• 제목/요약/키워드: Steady-state Response

검색결과 655건 처리시간 0.032초

하프 브릿지 병렬-직렬 공진형 컨버터의 주파수 특성에 관한 연구 (A Study On the Frequency Characteristic of the HBPSRC)

  • 차인수;박해암
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1992년도 추계학술발표회논문집
    • /
    • pp.51-55
    • /
    • 1992
  • By using the state plane approach, the steady state analysis and design of a half bridge parallel-series (LLC-type) resonant converter (HBPSRC) operating in the continous conduction made is presented. The state-plane diagram representation of the converter response gives good insight into the converter operation. Based on this analysis, a set of steady state characteristic waves for HBPSRC is presented. A simple design procedure is given and design example for a 100watts, 30KHz HBPSRC is presented for illustrative purposes.

  • PDF

PD+I-type fuzzy controller using Simplified Indirect Inference Method

  • Kim, Ji-Hoon;Jeon, Hae-Jin;Chun, Kyung-Han;Park, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.179.5-179
    • /
    • 2001
  • Generally, while PD-type fuzzy controller has good performance in transient period, it has uniform steady state error of response. To improve limitations of PD-type fuzzy controller, we propose a new fuzzy controller to improve the performance of transient response and to eliminate the steady state error of response. In this paper, PD-type fuzzy controller is used a simplified indirect inference method(SIIM). When the SIIM is applied, the proposed method has the capability of the high speed inference and adapting with increasing the number of the fuzzy input variables easily. The outputs of this controller are the output calculated by PD-type fuzzy controller and the accumulated error scaling factor. Here, the accumulated error scaling factor is adjusted by fuzzy rule according to the system state variables. To show the usefulness of the proposed controller, it is applied to 0-type 2nd-order linear system.

  • PDF

3GPP 모뎀용 동기 추적회로의 설계 및 성능 분석 (Design and Performance Analysis of a Noncoherent Code Tracking Loop for 3GPP MODEM)

  • 양연실;박형래
    • 한국통신학회논문지
    • /
    • 제28권12A호
    • /
    • pp.983-990
    • /
    • 2003
  • 본 논문에서는 3GPP 모뎀용 비동기식 동기추적회로(noncoherent code tracking loop)를 설계하고 설계된 회로의 정상상태 지터 분산(steady-state jitter variance)과 과도응답 특성(transient response characterisitc)을 해석한다. 먼저, AWGN 환경에서의 지터 분산을 펄스성형 필터(pulse-shaping filter), 타이밍 오프셋(timing offset), 신호 대잡음비(signal-to-interference ratio), 루우프 대역폭(loop bandwidth)에 대한 일반식으로 유도하고, 과도응답 특성을 이론적으로 해석한다. 이를 바탕으로, 디지털 하드웨어 구현이 용이한 가변 대역폭 동기추적회로를 설계하며 설계된 회로와 고정 대역폭 시스템의 성능을 이론적으로 비교, 분석하고 컴퓨터 시뮬레이션을 통해 검증한다.

Steady-State and Transient Response Analysis of DSSC Based on Electron Diffusion Coefficient and Chemical Capacitance

  • J. C. Gallegos;J. Manriquez;R. Rodriguez;S. Vargas;D. Rangel
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권2호
    • /
    • pp.276-290
    • /
    • 2024
  • A study of the transition from transitory state to steady state in DSSCs based on natural dyes is presented; cochineal was used as dye and Li+, Na+, and K+ were the ions added to the electrolyte. The photocurrent profiles were obtained as a function of time. Several DSSCs were prepared with different cations and their role and the transitory-to-steady transition was determined. A novel hybrid charge carrier source model based on the Heaviside function H(t) and the Lambert-Beer law, was developed and applied to analysis of the transient response of the output photocurrent. Additionally, the maximum effective light absorption coefficient α and the electronic extraction rate κ for each ion were determined: ${\alpha}_{Li^+,Na^+,K^+}\,=\,(0.486,\,0.00085,\,0.1126)\,cm^{-1}$, and also the electronic extraction rate ${\kappa}^{Li^+,Na^+,K^+}_{ext.}\,=\,(1410,\,19.07,\,19.69)\,cm\,s^{-1}$. The impedance model using Fick's second law was developed for carrier recombination to characterize the photocurrent.

Redesigning Taguchi Sensor

  • Hossein-Babaei Faramarz;Park, Won-Kyu
    • 한국세라믹학회지
    • /
    • 제42권1호
    • /
    • pp.11-15
    • /
    • 2005
  • The configuration of the main components and the physical structure of the Taguchi sensor, the first ceramic gas sensor mass produced, has remained virtually unaltered since its appearance 40 years ago. This device owns an excellent combination of the quality factors but is non-selective. The research efforts carried out to enhance the selectivity in this resistive gas sensor are briefly reviewed. A novel design, Capillary-attached Gas Sensor (CGS), is introduced, which employs the same ceramic components used for the fabrication of a classical Taguchi sensor but in altered geometries. CGS presents remarkable advantages from the view point of selectivity over the original design. While the steady state response of a CGS has the same significance as that of the Taguchi sensor, its transient response presents valuable diagnostic information. Fabrication and test of a prototype CGS is reported.

활성슬러지공정의 수리학적 충격부하 반응 (Hydraulic Shock Load Response of Activated Sludge Process)

  • 황규대;김민호;고새봄;조철휘
    • 상하수도학회지
    • /
    • 제11권3호
    • /
    • pp.67-78
    • /
    • 1997
  • The objective of study was to examine to transient response of hydraulic shock loading in activated sludge process for treatment of municipal sewage. The general experiment approach was to operate the system under steady-state(pre-shock), then to apply step changes during 24hours in fourfold hydraulic shock loading at the same organic loading. Performance was assessed in both the transient state and the new steady-state(post-shock). Three bench scale activated sludge reactors were operated to investigate the effect of fourfold hydraulic shock loading on TSS and COD removal efficiency. In activated sludge reactors operated with 13hours and 7hours of HRT, effluent quality of all reactors was not changed for few effects, and also showed no foaming and no sludge bulking. Those results are the same as sludge withdrawn reactors. The effect of fourfold hydraulic shock loading on the activated sludge reactors operated with 3hours of HRT was most severe. The effluent quality was deteriorated significantly and generate foaming in reactors. Less than 24hours after the fourfold shock loading applied, the activated sludge system seemed to attain a new steady-state condition as show by effluent.

  • PDF

그리드/연계선 사고 시 풍력발전단지의 응동 분석 (Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions)

  • 이혜원;김연희;정태영;이상철;강용철
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.

입출력 부공간에서의 데이터 클러스터링에 의한 퍼지제어 시스템 설계 (Fuzzy control system design by data clustering in the input-output subspaces)

  • 김민수;공성곤
    • 전자공학회논문지S
    • /
    • 제34S권12호
    • /
    • pp.30-40
    • /
    • 1997
  • This paper presents a design method of fuzzy control systems by clustering the data in the subspace of the input-output produyct space. In the case of servo control, most input-outputdata are concentrated in thye steady-state region, and the the clustering will result in only steady-state fuzzy rules. To overcome this problem, we divide the input-output product space into some subspaces according to the state of input variables. The fuzzy control system designed by the subspace clustering showed good transient response and smaller steady-state error, which is comparable with the reference fuzzy system.

  • PDF

A remedy for a family of dissipative, non-iterative structure-dependent integration methods

  • Chang, Shuenn-Yih;Wu, Tsui-Huang
    • Earthquakes and Structures
    • /
    • 제14권1호
    • /
    • pp.45-53
    • /
    • 2018
  • A family of the structure-dependent methods seems very promising for time integration since it can simultaneously have desired numerical properties, such as unconditional stability, second-order accuracy, explicit formulation and numerical dissipation. However, an unusual overshoot, which is essentially different from that found by Goudreau and Taylor in the transient response, has been experienced in the steady-state response of a high frequency mode. The root cause of this unusual overshoot is analytically explored and then a remedy is successfully developed to eliminate it. As a result, an improved formulation of this family method can be achieved.

Sine sweep effect on specimen modal parameters characterization

  • Roy, Nicolas;Violin, Maxime;Cavro, Etienne
    • Advances in aircraft and spacecraft science
    • /
    • 제5권2호
    • /
    • pp.187-204
    • /
    • 2018
  • The sine sweep base excitation test campaign is a major milestone in the process of mechanical qualification of space structures. The objectives of these vibration tests are to qualify the specimen with respect to the dynamic environment induced by the launcher and to demonstrate that the spacecraft FE model is sufficiently well correlated with the test specimen. Dynamic qualification constraints lead to performing base excitation sine tests using a sine sweep over a prescribed frequency range such that at each frequency the response levels at all accelerometers, load cells and strain gages is the same as the steady state response. However, in practice steady state conditions are not always satisfied. If the sweep rate is too high the response levels will be affected by the presence of transients which in turn will have a direct effect on the estimation of modal parameters. A study funded by ESA and AIRBUS D&S was recently carried out in order to investigate the influence of sine sweep rates in actual test conditions. This paper presents the results of this study along with recommendations concerning the choice of methods.