• 제목/요약/키워드: Steel Hysteretic damping device

검색결과 10건 처리시간 0.028초

고무코어패드와 강재이력감쇠장치를 결합한 복합감쇠장치의 이력특성에 관한 연구 (A Study on Characteristics of Hybrid Damping Device Combining Rubber Core Pad and Hysteretic Steel Slit)

  • 박병태;이준호
    • 한국공간구조학회논문집
    • /
    • 제23권1호
    • /
    • pp.45-52
    • /
    • 2023
  • This study proposes an RCS composite damping device that can achieve seismic reinforcement of existing buildings by dissipating energy by inelastic deformation. A series of experiments assessing the performances of the rubber core pad, hysteretic steel slit damping device, and hybrid RCS damping device were conducted. The results showed that the ratios of the deviations to the mean values satisfied the domestic damping-device conformity condition for the load at maximum device displacement in each direction, at the maximum force and minimum force at zero displacement, as well as the hysteresis curve area. In addition, three analysis models based on load-displacement characteristics were proposed for application to seismic reinforcement design. In addition, the validity of the three proposed models was confirmed, as they simulated the experimental results well. Meanwhile, as the shear deformation of the rubber-core pad increased, the hysteretic behavior of super-elasticity greatly increased the horizontal force of the damping device. Therefore, limiting the allowable displacement during design is deemed to be necessary.

고감쇠고무와 강재슬릿이 결합된 하이브리드 댐퍼의 실험적 구조성능평가 (Experimental Structural Performance Evaluation of Hybrid Damper Combining with High Damping Rubber and Steel Slit)

  • 이준호;박병태;김유성
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.23-30
    • /
    • 2022
  • It is effective to apply hybrid damping device that combine separate damping device to cope with various seismic load. In this study, HRS hybrid damper(hybrid rubber slit damper) in which high damping rubber and steel slit plate are combined in parallel was proposed and structural performance tests were performed to review the suitability for seismic performance. Cyclic Loading tests were performed in accordance with criteria presented in KDS 41 17 00 and MOE 2019. As a result of the test, the criteria of KDS 41 17 00 and MOE2019 was satisfied, and the amount of energy dissipation increased due to the shear deformation of the high-damping rubber at low displacement. Result of performing the RC frame test, the allowable story drift ratio was satisfied, and the amount of energy dissipation increased in the reinforced specimen compared to the non-reinforced specimen.

슬릿형 강재이력 감쇠장치의 성능평가를 위한 실험연구 (An Experimental Study on Performance Evaluation of Hysteretic Steel Slit Damper)

  • 최기선;이현지;김민선;유영찬
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.33-39
    • /
    • 2018
  • This study performed experimental validation of the hysteretic steel slit damper's basic and dependent characteristics, which should be considered for the design. The basic characteristic of the steel slit damper is used for determining design properties of non-linear analysis, such as yielding strength, yielding displacement, elastic stiffness and post-yielding stiffness. In order to evaluate dependent characteristics of the hysteretic steel slit damper, repeated deformation capacity with respect to the displacement, velocity and aspect ratio of the damper was evaluated. In this study, steel slit damper, which is widely used in Korea, was considered. The slit dampers with 55kN and 240kN of yielding strength were produced and tested. It was concluded that the slit damper's hysteresis behavior was affected by the dependent characteristics: displacement, velocity and aspect ratio. In other words, the steel slit damper's behavior was stable within limit displacement, and aspect ratio of the strut affected repeated deformation capacity of the damper subjected to large deformation. In addition, it was observed that the repeated deformation capacity abruptly decreased at the high speed range (${\geq}60mm/sec$). Furthermore, the experimental results were evaluated with the criterion of the damping device specified in ASCE7-10.

Steel hexagonal damper-brace system for efficient seismic protection of structures

  • Mohammad Mahdi, Javidan;Jinkoo, Kim
    • Steel and Composite Structures
    • /
    • 제45권5호
    • /
    • pp.683-695
    • /
    • 2022
  • Conventional braces are often used to provide stiffness to structures; however due to buckling they cannot be used as seismic energy dissipating elements. In this study, a seismic energy dissipation device is proposed which is comprised of a bracing member and a steel hysteretic damper made of steel hexagonal plates. The hexagonal shaped designated fuse causes formation of plastic hinges under axial deformation of the brace. The main advantages of this damper compared to conventional metallic dampers and buckling-restrained braces are the stable and controlled energy dissipation capability with ease of manufacture. The mechanical behavior of the damper is formulated first and a design procedure is provided. Next, the theoretical formulation and the efficiency of the damper are verified using finite element (FE) analyses. An analytical model of the damper is established and its efficiency is further investigated by applying it to seismic retrofit of a case study structure. The seismic performance of the structure is evaluated before and after retrofit in terms of maximum interstory drift ratio, top story displacement, residual displacement, and energy dissipation of dampers. Overall, the median of maximum interstory drift ratios is reduced from 3.8% to 1.6% and the residual displacement decreased in the x-direction which corresponds to the predominant mode shape of the structure. The analysis results show that the developed damper can provide cost-effective seismic protection of structures.

An innovative BRB with viscoelastic layers: performance evaluation and numerical simulation

  • Zhou, Ying;Gong, Shunming;Hu, Qing;Wu, Rili
    • Structural Monitoring and Maintenance
    • /
    • 제5권2호
    • /
    • pp.205-229
    • /
    • 2018
  • Energy induced by minor earthquake and micro vibration cannot be dissipated by traditional buckling-restrained braces (BRBs). To solve this problem, a new type of hybrid passive control device, named as VE-BRB, which is configured by a BRB with high-damping viscoelastic (VE) layers, is developed and studied. Theoretical analysis, performance tests, numerical simulation and case analysis are conducted to study the seismic behavior of VE-BRBs. The results indicate that the combination of hysteretic and damping devices lead to a multi-phased nature and good performance. VE-BRB's working state can be divided into three phases: before yielding of the steel core, VE layers provide sufficient damping ratio to mitigate minor vibrations; after yielding of the steel core, the steel's hysteretic deformations provide supplemental dissipative capacity for structures; after rupture of the steel core, VE layers are still able to work normally and provide multiple security assurance for structures. The simulation results agreed well with the experimental results, validating the finite element analysis method, constitutive models and the identified parameters. The comparison of the time history analysis on a 6-story frame with VE-BRBs and BRBs verified the advantages of VE-BRB for seismic protection of structures compared with traditional BRB. In general, VE-BRB had the potential to provide better control effect on structural displacement and shear in all stages than BRB as expected.

고감쇠고무와 강재슬릿의 복합 댐퍼로 보강한 건축물의 해석적 성능평가 (Analytical Performance Evaluation of Structure Reinforced with HRS Damper)

  • 김유성;이준호
    • 한국공간구조학회논문집
    • /
    • 제22권4호
    • /
    • pp.31-38
    • /
    • 2022
  • In this study, an incremental loading test of the HRS(Hybrid Rubber Slit) damper was additionally performed to define the physical characteristics according to the incremental test results, and an analytical study was performed according to the damping design procedure by selecting an example structure. As a result of performing seismic performance evaluation before reinforcement by selecting a RC structure similar to an actual school structure as an example structure, the story drift ratio was satisfied, but some column members collapsed due to bending deformation. In order to secure the seismic performance, the damping design procedure of the HRS damper was presented and performed. As a result of calculating the amount of damping device according to the expected damping ratio and applying it to the example structure, the hysteresis behavior was stable without decrease in strength, and the story drift ratio and the shear force were reduced according to the damping effect. Finally the column members that had collapsed before reinforcement satisfied the LS Level.

Distribution of Optimum Yield-Strength and Plastic Strain Energy Prediction of Hysteretic Dampers in Coupled Shear Wall Buildings

  • Bagheri, Bahador;Oh, Sang-Hoon;Shin, Seung-Hoon
    • 국제강구조저널
    • /
    • 제18권4호
    • /
    • pp.1107-1124
    • /
    • 2018
  • The structural behavior of reinforced concrete coupled shear wall structures is greatly influenced by the behavior of their coupling beams. This paper presents a process of the seismic analysis of reinforced concrete coupled shear wall-frame system linked by hysteretic dampers at each floor. The hysteretic dampers are located at the middle portion of the linked beams which most of the inelastic damage would be concentrated. This study concerned particularly with wall-frame structures that do not twist. The proposed method, which is based on the energy equilibrium method, offers an important design method by the result of increasing energy dissipation capacity and reducing damage to the wall's base. The optimum distribution of yield shear force coefficients is to evenly distribute the damage at dampers over the structural height based on the cumulative plastic deformation ratio of the dissipation device. Nonlinear dynamic analysis indicates that, with a proper set of damping parameters, the wall's dynamic responses can be well controlled. Finally, based on the total plastic strain energy and its trend through the height of the buildings, a prediction equation is suggested.

복합 슬릿-마찰 감쇠장치가 적용된 철근 콘크리트 특수 모멘트 저항골조의 내진성능 평가 (Seismic Performance Evaluation of Special Reinforced Concrete Moment Resisting Frames With Hybrid Slit-Friction Damper)

  • 이준호;김기철;김진구
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.35-42
    • /
    • 2017
  • This study develops a new hybrid passive energy dissipation device for seismic rehabilitation of an existing structure. The device is composed of a friction damper combined with a steel plate with vertical slits as a hysteretic damper. Analytical model is developed for the device, and the capacity of the hybrid device to satisfy a given target performance is determined based on the ASCE/SEI 7-10 process. The effect of the device is verified by nonlinear dynamic analyses using seven earthquake records. The analysis results show that the dissipated inelastic energy is concentrated on the hybrid damper and the maximum interstory drift of the SMRF with damping system satisfies the requirement of the current code.

콘크리트에 매립된 카고메 감쇠시스템의 내진거동평가 (Seismic Behavior Evaluation of Embedded Kagome Damping Device)

  • 허무원;이상현;김종호;황재승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권2호
    • /
    • pp.84-91
    • /
    • 2019
  • 최근 들어 우리나라에서도 설치와 유지관리가 용이하며 경제성이 뛰어난 강재이력형 감쇠장치를 적용하여 내진성능을 확보하고자 하는 건물들이 다수 건설되고 있다. 하지만 이러한 강재이력형 감쇠장치가 철근콘크리트 건물에 적용되는 경우 감쇠장치를 설치하기 위한 연결구조물은 전체적인 시스템을 복잡하게 만들어 감쇠장치의 신뢰도를 저하시키는 요소가 되기도 한다. 이에 본 연구에서는 기존연구에서 개발된 카고메 감쇠장치를 대상으로 별도의 연결구조 없이 철근콘크리트 지지구조물에 감쇠장치를 직접 매립할 수 있는 시스템을 제안하고자 하며, 매립길이에 따른 내진거동을 확인하여 동 시스템의 정립을 위한 기초자료를 제공하고자 한다. 실험결과, $1.0l_d$ 매립길이 실험체의 경우 카고메 감쇠장치 매립부분에서 콘 파괴와 유사한 형태의 뽑힘이 발생하였다. 반면, $2.0l_d$ 매립길이를 확보한 실험체는 실험 종료 시까지 뽑힘 및 콘 파괴 없이 안정적인 이력거동을 나타내었고 $1.0l_d$ 매립길이 대비 $2.0l_d$ 매립길이가 약 1.3배의 향상된 에너지소산능력을 나타내었다. 본 연구에서 제안하는 시스템을 적용할 경우, 기존 설치방법 변경에 따른 기타 철물 제작 비용을 줄일 수 있으며, 시공 시에도 부수적인 철물 시공을 줄여 공기를 단축할 수 있다.

건물의 내진보강을 위한 캔틸레버타입 강재댐퍼의 실험 (Experimental study on a Cantilever Type Metallic Damper for Seismic Retrofit of Building Structures)

  • 안태상;김영주;박진화;김형근;장동운;오상훈
    • 한국강구조학회 논문집
    • /
    • 제24권2호
    • /
    • pp.149-161
    • /
    • 2012
  • 최근에 신축 건물이나 기존 건물의 내진보강을 위해서 수동제진장치의 일종인 에너지소산형 제진장치의 사용이 매우 증가하고 있다. 제진장치는 선진국을 중심으로 개발되어 왔고 제한적으로 사용해 오고 있었지만, 최근에는 다소 저렴한 장치개발을 통하여 강진지역의 개발도상국으로도 그 사용이 확대되고 있다. 본 연구는 기존 또는 신축 건물의 내진보강을 위한 캔틸레버타입 강재댐퍼를 개발하고 제안하였다. 댐퍼에 대한 반복가력 실험을 바탕으로 이력거동 및 에너지소산능력을 조사하였다. 실험결과는 제진장치가 안정된 이력특성을 나타내고 있으며 큰 에너지소산능력을 갖고 있음을 보여준다. 실험결과를 바탕으로 댐퍼에 대한 간단한 하중-변위 이력모델을 제안하였다.