• 제목/요약/키워드: Steel stud

검색결과 240건 처리시간 0.027초

원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험 (Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube)

  • 이흥수;정철헌;최외호;김석기;유성근;김영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

Determining the effective width of composite beams with precast hollowcore slabs

  • El-Lobody, Ehab;Lam, Dennis
    • Structural Engineering and Mechanics
    • /
    • 제21권3호
    • /
    • pp.295-313
    • /
    • 2005
  • This paper evaluates the effective width of composite steel beams with precast hollowcore slabs numerically using the finite element method. A parametric study, carried out on 27 beams with different steel cross sections, hollowcore unit depths and spans, is presented. The effective width of the slab is predicted for both the elastic and plastic ranges. 8-node three-dimensional solid elements are used to model the composite beam components. The material non-linearity of all the components is taken into consideration. The non-linear load-slip characteristics of the headed shear stud connectors are included in the analysis. The moment-deflection behaviour of the composite beams, the ultimate moment capacity and the modes of failure are also presented. Finally, the ultimate moment capacity of the beams evaluated using the present FE analysis was compared with the results calculated using the rigid - plastic method.

리브형 슬래브를 갖는 유공합성보의 거동에 관한 실험적 연구 (Experimental Study on Behaviour of Composite Beams with Ribbed Slabs and Unreinforced Web Openings)

  • 김창호;박종원;김희구;이창섭;박준용
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.989-994
    • /
    • 2000
  • Nine tests to failure are performed on full-scale eight composite beams with unreinforced web opening having ribbed slabs with formed deck which are perpendicular to the steel section and one steel beam. The effects of slab width, reinforcing of stud, moving of rib, moment-shear ratio are studied. At the low M/V ratio, Vierendeel action around the high moment end of the opening is occurred and the large deflection across the opening and transverse cracking are occurred with increasing of applied load. As the M/V ratio increases, the relative deflection across the opening decreases. And at failure, full tensile strain are occurred at bottom T section of steel beam, and concrete crushes at the High Moment End of the opening. With narrow slabs, diagonal tension failure at the high moment end of the opening is occurred. And with wide slabs, rib punch-through failure is occurred near the high moment end of the opening. The implications for design are discussed.

철골 조립식주택 바닥판 진동 평가에 관한 연구 (A Study on Evaluation of Floor Vibration for Steel Frame Modular Housing)

  • 김종성;조민주;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.104-111
    • /
    • 2016
  • 최근 연구개발이 활발히 이루어지고 있는 철골 조립식주택은 공장에서 생산되고 현장에서 조립되는 건설방식의 특성으로 인해 일반 건축물의 철근콘크리트 바닥판과 같이 일체타설 시공되지 못하게 되며 부재 단면크기 감소 및 경량화 등으로 인해 거주자의 활동에 의한 바닥판의 수직진동 및 처짐이 사용성 평가 측면에서 중요한 문제가 될 수 있다. 따라서 이 연구에서는 대상 조립식주택에서 장변방향 보 중앙에 샛기둥이 설치된 모듈과 설치되지 않은 모듈을 대상으로 실무에서 일반적으로 사용되고 있는 AISC 설계지침서 11의 계산식(이하 AISC 계산식)을 이용하여 바닥판의 진동성능을 평가하고 범용해석프로그램을 이용한 해석결과와 비교를 통해 AISC 계산식의 적용성을 고찰하였다. 이를 토대로 샛기둥이 설치된 모듈의 바닥판에서 AISC 계산식과 해석결과의 오차가 크게 발생되는 구조적 원인을 분석하고 이를 고려하는 방안을 제시하였다. 또한 대상 조립식주택 바닥판에 대한 진동성능 향상방안을 변수로 해석모델을 수립하고 진동응답해석 및 경제성평가를 통해 진동성능과 경제성이 우수한 방안을 제시하였다.

개방형 유공강판 전단연결재로 보강된 강관말뚝머리의 휨거동에 관한 유한요소 해석 (Finite Element Analysis for Bending Performance of Steel Pipe Pile Cap with the Open Perforated Shear Connector)

  • 김영호;강재윤;유승운
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.4018-4023
    • /
    • 2010
  • 합성구조에서 강재와 콘크리트 사이의 경계면에 효과적인 응력전달과 합성거동을 유도하기 위하여 스터드, 채널, 유공강판 등이 사용된다. 많은 연구자들이 여러 종류의 전단연결재의 특성을 개선시키기 위해 많은 노력을 기울이고 있다. 본 연구에서는 말뚝구조물과 확대기초와의 합성을 위해 개방형 유공강판 전단연결재로 보강된 강관 말뚝머리의 휨거동을 분석하였다. 개방형 유공강판 전단연결재로 보강된 강관말뚝의 휨거동을 규명하고, 다양한 변수해석에서 요구되는 정보를 얻고자 유한요소해석 프로그램인 ABAQUS를 사용하여 비선형 유한요소 해석을 수행하였다.

Experimental testing of cold-formed built-up members in pure compression

  • Biggs, Kenneth A.;Ramseyer, Chris;Ree, Suhyun;Kang, Thomas H.-K.
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1331-1351
    • /
    • 2015
  • Cold-formed built-up members are compression members that are common in multiple areas of steel construction, which include cold-formed steel joints and stud walls. These members are vulnerable to unique buckling behaviors; however, limited experimental research has been done in this area. Give this gap, experimental testing of 71 built-up members was conducted in this study. The variations of the test specimens include multiple lengths, intermediate welds, orientations, and thicknesses. The experimental testing was devised to observe the different buckling modes of the built-up C-channels and the effects of the geometrical properties; to check for applicability of multiple intermediate welding patterns; and to evaluate both the 2001 and 2007 editions of the American Iron and Steel Institute (AISI) Specification for built-up members in pure compression. The AISI-2001 and AISI-2007 were found to give inconsistent results that at times were un-conservative or overly conservative in terms of axial strength. It was also found that orientation of the member has an important impact on the maximum failure load on the member.

고강도강 내진성능 향상부재를 적용한 건물 성능 비교 (Examination of Seismic Performance for Structure with Seismic Members made by High Strength Steel)

  • 김문정;하태욱;조석희
    • 한국강구조학회 논문집
    • /
    • 제27권3호
    • /
    • pp.281-288
    • /
    • 2015
  • 댐퍼를 비롯한 대부분의 내진성능 향상 부재는 골조를 구성하는 주요구조부재가 소성상태에 진입한 다음 나타나는 층 강성 저하에 대한 대처가 없어 대지진 시 건물의 층 파괴를 방지하지 못할 가능성이 높다. 이에 본 논문은 건물의 주요부재가 탄성항복한 뒤에도 건물의 층 강성을 일정기간 유지시킬 수 있는 고강도강 내진성능 향상부재를 제안한다. 본 논문에서는 다음과 같은 사실을 알 수 있다. (1) 골조의 소성화 항복 후 저감된 수평내력을 보강하는 탄성 부재를 제안방식으로 설계 시 기존 면적을 방해하지 않는 작은 단면으로 최대 층간변형각 0.02rad 까지 내력 저감 보강 가능 (2) 제안 내진성능 향상부재의 최저 적용으로도 설계 레벨을 상회하는 거대 지진에서 과다변형집중방지에 상당한 효과를 발휘하는 것을 확인.

강-콘크리트 합성 교량 바닥판의 피로거동에 대한 실험적 연구 (An Experimental Study on the Fatigue Behavior of Steel-Concrete Composite Bridge Deck)

  • 심정욱;김상효;정연주;박휘립
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.499-504
    • /
    • 2003
  • Future bridge decks must have high load-resistance capacity as well as fatigue strength to withstand the increase in traffic loading and the increase in span length between girders due to the decrease in the number of main girders. Steel-concrete composite bridge decks may be proper deck types to satisfy such requirements. To promote the application of composite bridge decks, a rational process to predict and evaluate the fatigue behavior of steel concrete composite bridge deck is required. Various types of steel-concrete composite bridge decks have been developed in many countries. In this study, combining advantages of the existing composite deck types, a new type of composite bridge deck is proposed. An experimental study is performed to examine the fatigue behavior of the proposed composite bridge deck. This composite bridge deck consists of corrugated steel sheet, welded T-beams, stud-type shear connectors and reinforced concrete filler. The fatigue tests are conducted under four-point bending test with three different stress ranges in constant amplitude. The fatigue category of the fillet welding between corrugated steel sheet and the T-beam is evaluated based on the S-N data obtained from the experiment.

  • PDF

Dynamic stiffness analysis of steel-concrete composite beams

  • Li, Jun;Huo, Qiji;Li, Xiaobin;Kong, Xiangshao;Wu, Weiguo
    • Steel and Composite Structures
    • /
    • 제16권6호
    • /
    • pp.577-593
    • /
    • 2014
  • An exact dynamic stiffness method is introduced for investigating the free vibration characteristics of the steel-concrete composite beams consisting of a reinforced concrete slab and a steel beam which are connected by using the stud connectors. The elementary beam theory is used to define the dynamic behaviors of the two beams and the relative transverse deformation of the connectors is included in the formulation. The dynamic stiffness matrix is formulated from the exact analytical solutions of the governing differential equations of the composite beams in undamped free vibration. The application of the derived dynamic stiffness matrix is illustrated to predict the natural frequencies and mode shapes of the steel-concrete composite beams with seven boundary conditions. The present results are compared to the available solutions in the literature whenever possible.

Ultimate strength behavior of steel plate-concrete composite slabs: An experimental and theoretical study

  • Wu, Lili;Wang, Hui;Lin, Zhibin
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.741-759
    • /
    • 2020
  • Steel plate-concrete composite slabs provide attractive features, such as more effective loading transfer, and more cost-effective stay-in-place forms, thereby enabling engineers to design more high-performance light structures. Although significant studies in the literatures have been directed toward designing and implementing the steel plate-concrete composite beams, there are limited data available for understanding of the composite slabs. To fill this gap, nine the composite slabs with different variables in this study were tested to unveil the impacts of the critical factors on the ultimate strength behavior. The key information of the findings included sample failure modes, crack pattern, and ultimate strength behavior of the composite slabs under either four-point or three-point loading. Test results showed that the failure modes varied from delamination to shear failures under different design factors. Particularly, the shear stud spacing and thicknesses of the concrete slabs significantly affected their ultimate load-carrying capacities. Moreover, an analytical model of the composite slabs was derived for determining their ultimate load-carrying capacity and was well verified by the experimental data. Further extensive parametric study using the proposed analytical methods was conducted for a more comprehensive investigation of those critical factors in their performance. These findings are expected to help engineers to better understand the structural behavior of the steel plate-concrete composite slabs and to ensure reliability of design and performance throughout their service life.