stent Graft 삽입의 단일 단계 치료 - 1예 보고 -)

  • Kim, Chang-Young;Chang, Woo-Ik;Kim, Yeon-Soo;Park, Kyung-Taek;Ryoo, Ji-Yoon
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.524-527
    • /
    • 2009
  • A stent graft has been accepted as an alternative method for treating aortic diseases or to reduce the extent of surgery. We report here on a one-stage Management of Ascending Aorta Replacement and Percutaneous Endovascular Repair for the seperate aneurysmal lesions on the ascending and descending aorta.

Successful Endovascular Management of Intraoperative Graft Limb Occlusion and Iliac Artery Rupture Occurred during Endovascular Abdominal Aortic Aneurysm Repair

  • Lim, Jae Hong;Sung, Yong Won;Oh, Se Jin;Moon, Hyeon Jong;Lee, Jeong Sang;Choi, Jae-Sung
    • Journal of Chest Surgery
    • /
    • v.47 no.1
    • /
    • pp.71-74
    • /
    • 2014
  • For high-risk patients, endovascular aortic aneurysm repair (EVAR) is a good option but may lead to serious complications, which should be addressed immediately. A 75-year-old man with a history of abdominal surgery underwent EVAR for an aneurysm of the abdominal aorta and iliac arteries. During EVAR, iliac artery rupture and graft limb occlusion occurred, and they were successfully managed by the additional deployment of an iliac stent graft and balloon thrombectomy, respectively. We, herein, report a rare case of the simultaneous development of the two fatal complications treated by the endovascular technique.