• 제목/요약/키워드: Steel Beam

검색결과 3,058건 처리시간 0.024초

훅트강섬유보강철근콘크리트보의 휨거동에 관한 실험적 연구 (Experimental Study on the Flexural Behavior of Reinforced Hooked Steel Fibrous Concrete Beam)

  • 심종성;이차돈;김규선;오홍섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.311-318
    • /
    • 1995
  • Increases in strength and ductilities of steel fiber reinforced concrete(SFRC) under direct tension and compression result in improvements of flexural behavior of reinforced steel fibrous concrete beam(RSFCB) Use of hooked steel fibers in stead of round steel fibers enhances futher the structural porperties of a beam due to their greater mechanical bond resistance compared to that of round steel fibers. Flexural strength, initial stiffness ductility and failure mechani는 of RSFCB are dependent upon material and structural parameters and among which are the volume fraction of fibers, reinforcement ratio, and casting depth of SFRC in a beam section. The flexural behavior of RSFCB's are examined experimentally in this study and some conclusions are made regarding those effects of main material and structural parameters on the overall behavior of RSFCB.

  • PDF

집속 이온빔과 디지털 화상 관련법을 이용한 고 탄소 미세 강선의 잔류 응력 측정 (Measurement of the Residual Stress in the Steel Wires by using Focused Ion Beam and Digital Image Correlation Method)

  • 양요셉;배종구;박찬경
    • 소성∙가공
    • /
    • 제16권4호
    • /
    • pp.323-328
    • /
    • 2007
  • The residual stress in axial direction of the steel wires has been measured by using a method based on the combination of the focused ion beam(FIB) milling and digital image correlation(DIC) program. The residual stress is calculated from the measured displacement field before and after the introduction of a slot along the steel wires. The displacement is obtained by the digital correlation analysis of high-resolution scanning electron micrographs, while the slot is introduced by FIB milling with low energy beam. The experimental procedures are described and the feasibilities are demonstrated in steel wires fabricated with different conditions. It reveals that the tensile residual stress is formed in all steel wires and this is strongly influenced by the fabrication conditions.

Cyclic tests on bolted steel and composite double-sided beam-to-column joints

  • Dubina, Dan;Ciutina, Adrian Liviu;Stratan, Aurel
    • Steel and Composite Structures
    • /
    • 제2권2호
    • /
    • pp.147-160
    • /
    • 2002
  • This paper summarises results of the research performed at the Department of Steel Structures and Structural Mechanics from the "Politehnica" University of Timisoara, Romania, in order to evaluate the performance of beam-to-column extended end plate connections for steel and composite joints. It comprises laboratory tests on steel and composite joints, and numerical modelling of joints, based on tests. Tested joints are double-sided, with structural elements realised of welded steel sections. The columns are of cruciform cross-section, while the beams are of I section. Both monotonic and cyclic loading, symmetrically and antisymmetrically, has been applied. On the basis of tested joints, a refined computer model has been calibrated using a special connection element of the computer code DRAIN 2DX. In this way, a static/dynamic structural analysis of framed structures with real characteristics of the beam to column joints is possible.

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (I): Experimental study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.399-408
    • /
    • 2017
  • This paper experimentally studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Four beam-to-wall connection specimens with short and long embedded steel columns are tested under monotonic and cyclic loads, respectively. The influence of embedment length of columns on the failure mode and performance of connections is investigated. The results show that the length of embedded steel columns has significant effect on the failure mode of connections. A connection with a long embedded column has a better stiffness, load-bearing capacity and ductility than that of a short embedded column. The former fails due to the shear yielding of column web in the joint panel, while failure of the latter is initiated by the yielding of horizontal reinforcement in the wall due to the rigid rotation of the column. It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility.

Influence of post-pouring joint on long-term performance of steel-concrete composite beam

  • Huang, Dunwen;Wei, Jun;Liu, Xiaochun;Zhang, Shizhuo;Chen, Tao
    • Steel and Composite Structures
    • /
    • 제28권1호
    • /
    • pp.39-49
    • /
    • 2018
  • The concrete bridge decks are usually precast and in-situ assembled with steel girders with post-pouring joint in the construction practice of super-wide steel-concrete composite beam. But the difference of concrete age between the precast slabs and the post-pouring joint has been not yet considered for the long-term performance analysis of this kind composite beam. A simply supported precast-assembled T-shaped beam was taken as an example to analyze the long-term performance of steel-concrete composite beam with post-pouring joint. Based on the deformation coordination conditions of the old-new concrete deck and steel girder, a theoretical model for the long-term behavior of precast-assembled composite beam is proposed in this paper according to age-adjusted effective modulus method. Then, the feasibility of the proposed model is verified by the available test data from the Gilbert's composite beams. Parametric studies were preformed to evaluate the influences of the cross-sectional area ratio of the post-pouring joint to the whole bridge deck, as well as the difference of concrete age between the precast slabs and the post-pouring joint, on the long-term performance of the composite beam. The results indicate that the traditional method without considering the age difference would seriously underestimate the effect of creep and shrinkage of concrete bridge decks. The concrete age difference between the precast slabs and the post-pouring joint should be demonstrated for the life cycle design and long-term performance analysis of precast-assembled steel-concrete composite beams.

The Steel Coupling Beam-Wall Connections Strength

  • 박완신;윤현도
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

Experimental study on seismic performance of partial penetration welded steel beam-column connections with different fillet radii

  • Ge, Hanbin;Jia, Liang-Jiu;Kang, Lan;Suzuki, Toshimitsu
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.851-865
    • /
    • 2014
  • Full penetration welded steel moment-resisting frame (SMRF) structures with welded box sections are widely employed in steel bridges, where a large number of steel bridges have been in operation for over fifty years in Japan. Welding defects such as incomplete penetration at the beam-column connections of these existing SMRF steel bridge piers were observed during inspection. Previous experiments conducted by the authors' team indicate that gusset stiffeners (termed fillets in this study) at the beam-web-to-column-web joint of the beam-column connections may play an important role on the seismic performance of the connections. This paper aims to experimentally study the effect of the fillet radius on seismic performance of the connections with large welding defects. Four specimens with different sizes of fillet radii were loaded under quasi-static incremental cyclic loading, where different load-displacement relations and cracking behaviors were observed. The experimental results show that, as the size of the fillet radius increases, the seismic performance of the connections can be greatly improved.

Cyclic behaviour of concrete encased steel (CES) column-steel beam joints with concrete slabs

  • Chu, Liusheng;Li, Danda;Ma, Xing;Zhao, Jun
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.735-748
    • /
    • 2018
  • In this paper, the cyclic behavior of steel beam-concrete encased steel (CES) column joints was investigated experimentally and numerically. Three frame middle joint samples with varying concrete slab widths were constructed. Anti-symmetrical low-frequency cyclic load was applied at two beam ends to simulate the earthquake action. The failure modes, hysteretic behavior, ultimate load, stiffness degradation, load carrying capacity degradation, displacement ductility and strain response were investigated in details. The three composite joints exhibited excellent seismic performance in experimental tests, showing high load-carrying capacity, good ductility and superior energy dissipation ability. All three joint samples reached their ultimate loads due to shear failure. Numerical results from ABAQUS modelling agreed well with the test results. Finally, the effect of the concrete slab on ultimate load was analyzed through a parametric study on concrete strength, slab thickness, as well as slab width. Numerical simulation showed that slab width and thickness played an important role in the load-carrying capacity of such joints. As a comparison, the influence of concrete grade was not significant.

반복하중을 받는 철근콘크리트 연결보에서 강섬유의 보강효과에 관한 연구 (A Study on the Effect of Steel Fiber in Reinforced Concrete Coupling Beam Subjected to Cyclic Loading)

  • 김진성;배백일;최창식
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.181-190
    • /
    • 2019
  • In this study, four reinforced concrete coupling beams were subjected to cyclic lateral loading test to evaluate the structural performance of coupling beam according to volume fraction of steel fiber. For this purpose, the volume fraction of steel fiber(0%, 1%, 2%) and transverse reinforcement spacing were determined as the main parameter. According to the test results, the maximum strength of D-40C-s100-0 was 1.15, 1.13, 1.05 times higher than D-40C-s300-0, D-40C-s300-1, D-40C-s300-2, respectively. The maximum strength of coupling beams with mitigated rebar details increases as the volume fraction of steel fiber increases. Although steel fiber 2% reinforced specimen(D-40C-s300-2) did not satisfy the amount of transverse reinforcement required for seismic design of coupling beam, the overall performance including to maximum strength, ductility and energy dissipation capacity was similar to the control specimen(D-40C-s100-0). As a result, the use of steel fiber with 2% reinforcement can partially replace the transverse reinforcement in diagonally reinforced concrete coupling beam.

동일 내화뿜칠 피복조건에서 표준화재에 노출된 합성보의 강재 온도이력 및 단면형상계수와의 관계 (A Study on Relations between Shape Factor and Temperature History of Steel of Composit Beam in Standard Fire under Same Thickness Condition of Spray-type Fire Resistant Materials)

  • 여인환;조경숙;조범연
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.72-77
    • /
    • 2012
  • 콘크리트-강재 합성보가 고온에 노출된 경우 콘크리트는 강재를 피복하여 온도상승을 지연시키거나 보 내부의 수열용량을 높이는 역할을 한다. 한편 재료 간 일체화로 부재의 강도가 보완되기 때문에 일반적으로 단순 강재 보 보다 합성보의 내화성능이 유리하게 나타난다. 합성보에서 외부에 노출된 강재의 온도상승은 부재 단면의 형상 및 강재의 노출정도와 직접 관련하게 된다. 본 연구에서는 합성보와 일반철골보에 내화인정을 받은 내화뿜칠재를 동일 두께로 피복하여 표준화재조건의 내화실험을 실시하고, 그 결과로 나타난 강재의 온도이력과 단면형상계수와의 관계를 비교 분석하였다. 강재 온도 측정결과와 부재별 단면형상계수의 상관관계를 살펴본 결과 상관성이 매우 높은 것으로 나타났다. 이 결과는 부재의 내화성능에 영향을 미치는 명확한 조건에 의해 비교우위의 성능예측이 가능한 경우 부재별 개별 인정 없이 표준구조 인정을 통한 보편적인 사용이 가능할 수 있음을 시사한다.