• Title/Summary/Keyword: Steep front of wave flashover test

Search Result 4, Processing Time 0.023 seconds

A Study on the Performance Evaluation of Transmission Suspension Insulators (송전용 현수애자의 성능평가에 관한 연구)

  • Song, Il-Geun;Kim, Chan-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.406-411
    • /
    • 2000
  • This paper presents the results of performance confirmation tests for domestic 20 [Ton] transmission suspension insulators which will be widely utilized in transmission lines. The new test methods such as power arc test, steep-front-of-wave flashover voltage test, and etc. which have been only utilized for the distribution insulators were applied in transmission suspension insulators. The properties of metal and cement used in the 20 [Ton] transmission insulators were also evaluated by the various analysis techniques. Based on the results, we evaluated the performance of the transmission suspension insulators.

  • PDF

A Study on the Electric Performance of Porcelain Insulator with Al2O3 Addition in Transmission Line (Al2O3 첨가에 따른 송전용 현수애자의 전기적 성능 평가 연구)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Lee, Dong-Il;Choi, Yeon-Gyu;Cho, Han-Goo;Han, Se-Won;Park, Young-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.96-103
    • /
    • 2005
  • To analyze the reason of aging deterioration in transmission line insulators, we performed a various kind of test and investigated mechanical and electrical characteristics of insulators. Test samples consisted of K-1989(36,000lbs), K-1995(36,000lbs) and K-2001(36,000lbs) type insulators which have been used in domestic 154 kV transmission lines. As a result of this test, the facts turned out K-2001 insulator which contain 17 wt.% alumina has better physical characteristics than K-1989 insulator which contain 8 wt% alumina. Relativity density and fracture toughness of K-1989 porcelain are 94.2 % and 1.4 MPa\ulcornerm$^{1}$2// but relativity density and fracture toughness of K-2001 porcelain are 96 % and 1.7 MPa\ulcornerm$^{1}$2//. K-2001 insulators show a good performance not only in a physical property test but also in power arc test and steep front of wave flashover test which is performed to evaluate electrical characteristics.

The Inner Defect Detection of Suspension Insulators by Lightning Impulse (뇌 임펄스를 이용한 현수애자의 내부결함 검출)

  • 송일근;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.83-90
    • /
    • 1995
  • This paper analyzed the electrical field strength of porcelain suspension insulator used various testing methods in order to present the causes and countermeasure for the puncture failure by the inner minute defect. A power frequency puncture test and a step-front-of-wave flashover voltage test were conducted. The failed specimen of these samples was analyzed material characteric observed the cross-sectional picture by the scanning electron microscope, and tested the autoclave expansion for the portland cement using the metal bond agent. The porcelain made a progress the failure by the thermal expansion coefficient of the different material. The inner detecting technique on behalf of the puncture failure protection is presented such as the steep-front-of-wave flashover voltage test.

  • PDF

A Study on the breakdown reduction of porcelain insulators (자기제 애자의 절연파괴 감소대책 연구)

  • Song, I.K.;Park, K.P.;Kim, Y.L.;Kim, K.W.;Kwak, H.R.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1042-1044
    • /
    • 1995
  • This paper provides the results and analyses of investigations into porcelain suspension insulators failures on the KEPCO system. The high failure rate of suspension insulators on distribution lines has been attributed to the volume expansion of the cement, the insulation puncture breakdown of the porcelain and the power arc failure. The utility must use only the good insulators and at least reduce the insulator failure rate. So, this paper recommends that the utility make test criteria(cement expansion test, steep front-of-wave flashover voltage test and power arc test. etc) on the suspension insulators.

  • PDF