• Title/Summary/Keyword: Steel pipe

Search Result 1,031, Processing Time 0.026 seconds

Borehole magnetics for the estimation of unknown foundation pile depth (시추공자력계를 이용한 기초파일 근입심도 추정)

  • Jo, Churl-Hyun;Chung, Hyun-Key;Cho, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.2
    • /
    • pp.161-167
    • /
    • 1999
  • There is an increasing need for the estimation of foundation piles whose depths are unknown. Especially in repair and reinforcement works or in safety inspection and assessment to the big structures whose foundations are piles, the accurate information about the depth of foundation piles is one of the most important factors. A borehole magnetic tool has been developed and tested to meet this object. The fundamental base is that there usually exist many re-bars inside the foundation structure such as piles, and these re-bars are ferromagnetic materials which cause strong induced magnetic field comparable to the earth magnetic field. It utilizes flux-gate type magnetometer which measures 3-components of the magnetic field. Taking vertical derivatives of vertical component of the measured magnetic field, we can expect the error limit of estimating the depth of the pile end less than 20 cm in favorable condition. The maximum measurable distance is about 3 m to the pile from the borehole. The field data show that borehole magnetics is one of the most accurate, fast, and reliable methods for this object so far, as long as there is no magnetic materials such as deep located steel pipe or power cables close to the foundation piles.

  • PDF

Characteristics of Burst Pressure and Abrasion Resistance of Concrete Hose with Aramid Fiber Reinforcement and Rubber Composition (아라미드 섬유강화 및 고무조성에 따른 콘크리트 도킹호스의 파열압력과 내마모도 특성)

  • Kim, Yong-Hwan;Lee, Seung-Hwan;Sung, Il-Kyung;Lee, Yu-wool;Kang, Myungchang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.105-110
    • /
    • 2018
  • A concrete docking hose of pump car's boom pipe line have been used in many construction sites. They are long structures with continuous cornering, similar to a trunk of the elephant, characterized by a very high pressure resistance of 20MPa. They need flexible materials and structure in order to move the hose smoothy. But commercial concrete hose is hard to handle and heavy owing to adaption of steel reinforcement. In this study, it is tried an experimental approach to the characteristic of inner rubber layer and abrasion resistance. Also, we are investigated the bursting pressure according to the reinforcement of the hose and propose the usefulness of the hose reinforced with high strengthened aramid fiber.

Geometry impact on the stability behavior of cylindrical microstructures: Computer modeling and application for small-scale sport structures

  • Yunzhong Dai;Zhiyong Jiang;Kuan-yu Chen;Duquan Zuo;Mostafa habibi;H. Elhosiny Ali;Ibrahim Albaijan
    • Steel and Composite Structures
    • /
    • v.48 no.4
    • /
    • pp.443-459
    • /
    • 2023
  • This paper investigates the stability of a bi-directional functionally graded (BD-FG) cylindrical beam made of imperfect concrete, taking into account size-dependency and the effect of geometry on its stability behavior. Both buckling and dynamic behavior are analyzed using the modified coupled stress theory and the classical beam theory. The BD-FG structure is created by using porosity-dependent FG concrete, with changing porosity voids and material distributions along the pipe radius, as well as uniform and nonuniform radius functions that vary along the beam length. Energy principles are used to generate partial differential equations (PDE) for stability analysis, which are then solved numerically. This study sheds light on the complex behavior of BD-FG structures, and the results can be useful for the design of stable cylindrical microstructures.

A study on the digital signal processing by shear horizontal-electro magnetic acoustic transducer (SH-EMAT에 의한 Digital 신호처리에 관한 연구)

  • Kim, Jae-Yeol;Park, Hwn-Kyu;Cho, Young-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.32-40
    • /
    • 1994
  • In this study by using EMAT(electro magnetic acoustic transducer)the artificial slit is installed on 12B-SUS pipe test piece. By making 4 cycle SH-burst (EMA) incidence to 45 .deg. angle, the signal data of pulse, received from EMAT are translated into digital-signal-processing- method SSP(Split Spectrum Processing) and Deconvolution method. The main conclusions obtained are as follows; (1) the signal data received from EMAT are translated with digital signal proc- essing of SSP-method and Deconvolution-method and this method shows exellent results more than Ultrasonic testing method does; (2) noise can well be removed by SSP with signal data, and resolution and S/N ratio are advanced; (3) when used with Ultrasonic wave general stainless steel has proporties of multiscattering and reflection phenomena, but resolution is progressed by using Deconvolution method;and (4) as addition-averaging-processing mumber is increasing, the resolution and S/N ratio are improved and the satisfactory signal is obtained.

  • PDF

A Study on Structural Safety Management Plan for Above Ground and Underground Structure Dismantling work (지상 및 지하구조물 해체공사를 위한 구조 안전관리 방안 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.194-195
    • /
    • 2021
  • Due to urban regeneration projects or changes in the living environment, there is an increasing need to demolish old buildings that have lost their functions. Demolition of above ground and underground structures is an important construction project that greatly affects the construction period and safety of the entire process. However, it is difficult for the safety officer to manage the demolition work due to the lack of specific and diverse data applicable to the site of the demolition plan. Therefore, in this study, items that need to be improved in structural safety when the above-ground and underground structures are demolished are reviewed and organized. For the main contents of structural safety management in demolition work, 1) structural review reflecting the order of demolition work, 2) installation and dismantling of steel pipe scaffolding and dust nets, 3) installation and dismantling of system scaffolding, 4) installation and dismantling of fall prevention nets, 5) jack support Installation and dismantling, 6) movement of equipment, movement and planning between floors, 7) equipment for demolition of structures, height of remnants, 8) site cleanup, and 9) equipment operators were categorized and arranged.

  • PDF

Uncertainty Quantification of Welding Residual Stress Analysis based on Domestic Organizations Round-Robin Evaluation (라운드로빈 평가 결과에 기반한 국내 기관의 용접잔류응력 해석 분포의 불확실성 평가)

  • Sung-Kyun Jung;Jun-Young Jeon;Chan-kyu Kim;Chang-Sik Oh;Sung-Sik Kang;Chang-Young Oh
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.2
    • /
    • pp.130-139
    • /
    • 2023
  • This paper examines the quantification of uncertainty for welding residual stresses in dissimilar metal welds used in nuclear power plants. A mock-up of a dissimilar metal weld pipe, consisting of carbon and stainless steel pipes, was fabricated to measure the residual stress. A Round-Robin analysis was conducted by Korean institutions to assess the welding residual stress. The analysis was carried out in the second order, and the data obtained by each institution was evaluated based on the information provided. Using the Round-Robin results, the distribution of uncertainty in welding residual stresses among Korean institutions was evaluated. The quantification of uncertainty for Korean institutions was found to have a wider range compared to the distribution of welding residual stresses observed in overseas institutions. This study is considered useful in the establishment of comprehensive strategies for evaluating welding residual stress analysis methods used by domestic institutions.

EVA Sheet and Butyl Rubber based Waterproofing·Anti-Corrosion Sheet for Corrosion Maintenance and Repairing in the Interior Side of the Large Steel Pipes in Water Treatment Facilities (상수도용 대구경 녹 발생 강관 내부의 보수 및 성능 유지를 위한 EVA 시트와 부틸고무를 합지한 자착식 방수방식 시트의 부착성능 평가)

  • An, Ki-Won;Kim, Byoung-Il;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.267-274
    • /
    • 2017
  • This study discusses the applicability of environmental friendly EVA based butyl rubber self-adhesive waterproof sheet designed to prevent corrosion of large scale pipes used in the water treatment facilities during th water treatment process. The experiments conducted tested the waterproofing sheet's adhesion strength on the steel surface of the pipes and checked for whether the material has the proper response properties against the various environmental conditions. In addition, it the sheet adhered to the steel pipe was to see if the adhesion hold against the water pressure due to the ingress of inflow water. Finally, the waterproofing sheet's adhesion strength was tested on a rusted steel surface to confirm whether the material has the necessary properties to secure stable adhesion strength and prevent corrosion of steel pipes at the same time during the process of installation or maintenance. As a result, the self-adhesive waterproof sheets showed that all attachments in the untreated, long term pressuring, immersion in chemical substance (hydrochloric acid, hypochlorous acid, sodium hydroxide), low temperature ($-20^{\circ}C$) conditions showed a adhesion performance of higher than 1.5N/mm, which is the performance standard of KS F 4934. Also, in the testing to check for the adhesion property against inverse water pressure, it was observed that the adhesion failure did not occur even up to $3.0N/mm^2$ pressure. Also, in the process of assessing the adhesion performance on rusted steel surface, specimens after 12 hours of corrosion treatment was shown to have 2.1N/mm, and specimens after 168 hours of corrosion treatment was shown to have 2.0N/mm adhesion strength performance.

Correlation of Microstructure with Mechanical Properties by Welding Conditions of Electric Resistance Welding(ERW) (전기저항용접(ERW)조건에 따른 미세조직과 기계적 특성의 연관성)

  • Lee, Kyung-Min;Lee, Dong-Eon;Kim, Sung-Woong;Yoon, Byung-Hyun;Kang, Hee-Jae;Kang, Nam-Hyun
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.27-27
    • /
    • 2010
  • 청정에너지원의 수요가 증가함에 따라 에너지원의 공급로의 역할을 하는 강관의 수요가 증가하고 있다. 소재가공 기술의 발전과 함께 경량의 고장력 강재의 적용은 공급로의 역할을 하는 강관의 비용절감 및 자원의 효율적 이용 측면에서 지속적으로 연구 개발을 이어왔다. 이러한 추세에 따라 구조용 또는 라인파이프용 강관에서도 고장력 강재의 적용과 함께 고인성 그리고 용접성의 향상을 위한 다양한 라인파이프용 강재의 개발과 이의 적용이 그간 활발히 진행되어왔다. 용도상 반드시 필요한 특성인 고장력, 고인성, 용접성 등 외에도 다양한 강재의 사용에 따른 제조공정상 즉 용접공정에서 발생될 수 있는 용접부의 기계적 특성 변화에 대한 특성 연구 및 기술 연구가 계속 되어왔다. 주로 강관을 생산하는데 쓰이는 ERW (Electric Resistance Welding) 공정에서도 이러한 문제점을 해결하기 위해 많은 연구가 진행되고 있다. ERW는 높은 생산성과 낮은 제조비용의 장점을 가지고 있으나 용접 후 용접부의 기계적 특성 감소로 인한 단점이 있다. 때문에 기계적 특성향상을 위해 최적의 용접조건에 대해 연구해야 할 필요가 있다. 본 연구에서는 4가지 합금강관의 ERW 용접시 용접 입열량의 변화와 용접부의 후열처리를 통한 미세조직의 변화와 기계적 특성에 대해서 고찰하였다. 4강종 시편의 미세조직을 OM, SEM을 통한 분석 이후 인장시험 및 경도시험 등을 통해 기계적 특성을 평가하였다. 대부분의 시편에서 입열량의 증가에 따라 Ferrite 분율이 증가하였고 용접중앙부의 Ferrite 양이 용접경계부 보다 많았다. Ferrite 집중부의 분포가 극명하게 관찰되었던 DP780 (적정) 강종과 미세하게나마 Ferrite 집중부가 존재하였던 K55 (과소, 과대) 강종에서 나란히 경도 하락 현상이 관찰되었다. 이는 강종마다 고유의 Ceq, 합금 중 Mn 농도, 입열량 등에 의한 복합적인 이유 때문으로 판단된다. 탄소가 0.3~0.4 wt% 함유된 중탄소강인 S45C, K55의 경우 용접중앙부와 용접경계부의 페라이트 분율 차이가 큰 것을 알 수 있었다. 이는 용접시 열에 의한 탈탄현상으로 인해 나타나는 현상으로 판단된다.

  • PDF

Development of Structural Model and Analysis of Design Factors for Small Greenhouse of Urban Agriculture (도시농업을 위한 소형온실 설계요인 분석 및 구조모델 개발)

  • Kim, Hyung-Kweon;Ryou, Young-Sun;Kim, Young-Hwa;Lee, Tae-Seok;Oh, Sung-Sik;Lee, Won-Suk;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.388-395
    • /
    • 2019
  • The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.

Design on the large section of station tunnel under shallow overburden (저토피고 대단면 정거장터널의 설계)

  • Jeong, Yun-Young;Choi, Hae-Joon;Kim, Byung-Ju;Yu, Bong-Won;Kim, Yong-Il;Oh, Sung-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.2
    • /
    • pp.171-182
    • /
    • 2007
  • For minimizing the effect on the focus of civil traffic and environment conditions related to the excavation at the traffic jamming points, an underground station tunnel was planned with 35.5 m in length and bigger area than $200\;m^2$ in sedimentary rock mass. It faced the case that the overburden was just under 13 m. Not based on a pattern design but on the case histories of similar projects and arching effect, the design of large section tunnel under shallow overburden was investigated on three design subjects which are shape effect on the section area, application method of support pressure, and supporting and tunnel safety. According to the mechanical effect from section shape, a basic design and a preliminary design was obtained, and then supporting method of large section was planned by the supporting of NATM and a pipe roof method for subsidence prevention and mechanical stability. From the comparative study between both designs, it was found that the basic design was suitable and acceptable for the steel alignment of tunnel lining, safety and the design parameter restricted by the limit considered as partition of the excavation facilities. Through the analysis result of preliminary design showing the mechanical stability without stress concentration in tunnel arch level, it also was induced that shape effect of the large section area and yielding load obtained from deformation zone in the surrounding rock mass of tunnel have to be considered as major topics for the further development of design technique on the large section tunnel.

  • PDF