• Title/Summary/Keyword: Steel-Fibers

Search Result 577, Processing Time 0.029 seconds

A Study on the Shear Behavior of Reinforced Hooked Steel Fibrous Concrete Beam (훅트강섬유보강철근콘크리트보의 전단거동에 관한 연구)

  • 심종성;이차돈;김규선;오홍섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.224-228
    • /
    • 1995
  • Addition of hooked steel fibers into the cementitious materials enhanced shear resistance and consequently improves structural behavior and shear strength of reinforced hooked steel fibrous concrete beam(RHSFCB) under the shear forces. Experimental observations were made on the main parameters effecting structural behavior of RHSFCB in this study. The volume fractions of fibers, shear span to depth ratios, and spacings of stirrups were taken into account as the main parameters. Some equations reported in the literatures, regarding the predictions of the shear strength of RHSFCB have been evaluated statistically based on the total number of 95 test results on RHSFCB failed in shear on shear-flexural mode.

  • PDF

An Experimental Study on the Strengths and Flexural Deformation of Steel Fiber Reinforced Concrete According to the Steel Fiber-Type (강섬유의 종류에 따른 강섬유보강 콘크리트의 강도 및 휨변형 특성에 관한 실험적 연구)

  • 박승범;김의성;홍석주;강형선;권혁준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.328-334
    • /
    • 1996
  • This report is the results of an experimental study on the relative effectiveness of different types of steel fiber in concrete. The fibers considered in the study were straight-indent and hooked-collated with aspect ratios of about 50~100. A fiber volume of 0~2 percent was used throughout this investigation. The fresh fibrous mixes were characterized by the slump and vebe-time, and the hardened materials by their compressive and flexural load-deflection relationships. Hooked fibers were found to be more effective than straight ones in improving the strength and energy absorption of concrete.

  • PDF

A Study on the Long-term Deformation of Steel Fiber Reinforced Concrete Utilizing By-Products of Industry (산업부산물을 사용한 강섬유보강 콘크리트의 장기변형 특성에 관한 연구(I))

  • 박승범;김의성;윤의식;홍석주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.308-314
    • /
    • 1997
  • Shrinkage and creep are the fundamental properties of concrete. These long term deformations can be seen as bothersome(increased deflection) or can be seen as reduction of compressive stress of prestressed concrete. Steel fibers advance the mechanical properties of concrete:tensile strength, ductility, flexural strength, fracture toughness, and post-cracking resistance, etc...Silica fume is pozzolanic material which combines with hydrated lime to generate silicate materials which increase the compressive strength and reduce somewhat the creep of concrete. This paper is the result of the long-term deformation by silica fume and steel fibers with varying percentages.

  • PDF

A Study on the flexural Behavior of Ultra-Strength Steel Fiber Reinforced Concrete (초고강도 강섬유 보강 콘크리트의 휨특성에 관한 연구)

  • Ryu, Gum-Sung;Park, Jung-Jun;Kang, Su-Tea;Koh, Kyung-Taeg;Kim, Sung-Wook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.333-336
    • /
    • 2005
  • This paper presents a comparative evaluation of eight different types of steel fibers used as reinforcing material in concrete beams. The fibers which used ultra-strength steel fiber reinforced concrete were fiber length of 30 to 60mm, aspect ratio of 43 to 86, W/B ratio 0.16 to 0.30, fiber types of both ends hooked and straight shape and fiber volume fraction of 1 to 5$\%$. As for the test results, it estimated the influence of fiber volume, length and aspect ratio on the mechanical properties of high toughness concrete, the mechanical properties improved according to increase fiber volume, to increase aspect ratio and to long fiber length. And the resonable fiber volume in high toughness concrete was analyzed 2$\%$ based on the results of mechanical properties.

  • PDF

Flexural Performance and Cracking Resistance of Continuous Composite Slab using Micro Steel Fibers (마이크로 강섬유 콘크리트를 적용한 연속 합성슬래브의 휨 및 균열 저항성능)

  • Hwang, Hyeon-Jong;Park, Hong-Gun;Hong, Geon-Ho;Kim, Gap-Deug;Choi, Se-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.387-397
    • /
    • 2015
  • In the present study, to enhance the constructability, a composite slab system using deck plate and micro steel fiber concrete was studied. In the proposed slab system, on-situ re-bar placement is not required. Steel fibers replace the temperature reinforcement. The present study focused on the crack control at the slab top in the continuous composite slab without spliced bars. Eight continuous slabs with various parameters were tested under vertical loading. The test parameters were the amount and types of micro steel fibers, types of deck plate, and the use of top bars in the continuous slab. To evaluate the crack resistance of the slabs, crack widths were measured in the continuous slabs. The test results showed that although the top spliced bars were not used, cracking were restrained by large flexural stiffness of the composite sections.

Evaluation of tensile properties of SFRC for TBM tunnel segment (TBM 터널 세그먼트용 강섬유보강 콘크리트의 인장특성 평가)

  • Moon, Do-Young;Chang, Soo-Ho;Bae, Gyu-Jin;Lee, Gyu-Pil
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.3
    • /
    • pp.247-260
    • /
    • 2012
  • In order to reduce the amount of steel reinforcements in TBM tunnel segments, the use of Steel Fiber Reinforced Concrete(SFRC) is being tried. The steel fibers with higher aspect ratio than that used in tunnel shotcrete are preferred to compensate the deficiency in tensile strength of the segments. In this study, the tensile properties of SFRC with aspect ratio of steel fibers equal to 80 were evaluated through flexural test and Double Punch Test. In the results of flexural test, flexural strengths of the SFRC were increased about 30%~150% thanks to bond of steel fibers used to concrete and could be properly predicted by the equation proposed by Oh(2008). There was a great difference in the estimated direct tensile strengths of the SFRC by the equations presented in ACI and RILEM. It was found that the Double Punch Test could be suitable methodology to estimate the direct tensile strength presented in RILEM of the SFRC.

Comparative Study on the Flexural Performance of Concrete Reinforced with Polypropylene and Steel Fibers (폴리프로필렌 및 강섬유 보강콘크리트의 휨 성능에 관한 비교 연구)

  • Cho, Baiksoon;Lee, Jong-Han;Back, Sung Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1677-1685
    • /
    • 2014
  • Short discrete fibers compounded with concrete can enhance the tensile resistance and ductility of concrete. Recently, the effectiveness of the reinforcement has increased according to the increasing length of steel fiber. However, the lengthening of steel fiber requires reducing the ratio of the fiber content to remain the workability and quality of concrete. Thus, the present study evaluated the flexural performance of fiber reinforced concrete with less than l.0% fiber volume ratios of steel fiber, 30mm and 60mm long, and polypropylene fiber, being evaluated as a good reinforcing material with chemical stability, long-term durability, and cost effectiveness. Concrete with more than 0.25% steel and 0.5% polypropylene fibers improved the brittle failure of concrete after reaching cracking strength. Concrete reinforced with polypropylene exhibited deflection-softening behavior, but that with more than 0.5% polypropylene delayed stress reduction and recovered flexural strength by 60 to 80% after cracking strength. In conclusion, concrete reinforced with more than 0.75% polypropylene could improve structural flexural performance. In particular, energy absorption capacity of reinforced concrete with 1.0% polypropylene fiber was similar to that with 0.5% and 0.7% steel fibers.

Stress-strain behavior and toughness of high-performance steel fiber reinforced concrete in compression

  • Ramadoss, P.;Nagamani, K.
    • Computers and Concrete
    • /
    • v.11 no.2
    • /
    • pp.149-167
    • /
    • 2013
  • The complete stress-strain behavior of steel fiber reinforced concrete in compression is needed for the analysis and design of structures. An experimental investigation was carried out to generate the complete stress-strain curve of high-performance steel fiber reinforced concrete (HPSFRC) with a strength range of 52-80 MPa. The variation in concrete strength was achieved by varying the water-to-cementitious materials ratio of 0.40-0.25 and steel fiber content (Vf = 0.5, 1.0 and 1.5% with l/d = 80 and 55) in terms of fiber reinforcing parameter, at 10% silica fume replacement. The effects of these parameters on the shape of stress-strain curves are presented. Based on the test data, a simple model is proposed to generate the complete stress-strain relationship for HPSFRC. The proposed model has been found to give good correlation with the stress-strain curves generated experimentally. Inclusion of fibers into HPC improved the ductility considerably. Equations to quantify the effect of fibers on compressive strength, strain at peak stress and toughness of concrete in terms of fiber reinforcing index are also proposed, which predicted the test data quite accurately. Compressive strength prediction model was validated with the strength data of earlier researchers with an absolute variation of 2.1%.

Effect of Volume Fraction and Length of Fiber on the Mechanical Properties of Fiber Reinforced Concrete (섬유보강 콘크리트의 역학적 특성에 대한 섬유 체적비와 길이의 영향)

  • Yang, Keun-Hyeok;O, Seung-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.1
    • /
    • pp.43-48
    • /
    • 2008
  • Fifteen concrete specimens were mixed and tested to explore the significance and limitation of appling the polyvinyl alcohol (PVA) fiber and steel fiber with end hook to concrete. Main parameters investigated were volume fraction and length of the fibers. The measured mechanical properties of fiber reinforced concrete are analyzed according to the equivalent fiber amount index explaining the adding amount and length of fibers. Test results showed that compressive strength of fiber reinforced concrete was higher than that of concrete with no fiber by $10{\sim}20%$. The normalized splitting tensile strength and flexural strength of PVA fiber reinforced concrete were similar to those of concrete with no fiber, whereas those of steel fiber reinforced concrete increased with the increase of the equivalent fiber amount index. In particular, much higher ductile behavior was observed in steel fiber reinforced concrete than in PVA reinforced concrete, indicating that the slope of descending branch of load-displacement relationship of steel fiber reinforced concrete decreased with the increase of the volume fraction and length of the fiber.

Influence of steel-fiber type and content on electrical resistivity of old-concrete

  • Uygunoglu, Tayfun;Topcu, Ilker Bekir;Simsek, Baris
    • Computers and Concrete
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Electrical resistivity is a property associated with both the physical and chemical characteristics of concrete. It allows the evaluation of the greater or lesser difficulty with which aggressive substances penetrate the concrete's core before the dissolution of the passive film process and the consequent reinforcement's corrosion begin. This work addresses the steel fiber addition to concrete with two types and various contents from 0% to 1.3%, correlating it with its electrical resistivity. To that effect, 9 different mixes of steel fiber reinforced concrete (SFRC) were produced. The electrical resistivity was evaluated on the on six years aged SFRC by direct measurement at different frequency from 0.1 kHz to 100 kHz. The results indicate that steel fiber content is strongly conditioned by the type and quantity of the additions used. It was also found that long type of fibers has more effect on decreasing the electrical resistivity of concrete than short fibers. Therefore, they increase the corrosion risk of concrete depending on fiber volume fraction and moisture percentage.