• 제목/요약/키워드: Steady-state integral proportional integral control

검색결과 59건 처리시간 0.023초

Determination of PID Coefficients for the Ascending and Descending System Using Proportional Valve of a Rice Transplanter

  • Siddique, Md. Abu Ayub;Kim, Wan-Soo;Baek, Seung-Yun;Kim, Yeon-Soo;Choi, Chang-Hyun;Kim, Yong-Joo;Park, Jin-Kam
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.331-341
    • /
    • 2018
  • Purpose: This study was conducted to develop a linear Proportional-Integral-Derivative (PID) control algorithm for the ascending and descending system of a rice transplanter and to analyze its response characteristics. Methods: A hydraulic model using a single-acting actuator, proportional valve and a PID control algorithm were developed for the ascending and descending system. The PID coefficients are tuned using the Ziegler-Nichols (Z-N) method and the characteristics of unit step response are analyzed to select the PID coefficients at various pump speeds. Results: Results showed that the performance of the PID controller was superior in any condition. It was found that the highest settling time and maximum overshoot were less than 0.210 s and 5%, respectively at all pump speed. It was determined that the steady state errors were 0% in all the cases. The lowest overshoot and settling time were calculated to be nearly 2.56% and 0.205 s, respectively at the pump rated speed (2650 rpm). Conclusions: The results indicated that the developed PID control algorithm would be feasible for the ascending and descending system of a rice transplanter. Finally, it would be helpful to plant the seedlings uniformly and improve the performance of the rice transplanter.

Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters

  • Han, Yang;Shen, Pan;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.297-309
    • /
    • 2016
  • Grid-connected inverters (GCIs) with an LCL output filter have the ability of attenuating high-frequency (HF) switching ripples. However, by using only grid-current control, the system is prone to resonances if it is not properly damped, and the current distortion is amplified significantly under highly distorted grid conditions. This paper proposes a synchronous reference frame equivalent proportional-integral (SRF-EPI) controller in the αβ stationary frame using the parallel virtual resistance-based active damping (PVR-AD) strategy for grid-interfaced distributed generation (DG) systems to suppress LCL resonance. Although both a proportional-resonant (PR) controller in the αβ stationary frame and a PI controller in the dq synchronous frame achieve zero steady-state error, the amplitude- and phase-frequency characteristics differ greatly from each other except for the reference tracking at the fundamental frequency. Therefore, an accurate SRF-EPI controller in the αβ stationary frame is established to achieve precise tracking accuracy. Moreover, the robustness, the harmonic rejection capability, and the influence of the control delay are investigated by the Nyquist stability criterion when the PVR-based AD method is adopted. Furthermore, grid voltage feed-forward and multiple PR controllers are integrated into the current loop to mitigate the current distortion introduced by the grid background distortion. In addition, the parameters design guidelines are presented to show the effectiveness of the proposed strategy. Finally, simulation and experimental results are provided to validate the feasibility of the proposed control approach.

Robust PID $\times$ (n-1) Stage PD Controller

  • Numsomran, Arjin;Julsereewong, Prasit;Ukakimaparn, Prapart;Trisuwannawat, Thanit;Tirasesth, Kitti
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.298-301
    • /
    • 1999
  • This paper presents a design technique based on the root locus method fur a class of $n^{th}$ order plants using PID (Proportional-Integral-Derivative) x (n-1) stage PD controller. It is intended to satisfy both transient and steady state response specifications. This controller can be used instead of a conventional PID controller for the higher order plants to obtain better performances. The controlled system is approximated as a stable and robust second order controlled system. Only adjusting the controller gain, the desired performances of the controlled system are satisfied. For the stable plant including the plant with small dead time, the controlled system is made robustly stable. In case of the unstable plant, when the controller gain is adjusted higher than the critical value, the unstable plant can also be made stable. Robustness properties given by this controller proposed in this paper have also been demonstrated by numerical examples.

  • PDF

A Novel Photovoltaic Power Harvesting System Using a Transformerless H6 Single-Phase Inverter with Improved Grid Current Quality

  • Radhika, A.;Shunmugalatha, A.
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.654-665
    • /
    • 2016
  • The pumping of electric power from photovoltaic (PV) farms is normally carried out using transformers, which require heavy mounting structures and are thus costly, less efficient, and bulky. Therefore, transformerless schemes are developed for the injection of power into the grid. Compared with the H4 inverter topology, the H6 topology is a better choice for pumping PV power into the grid because of the reduced common mode current. This paper presents how the perturb and observe (P&O) algorithm for maximum power point tracking (MPPT) can be implemented in the H6 inverter topology along with the improved sinusoidal current injected to the grid at unity power factor with the average current mode control technique. On the basis of the P&O MPPT algorithm, a power reference for the present insolation level is first calculated. Maintaining this power reference and referring to the AC sine wave of bus bars, a sinusoidal current at unity power factor is injected to the grid. The proportional integral (PI) controller and fuzzy logic controller (FLC) are designed and implemented. The FLC outperforms the PI controller in terms of conversion efficiency and injected power quality. A simulation in the MATLAB/SIMULINK environment is carried out. An experimental prototype is built to validate the proposed idea. The dynamic and steady-state performances of the FLC controller are found to be better than those of the PI controller. The results are presented in this paper.

바이오 기반 2,3-butanediol 증류 공정의 제어 및 동적 최적화 (Process Control and Dynamic Optimization of Bio-based 2,3-butanediol Distillation Column)

  • 이기열;안나현;임종구;한인수;조형태;김정환
    • Korean Chemical Engineering Research
    • /
    • 제61권2호
    • /
    • pp.217-225
    • /
    • 2023
  • 화장품, 비료 등 다양한 분야에서 사용되는 2,3-butanediol (2,3-BDO) 는 고부가가치 물질로 그 수요가 점차 증가하고 있다. 미생물의 발효로부터 생산된 2,3-BDO는 발효의 부산물을 포함하고 있을 뿐만 아니라 발효 조건에 따라 피드 조성의 변동이 심하여 생산물의 목표 순도에 도달하기 위한 분리 공정의 효율적인 운전이 어렵다. 따라서 본 연구에서는 바이오 기반 2,3-BDO 증류 공정의 동적 최적화를 통해 피드의 농도가 변화할 때 하단 생산물의 2,3-BDO 농도를 99 wt% 이상으로 제어할 수 있는 최적의 제어 경로를 탐색하였다. 정상 및 동적 상태 공정 모사와 Proportional integral (PI) 제어기 설계 후 동적 최적화를 차례로 수행하였다. 그 결과 하단 생산물의 2,3-BDO 농도와 설정점 사이의 오차가 75.2% 감소하였다.

PR제어기를 이용한 단상 계통 연계형 태양광 인버터 설계 (PR Controller Based Current Control Scheme for Single-Phase Inter-Connected PV Inverter)

  • 부우충기엔;성세진
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3587-3593
    • /
    • 2009
  • 최근 태양광 시스템에서는 기존의 태양광 시스템을 계통과 전원으로 상호 접속하는 것에 대한 연구에 관심이 모아지고 있다. 단상, 삼상 시스템에 관계없이 태양광 시스템에서 태양광 인버터는 계통연계 동작에 중요한 역할을 하기 때문에 전체 시스템에서 핵심요소로 고려된다. 태양광 인버터를 제어하기 위해서는 부하 전류 조절이 핵심요소 중 하나이다. 일반적으로 태양광 인버터에서 이용되는 PI 제어기는 정상상태 오차와 왜란에 취약하다는 단점을 가지고 있기 때문에 실제 시스템에 완벽하게 적용하기에는 무리가 있다. 특히, 이는 고주파영역에서의 PI와 PR 제어기의 성능을 비교해보면 알 수 있다. 이 논문에서 제시된 PR 제어기는 무한 이득을 교류 기본파 성분에 넣을 수 있기 때문에 PR 제어기는 회전좌표계의 PI 제어기에서 사용되는 디커플링 기법과 복잡한 변환 없이 제로 정상상태오차에 도달할 수 있다. 그렇기 때문에 이 논문에서는 PI 제어기를 대체하는 이론적 분석을 통해 PR 제어기를 설계하였다. 논문에 제시되어 있는 이론을 바탕으로 한 PR 제어기를 고정 소수점 연산방식의 32비트 마이크로컨트롤러 DSP320F2812를 기반으로 한 3kW 프로토타입 태양광 인버터에 적용, 평가하였다. 또한 태양광 인버터의 제어 성능을 시뮬레이션과 실험결과를 통하여 보여주고 검증하였다.

전자유압 비례밸브와 경사센서를 이용한 농용 프론트 로더 버켓 능동수평유지 시스템 개발 (Development of a self-leveling system for the bucket of an agricultural front-end loader using an electro hydraulic proportional valve and a tilt sensor)

  • 이창주;하종우;최덕수;김학진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제12권4호
    • /
    • pp.60-70
    • /
    • 2015
  • A front-end loader (FEL) mounted on an agricultural tractor is one of the most commonly used implements for farm work. However, when the tractor carries material using the bucket attached to the FEL on a sloping ground, the materials can spill or roll back over the operator due to the tilted body, thereby requiring the bucket surface to remain level at a constant value regardless of varying slopes. In this study, an active system for controlling the angle of the FEL bucket on a tractor based on the real-time measurement of ground slopes was developed to enable the bucket to constantly remain level. A FEL simulator operated based on an electro hydraulic proportional valve (EHPV) was constructed in the laboratory to develop a proportional-integral-derivative (PID) controller forming a virtual electronic control unit (ECU) on the computer, which could automatically adjust the bucket angles depending on varying input angles while sending SAE-J1939 associated messages via CAN BUS to the EHPV. The different parameter values for the PID controller due to the gravity effect of the bucket were determined using a manual PID tuning method while assuming that the tractor travels on either an ascending slope or a descending slope. The developed PID control-based self-leveling system showed a mean of steady-state errors of within $1^{\circ}$ and a mean of delayed times of ~ 0.8s when the step input of $+20^{\circ}$ was given, implying that the developed system and control algorithm would be effective in maintaining the bucket angle at a certain value. Future studies include the improvement of the control algorithm to reduce such a time delay as well as the application of the developed algorithm to the FEL mounted on a tractor tested at a testing ground.

활성슬러지 공정을 위한 모델링과 지능제어의 적용 (Modeling and Intelligent Control for Activated Sludge Process)

  • 천성표;김봉철;김성신;김창원;김상현;우혜진
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1905-1919
    • /
    • 2000
  • 활성슬러지 공정에 기반을 둔 연속식반응기는 시스템이 가진 고유한 비선형성뿐만 아니라 계절, 기후 등의 환경변화에 따른 유입수의 유량 및 특성 등의 외부적인 조건의 변화를 고려하여 제어하여야 한다. 수학적 모델링 과정에서 고려하지 못했거나 무시되었던 부분을 포함한 시스템에 관련된 특징과 한정된 공간에서 기본적인 제어방법에 의한 현재의 운전방법을 고려하여 불 때 활성슬러지 공정은 개선할 수 있는 여지가 많다. 또한 숙련된 운전자의 지식을 구현할 수 있는 지능제어기법을 적용하여 전체적인 공정의 효율 향상을 도모할 수 있다. 제어방법의 적용에 앞서 제어대상공정인 활성슬러지 공정을 분석하여 이를 $Matlab^{(R)}5.3/Simulink^{(R)}3.0$을 이용하여 연속식반응기 모델을 구현하였다. IWA(International Water Association)와 COST(European Cooperation in the field of Scientific and Technical Research)에서 제시한 정상상태의 유입수 특성을 이용하여 모델의 정확성을 검증하였다. 본 논문에서는 이미 현장에서 사용중인 제어기법의 구현 및 성능 평가뿐만 아니라 다양한 고급제어기법들을 적용하여 새롭게 제안한 제어기법들이 실제 폐수처리장에 적용가능한지 여부를 검증하였다. 제어방법으로는 현장에서 일반적으로 사용되고 있는 비례-적분-미분제어기(Proportional-Integral-Derivative Controller; PID controller)와 PID제어기가 가진 장점과 퍼지 논리 제어기법이 가진 장점을 결합함과 동시에 제어기의 성능 향상 및 경제성을 높일 수 있는 퍼지 PID이득 조절기(fuzzy PID gain tuner)와 퍼지 셋포인트 변환기(fuzzy setpoint changer)를 적용하여 봄으로써 외란에 대해 강인한 제어기 설계의 가능성을 검증하였다.

  • PDF

비선형 PID 제어기를 이용한 선박용 가스터빈 엔진의 속도 제어 (Speed Control of Marine Gas Turbine Engine using Nonlinear PID Controller)

  • 이윤형;소명옥
    • 한국항해항만학회지
    • /
    • 제39권6호
    • /
    • pp.457-463
    • /
    • 2015
  • 가스터빈 기관은 우주항공, 발전 플랜트뿐만 아니라 해상운송 분야에 사용되는 원동기로서 매우 중요한 역할을 하고 있다. 그러나 그 구조가 복잡하고 연소과정에서 시간지연 요소가 포함되어 있어 가스터빈 기관을 잘 제어할려면 정교한 수학적 모델링이 필요하다. 본 논문에서는 가스터빈 기관의 주요 구성품인 가스발생기, PLA 액추에이터, 미터링 밸브에 대한 모델링 기법을 설명한다. 또한, 가스터빈 기관의 시운전 데이터를 기초로 몇 가지 정상상태 때의 동작점에서 서브모델을 구하고, 각 서브모델에 대해 비선형 비례적분미분 제어기를 설계하여 기관의 속도를 제어하는 방법을 제안한다. 제안하는 비선형 제어기는 비선형 함수로 구현되는 3가지 이득을 사용한다. 비선형 제어기의 파라미터는 제어시스템의 목적함수를 최소화하는 관점에서 실수코딩 유전자알고리즘으로 동조한다. 제안한 방법은 가스터빈 기관에 적용하고 시뮬레이션을 실시하여 그 유효성을 확인한다.