• 제목/요약/키워드: Steady State Responses

검색결과 180건 처리시간 0.033초

DC-link전류정보를 기반으로 한 새로운 SRM 구동시스템 (Novel SRM Drive System Based on the DC-link Current Information)

  • 김주진;김성곤;이주환;김태웅
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.6-10
    • /
    • 2004
  • This paper newly proposes the SRM drive system based on DC-link current information, from which the phase currents can be estimated in accuracy and also they can be used in driving SRM instead of the phase currents. Comparing to the general drive system based on the phase current information, it is verified through the simulation(which are peformed by RMxprt and Simplorer) that the proposed SRM drive system has the good performance in dynamic and steady-state responses of the speed control. Using the DC-link current information, all of the multi-phase currents can be easily estimated in driving the SRM.

  • PDF

이감직신간 제어계에 있어서 Routh안정기열과 MSE 을 이용한 새로운 혼합형 모델 절기법 (A New Combined Approximation for the Reduction of Discrete-Time Systems Using Routh Stability Array and MSE)

  • 권오신;김성중
    • 대한전기학회논문지
    • /
    • 제36권8호
    • /
    • pp.584-593
    • /
    • 1987
  • A new combined approximation method using Routh stability array and mean-square error (MSE) method is proposed for deriving reduced-order z-transter functions for discrete time systems. The Routh stability array is used to obtain the reduced-order denominator polynomial, and the numerator polynomial is obtained by minimizing the mean-square error between the unit step responses of the original system and reduced model. The advantages of the new combined approximation method are that the reduced model is always stable provided the original model is stable and the initial and steady-state characteristics of the original model can be preserved in the reduced model.

Zn(II)porphyrin Helical Arrays: A Strategy to Overcome Conformational Heterogeneity by Host-Guest Chemistry

  • Yoon, Zin-Seok;Easwaramoorthi, Shanmugam;Kim, Dong-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권1호
    • /
    • pp.197-201
    • /
    • 2008
  • Conformational heterogeneity of directly linked multiporphyrin arrays with larger molecular length retards their utilities in practical applications such as two-photon absorption and molecular photonic wire. In this regard, here we adopted a way to overcome the conformational heterogeneity through hydrogen bonding by selective binding of meso aryl substituents of porphyrins (host) with urea (guest) to form helical structure. Using steady-state and time-resolved spectroscopy, we observed the enhanced fluorescence quantum yield by ~1.8 to 2.4 times, enhanced anisotropy values and the disappearance of fast fluorescence decay component in the host-guest helical forms. In addition, the enhanced nonlinear optical responses of helical arrays infer the extended inter-porphyrin electronic coupling due to a significant change in dihedral angle between the neighboring porphyrin moieties. The current host-guest strategy will provide a guideline to improve the structural homogeneity of the photonic wire.

계통주파수 및 전압 저하시 원자력발전소 응동 분석 (Studies on Dynamic Responses of Nuclear Power Plant during Frequency and Voltage Decays)

  • 조성돈;강인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1221-1223
    • /
    • 1999
  • The safety loads in a nuclear power plant perform a critical function to plant safety. The design of the electrical auxiliary system should ensure the availability and adequacy of the power supply, and therefore, the frequency and voltage relaying schemes should be installed on the system to monitor and protect against the degraded system condition. If unforeseen contingencies degrade the switchyard frequency and voltage to below the minimum values, the safety related bus should properly be transferred to alternate power source. This paper presents guidelines associated with the protection of nuclear power plants during frequency/voltage decay and the steady-state and dynamic analysis of auxiliary power system that should be performed to support the degraded voltage relay(second level undervoltage relay) setting.

  • PDF

임계각속도 주변에서의 회전 외팔보의 동역학 (Dynamics of a Rotating Cantilever Beam Near Its Critical Angular Speed)

  • 최창민;유홍희
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1231-1237
    • /
    • 2000
  • Dynamics of a rotating cantilever beam near its critical angular speed is investigated in this paper. The external, force is idealized as a periodic function which has the same period as the rotati ng frequency of the beam. The equations of motion are derived and transformed into a dimensionless form. A prescribed spin-up motion is employed for the rotating motion. Numerical study shows that the steady state and the transient responses of the beam are affected by the spin-up time constant and there exists a time constant at which the maximum transient response becomes minimum.

Rate-sensitive analysis of framed structures Part I: model formulation and verification

  • Izzuddin, B.A.;Fang, Q.
    • Structural Engineering and Mechanics
    • /
    • 제5권3호
    • /
    • pp.221-237
    • /
    • 1997
  • This paper presents a new uniaxial material model for rate-sensitive analysis addressing both the transient and steady-state responses. The new model adopts visco-plastic theory for the rate-sensitive response, and employs a three-parameter representation of the overstress as a function of the strain-rate. The third parameter is introduced in the new model to control its transient response characteristics, and to provide flexibility in fitting test data on the variation of overstress with strain-rate. Since the governing visco-plastic differential equation cannot be integrated analytically due to its inherent nonlinearity, a new single-step numerical integration procedure is proposed, which leads to high levels of accuracy almost independent of the size of the integration time-step. The new model is implemented within the nonlinear analysis program ADAPTIC, which is used to provide several verification examples and comparison with other experimental and numerical results. The companion paper extends the three-parameter model to trilinear static stress-strain relationships for steel and concrete, and presents application examples of the proposed models.

하드디스크 드라이브 회전축계의 강제진동해석 (Forced Vibration Analysis of the Hard Disk Drive Spindle Systems)

  • 임승철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1601-1608
    • /
    • 2000
  • This paper is concerned with the forced flexural vibration analysis of hard disk drive (HDD) spindle systems with multiple thin disks, supported by two ball bearings based on the finite element model. This is the extension of the previous work which analytically modeled every system component taking into account its structural flexibility and also the centrifugal stiffening effect especially for the disks. Among the end results, the forced time response is expectedly useful for the vibration control of the spindle itself or the position servo control of the magnetic head. On the other hand, the steady state responses such as the frequency response function and the unbalance response are useful for system identification. Futhermore, through a coordinate transformation the equations of motion is also derived with respect to the inertial frame for convenient analyses of certain classes.

  • PDF

제어량의 크기를 조건부에 포함하는 PI형 퍼지제어기 (A PI-Type Fuzzy Controller Taking Control Input into Conditional Part of Rules)

  • Ji Hong Lee
    • 전자공학회논문지B
    • /
    • 제30B권5호
    • /
    • pp.109-119
    • /
    • 1993
  • To improve limitations of fuzzy PI controllers especially when applied to systems of order higher than one, we propose a fuzzy PI controller that takes out appropriate amounts of accumulated control input according to fuzzily described situations in addition to the calculation of incremental control input as in the case of conventional fuzzy PI controllers. The structure of the proposed controller was motivated by the characteristics of fuzzy PI controller that it generally gives inevitable overshoot when one tries to reduce rise time of the response especially when a system of order higher than one is under consideration. Since the undesirable characteristics of the fuzzy PI controller is caused by integrator of the controller, even though the integrator is introduced to overcome steady state error of response, we propose a controller that fuzzily clears out integrated quantities according to situation to give reduced rise time as well as small overshoots. To show the usefulness of the proposed controller, it is applied in simulations to such systems as are difficult to stabilize or difficult to get satisfactory responses by conventional fuzzy PI controllers.

  • PDF

A Neuro Fuzzy Controller for DC-DC Converters

  • Huh, Sung-hoe;Hwang, Yong-Ha;Park, Gwi-Tae;Choy, Ick
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.420-424
    • /
    • 1998
  • A new type of controller for DC-DC converters is presented. The proposed neuro-fuzzy controller combines fuzzy logic with neural networks to adjust parameters of the fuzzy controller to the most appropriate. Neither the exact mathematical models of the DC-DC converters nor the tuning process of the parameters of the fuzzy controller are needed in the proposed scheme. Simulation results are presented to show the above process and transient, steady state responses, and load regulation of the given system.

  • PDF

고정 커플링의 오프셋을 갖는 발전용 가스터빈-발전기의 동적 응답해석 (Dynamic Response Analysis of a Heavy Duty Gas Turbine-Generator with Rigid Coupling Offset)

  • 하진웅;정대석
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.70-75
    • /
    • 2014
  • In this paper a analysis method is presented to obtain the steady state dynamic response from the finite element based equations of a rotor-bearing system with initial deflection. The method has been applied to analyze the dynamic response of the two-shaft rotor-bearing system with rigid coupling offset in a heavy duty gas turbine-generator. Bumps in the dynamic response of each rotor system have been observed at each critical speed due to the effect of initial deflection for rigid coupling offset. And, the dynamic responses have been shown to reduce for operating condition changes from cold to hot.