• 제목/요약/키워드: Steel cable

검색결과 304건 처리시간 0.037초

Wind-resistant performance of cable-supported bridges using carbon fiber reinforced polymer cables

  • Zhang, Xin-Jun;Ying, Lei-Dong
    • Wind and Structures
    • /
    • 제10권2호
    • /
    • pp.121-133
    • /
    • 2007
  • To gain understanding of the applicability of carbon fiber reinforced polymer (CFRP) cable in cable-supported bridges, based on the Runyang Bridge and Jinsha Bridge, a suspension bridge using CFRP cables and a cable-stayed bridge using CFRP stay cables are schemed, in which the cable's cross-sectional area is determined by the principle of equivalent axial stiffness. Numerical investigations on the dynamic behavior, aerostatic and aerodynamic stability of the two bridges are conducted by 3D nonlinear analysis, and the effect of different cable materials on the wind resistance is discussed. The results show that as CFRP cables are used in cable-supported bridges, (1) structural natural frequencies are all increased, and particularly great increase of the torsional frequency occurs for suspension bridges; (2) under the static wind action, structural deformation is increased, however its aerostatic stability is basically remained the same as that of the case with steel cables; (3) for suspension bridge, its aerodynamic stability is superior to that of the case with steel cables, but for cable-stayed bridge, it is basically the same as that of the case with steel stay cables. Therefore as far as the wind resistance is considered, the use of CFRP cables in cable-supported bridges is feasible, and the cable's cross-sectional area should be determined by the principle of equivalent axial stiffness.

케이블 단선 후 강사장교의 구조 및 극한 거동 변화 (Change of Statical Behavior and Ultimate Capacity of Steel Cable-stayed Bridges after Cable Failure)

  • 김승준;최준호;원덕희;한택희;강영종
    • 한국강구조학회 논문집
    • /
    • 제23권6호
    • /
    • pp.747-761
    • /
    • 2011
  • 본 논문에서는 강사장교의 케이블이 단선된 후 정역학적인 구조 거동 및 극한 거동 변화에 대해 기술한다. 사장교의 케이블은 화재, 차량의 충돌, 케이블 본선 및 정착구의 피로에 의해 단선이 가능하다. 이에 더하여 필요시 케이블의 교체 작업 시 일시적인 단선이 나타날 수 있다. 케이블이 구조물 본체에서 단락되면 결과적으로 케이블이 분담해야할 힘을 지지하지 못하여 이 힘은 다른 구조체로 전달되고 결과적으로 구조 상태의 변화가 발생한다. 그리고 케이블의 단선은 결국 구조물의 지지력의 손실을 의미하므로 케이블 단선 후 구조물의 내하력이 저하될 것이다. 본 연구에서는 엄밀한 비선형 유한요소해석 이론을 근간으로 하여 케이블 단선 후 구조물의 새로운 평형상태를 찾는 단선 해석기법을 제시한다. 그리고 케이블이 단선된 후 활하중에 대한 구조물의 극한거동을 해석할 수 있는 극한 해석 기법 역시 제시한다. 보다 합리적인 해석 연구를 위해 본 연구에서는 초기형상해석, 케이블 단선해석, 활하중에 대한 비선형해석을 순차적으로 수행하는 총 세단계의 해석 절차를 거친다. 본 해석기법을 이용하여 각 케이블의 단선이 사장교의 구조 상태 및 극한 거동의 변화에 미치는 영향을 분석하였다.

다양한 케이블 요소를 이용한 강사장교의 극한강도 평가 (Evaluation of Limit Strength for Steel Cable-Stayed Bridgesusing Various Cable Elements)

  • 송원근;이종우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.115-121
    • /
    • 2006
  • 본 논문에서는 다양한 형태의 케이블 요소들의 거동이 강사장교의 극한강도에 미치는 영향을 검토하였다. 연화소성힌지 모델을 사용한 극한강도 평가 시 보-기둥 부재의 기하학적 비선형은 안정함수를 사용하여 고려하였고 재료적 비선형성을 반영하기 위하여 CRC 접선계수와 포물선 함수를 사용하였다. 케이블 부재는 새그의 영향이 고려되었다. 연구 결과 등가탄성계수가 반영된 등가트러스 요소를 사용한 경우 강사장교의 극한강도가 케이블 요소 또는 현수선 요소를 사용하여 평가한 극한강도 보다 안전측으로 평가되었다.

Structural behavior of non-symmetrical steel cable-stayed bridges

  • Jorquera-Lucerga, Juan J.;Lozano-Galant, Jose A.;Turmo, Jose
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.447-468
    • /
    • 2016
  • Despite of the growing number of built examples, the analysis of non-symmetrical cable-stayed bridges has not received considerable attention from the researchers. In fact, the effects of the main design parameters in the structural behavior of these bridges are not addressed in detail in the literature. To fill this gap, this paper studies the structural response of a number of non-symmetrical cable-stayed bridges. With this aim, a parametric analysis is performed to evaluate the effect of each of the main design parameters (the ratio between the main and the back span length, the pylon, the deck and backstay stiffnesses, the pylon inclination, and the stay configuration) of this kind of bridges. Furthermore, the role of the geometrical nonlinearity and the steel consumption in stays are evaluated.

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

Stability analysis of steel cable-stayed bridges

  • Tang, Chia-Chih;Shu, Hung-Shan;Wang, Yang-Cheng
    • Structural Engineering and Mechanics
    • /
    • 제11권1호
    • /
    • pp.35-48
    • /
    • 2001
  • The objective of this study is to investigate the stability behavior of steel cable-stayed bridges by comparing the buckling loads obtained by means of finite element methods with eigen-solver. In recent days, cable-stayed bridges dramatically attract engineers' attention due to their structural characteristics and aesthetics. They require a number of design parameters and present a high degree of static indetermination, especially for long span bridges. Cable-stayed bridges exhibit several nonlinear behaviors concurrently under normal design loads due to the individual nonlinearity of substructures such as the pylons, stay cables, and bridge deck, and their interactions. The geometric nonlinearities arise mainly from large displacements of cables. Strong axial and lateral forces acting on the bridge deck and pylons cause structural nonlinear behaviors. The interaction is among the substructures. In this paper, a typical three-span steel cable-stayed bridge with a variety of design parameters has been investigated. The numerical results indicate that the design parameters such as the ratio of $L_1/L$ and $I_p/I_b$ are important for the structural behavior, where $L_1$ is the main span length, L is the total span length of the bridge, $I_p$ is the moment of inertia of the pylon, and $I_b$ is the moment of inertia of the bridge deck. When the ratio $I_p/I_b$ increases, the critical load decreases due to the lack of interaction among substructures. Cable arrangements and the height of pylon are another important factors for this type of bridge in buckling analysis. According to numerical results, the bridges supported by a pylon with harp-type cable arrangement have higher critical loads than the bridges supported by a pylon with fan-type cable arrangement. On contrary, the shape of the pylon does not significantly affect the critical load of this type of bridge. All numerical results have been non-dimensionalized and presented in both tabular and graphical forms.

케이블 장력변화가 강철도 복합교량 상 자갈궤도의 궤도틀림에 미치는 영향 (Effect of Cable Tension Changes on Track Irregularity of Railway Ballasted Track on Railway Steel Composite Bridge)

  • 최정열;이수재
    • 문화기술의 융합
    • /
    • 제9권4호
    • /
    • pp.633-638
    • /
    • 2023
  • 본 연구에서는 공용중인 강철도 복합교량의 케이블 장력변화가 철도교량 상 자갈궤도의 궤도틀림에 미치는 영향을 해석적으로 분석하였다. 케이블 장력에 대한 설계 및 해석결과 비교 결과, 약 3% 미만의 차이가 나타나 해석모델링은 설계조건을 잘 반영하는 것으로 분석되었다. 또한 현장측정결과와 해석 케이블 장력과 비교하여 해석모델링의 적정성을 입증하였다. 케이블 장력 변화를 변수로 설정하여 강철도 복합교량의 궤도틀림을 해석적으로 분석하였다. 분석결과, 전체 및 편측 케이블 장력변화는 궤도틀림 항목 중 고저틀림에 직접적인 영향을 미치는 것으로 분석되었다. 또한 케이블 위치와 근접한 구간에서 궤도틀림의 변화가 발생하는 것으로 나타났다. 케이블 장력 변화는 수평방향에 의한 궤도틀림(방향틀림 및 궤간틀림)보다는 연직방향과 직접적인 상관성을 갖는 궤도틀림(고저틀림 및 수평틀림)에 보다 직접적인 영향을 미치는 것으로 분석되었다.

π형 주형을 가진 강합성 사장교의 공기역학적 제진방법에 대한 실험적 연구 (An Experimental Study on Wind Aerodynamic Improvement of Steel Composite Cable Stayed Bridge having π-shaped Girder)

  • 장동일;민인기
    • 한국강구조학회 논문집
    • /
    • 제10권4호통권37호
    • /
    • pp.801-811
    • /
    • 1998
  • 본 논문은 풍동실험을 통하여 ${\pi}$형단면을 가지는 강합성사장교의 공기역학적 특성과 제진방법에 대한 연구이다. 제진장치로는 Fairing, Extension, Post, Flap 등이 사용되었고, 가장 효과적인 개선단면을 선정하여 영각, 감쇠비와 난류실험을 수행하여 내풍안정성을 평가하였다. 실험결과 선정된 개선단면에서 공기역학적 내풍안정성이 향상되었고 공기역학적특성이 규명되었다. 따라서 본 연구에서 수행된 ${\pi}$형단면은 내풍설계의 기초 자료로 활용될 수 있을 것이다.

  • PDF

완성계 강사장교의 극한 거동의 해석적 연구 (Analytical Study of Ultimate Behavior of Steel Cable-stayed Bridges)

  • 김승준;임석빈;이기세;강영종
    • 대한토목학회논문집
    • /
    • 제32권2A호
    • /
    • pp.85-95
    • /
    • 2012
  • 본 논문은 비선형 해석을 통한 완성계 강사장교의 극한 거동에 대해 다룬다. 사장교는 재료적 비선형성과 함께 다양한 기하학적 비선형성을 나타내므로 극한 거동을 명확히 규명하려면 반드시 합리적인 비선형해석이 수행되어야 한다. 따라서 본 연구에서는 합리적인 극한 해석기법을 통해 활하중에 대한 강사장교의 주요한 극한거동을 규명하고자 하였다. 강사장교의 비선형 해석을 위하여 비선형 트러스 요소 및 비선형 프레임 요소를 이용하였고, 강재의 재료적 비선형성을 효율적으로 고려하기 위해 개선소성힌지법을 이용하였다. 활하중에 대한 극한 거동을 합리적으로 분석하기 위해 본 연구에서는 초기형상해석-활하중 해석으로 이어지는 2단계 해석기법을 통해 극한 해석을 수행하였다. 해석 모델은 총 지간장이 920.0 m 사장교를 이용하였고, 방사형 및 팬 형 사장교를 해석에 이용하였다. 극한해석결과를 통해 얻은 하중-변위 곡선, 구조물 변형형상, 소성단면, 휨모멘트분포도 등을 분석하여 활하중에 대한 완성계 사장교의 주요한 극한 거동을 규명하였다.

144심용 초다심 SSLT OPGW 개발 (Development of Stainless Steel Loose Tube Optical Ground Wire with 144 Single Mode Fibers)

  • 백승엽;김경민;김성욱;김도운;이인호;손광익;이승찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.395-398
    • /
    • 2001
  • Recently, the increasing need for internet and the activation of hiring business of communication line makes the demand for OPGW cable which can construct the optical communication network in the basis of existing overhead power transmission line. Especially, the demand is focused on the high fiber count OPGW due to high capacity transmission. In step with the trend toward high fiber count cable we have developed the Stainless Steel Loose Tube type OPGW within which have 144core firstly in KOREA. This paper describes the cable design and manufacturing process which gives the stable operation in very severe conditions and the long-term reliability test results conducted in according to dominant specification IEEE Std. 1138-1194.

  • PDF