• Title/Summary/Keyword: Stator winding

Search Result 425, Processing Time 0.042 seconds

A technology State of Accelerating Degradation and Life Estimation on the Traction Motor for Railway Rolling Stock (철도차량 견인전동기의 가속열화수명평가 기술현황)

  • Wang, Jong-Bae;Kim, Ki-Jun;Choi, Young-Chan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.25-28
    • /
    • 2000
  • In this paper, the technology for accelerating degradation & life estimation on the traction motor was introduced with the stator form-winding sample coils of the 200 Class insulation system The accelerative degradation was performed in 10 cycles, which were composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of $20{\sim}160^{\circ}C$. Relationship between degradation conditions and diagnosis results were analyzed to find an dominative degradation factor at the end-life point

  • PDF

Power and loss characteristics of PMSM/G with double-sided Halbach magnetized rotor (양측식 Halbach 자화 회전자를 갖는 영구자석 동기 전동발전기의 출력 및 손실 특성)

  • Jang, Seok-Myeong;You, Dae-Joon;Choi, Sang-Kyou
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.723-724
    • /
    • 2008
  • The rotational loss is one of the most important problems for the practical applications of PM synchronous motor/generator. This rotational loss is divided as the mechanical loss by windage and bearing and iron loss by hysteresis loop and eddy current in the part of the magnetic field. So, In this paper, a double-sided PMSM/G without the iron loss is designed by analytical method of the magnetic field and estimation of the back-EMF constant represented as the design parameter. This design model consists of the double-sided PM rotor with Halbach magnetized array and coreless 3-phase winding stator. The results show that the double-sided PMSM/G without iron loss can be applicable to the required system without the rotational loss.

  • PDF

Insulation Characteristic of Stator Winding for Large Capacity Hydorgenerator (대용량 수력발전기 고정자권선의 절연특성고찰)

  • Oh, Bong-Keun;Lee, Kwang-Ho;Kim, Hyun-Il;Byun, Doo-Gyoon;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2042-2043
    • /
    • 2008
  • 수력발전기의 운전중 신뢰성 및 장기 사용된 발전기의 경우 노후도 평가를 위한 지표로 고정자권선의 물리적 절연상태를 평가하는 방법이 일반적으로 이용되고 있다. 시험방법은 크게 부분방전 특성을 검출하는 운전중(On-line) 진단기법과 정지중(Off-line) 진단기법이 있다. 운전중 진단기법은 발전기의 정지없이 상시 상태를 감시할 수 있는 장점이 있으므로 활용도가 증가되고 있고 정지중 진단기법은 고정자권선 절연상태를 정밀하게 평가할 수 있는 잘 알려진 시험법으로 권선의 절연상태를 모니터링하여 운영자에게 고장징후를 알려주고, 예측보전이 가능하도록 도움을 주고 있다. 이 논문에서는 장기간 운영된 대용량 수력발전기의 정지중 절연진단기법(성극지수, 교류전류, 유전정접, 부분방전) 결과의 통계적 추이변화 고찰을 통하여 대용량 수력발전기 고정자 권선의 신뢰성평가를 실시하였다.

  • PDF

Electromagnetic Characteristic and Excitation Force Analysis of 10kW High Speed Induction Motor According to Stator Winding Specifications (고정자 권선 사양에 따른 10kW급 고속 유도전동기의 전자기적 특성 및 가진력 분석)

  • Lee, Ji-Young;Jang, Dae-Kyu;Chang, Jung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.748-749
    • /
    • 2015
  • 본 논문에서는 권선사양에 따른 10kW급 동 다이캐스팅 고속 유도전동기의 전자기적 특성과 전기기기의 진동을 발생시키는 고정자 치의 가진력을 분석하였다. 회전자 모델과 코일의 점적률은 일정하게 유지하면서 턴 수, 코일단면적, 고정자 슬롯의 형상을 변경하였다. 이에 따라 1, 2차 측 저항과 누설리액턴스 성분이 변화함을 확인하였고, 저항과 누설리액턴스 성분의 변화가 유도전동기의 토크, 자속밀도, 효율 특성 및 고정자 치의 가진력에 미치는 영향에 대해 분석하였다.

  • PDF

Impact of Eccentricity and Demagnetization Faults on Magnetic Noise Generation in Brushless Permanent Magnet DC Motors

  • Rezig, Ali;Mekideche, Mohammed Rachid;Djerdir, Abdesslem
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.356-363
    • /
    • 2011
  • Vibrations and noise in electrical machines are directly related to the characteristics of the radial forces on one hand, and mechanical behavior on the other [1, 4]. The characteristics of these forces depend on the air gap flux density, which is also influenced by other factors, such as stator slots and poles, saturation level, winding type, and certain faults. The aim of this work is to investigate the effect of eccentricity and demagnetization faults on electromagnetic noise generated by the external surface of Permanent Magnet Synchronous Machine [PMSM]. For this purpose, an analytical electromagnetic vibroacoustic model is developed. The results confirm the effect of eccentricity and demagnetization fault in generating some low modes radial forces.

Assessment of Insulation Condition for Hydro-generator (대용량 수치발전기의 절연진단에 의한 절연상태평가)

  • Lee, Kwang-Ho;Park, Jong-Jin;Kim, Ki-Won;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1810-1812
    • /
    • 2002
  • This test was performed to assess the insulation deterioration condition of the stator winding of Chung-Ju hydrogenerator #4 and Dae-Cheong hydrogenerator #2 which had been in service after being constructed 1980. The insulation diagnostic tests include resistance polarization index(P.I.) AC current, dissipation factor(Tan ${\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to factory test measurements.

  • PDF

Nonlinear Analysis of the Rotor Bridge in a Induction Motor with Closed Slots (폐슬롯 구조의 회전자를 가지는 유도전동기 회전자 브릿지부분의 자기포화현상 해석)

  • Lee, Hak-Yong;Hahn, Song-Yop;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.27-29
    • /
    • 1999
  • The starting characteristics of induction motors strongly depend on the leakage reactance and resistance of stator winding and rotor circuits. The magnetic field saturation in the rotor bridge of closed slot rotor makes it very difficult to compute the leakage reactance of rotor bars. This paper describes a comparison between timestep finite element analysis, time-harmonic analysis and experimental results for a test model which can represent the nonlinear behaviour of the rotor bridge.

  • PDF

Determination of Induction Motor equivalent circuit parameters by Inverter Source (인버터 전원에 의한 유도전동기 등가회로 결정)

  • Jeong, Young-Jun;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.160-162
    • /
    • 2001
  • A determining method of the $\Gamma$ type eqivalent circuit parameters of induction motor driven by inverter source is proposed in this paper. The no-load test by rated frequency (60 Hz) and a blocked rotor test by 25% of rated frequency (l5Hz) are performed with inverter source, and the DC resistance of the stator winding is measured. To determine the more accurate parameters, four simultaneous equations obtained from equivalent circuit of the no-load test and blocked rotor test are solved by using initial values which are evaluated from simplified equivalent circuits. The induction motor performances are computed by using these parameters and compared with measured values of the tested motor. Then it is found that the compared results show good agreement between them.

  • PDF

Evaluation on Insulation Performance of Low-voltage Induction Motors by Partial Discharge Measurement (부분방전 측정에 의한 저압용 유도전동기의 절연성능 평가)

  • Park, Dae-Won;Choi, Su-Yeon;Choi, Jae-Sung;Kil, Gyung-Suk;Lee, Kang-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1887-1891
    • /
    • 2008
  • In this paper, we dealt with a partial discharge (PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage induction motors. The PD measurement system consists of a coupling network, a low noise amplifier, and associated electronics. A shielded box was used to reduce environmental noise. Frequency characteristic of the coupling network was estimated by a sinusoidal signal input, and the low cut-off frequency of the coupling network was 1 MHz (-3 dB). Also, we carried out a calibration test for the PD measurement system. Sensitivity of the system was of 84 m$V_{max}$/pC between stator winding and enclosure. In application test on a low-voltage three phase induction motor (5 HP), we could detect 88 pC at AC 800 $V_{max}$.

  • PDF

Characteristic Analysis and Test of IPMSM for e-4WD of the Hybrid Electric Vehicle (HEV용 e-4WD 구동을 위한 매입형 영구자석 동기전동기의 특성해석 및 시험)

  • Jung, Soo-Jin;Lee, Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.777-784
    • /
    • 2016
  • In this paper, the performance design and analysis for an Interior Permanent-Magnet Synchronous Motor (IPMSM) that will be used as a traction motor in the e-4WD system of hybrid SUV(Sports Utility Vehicle) and RV(Recreational Vehicle), are investigated using finite element method. In order to improve the accuracy of design, the tolerances of parts and assemblies as well as the material properties of permanent magnet, stator, rotor and winding etc. are considered under the conditions similar to real driving state of motor. Both no load performance test and maximum load performance test, in which real driving state and cooling condition have been considered, are also implemented via proto sample build to verify the validity of motor's performance design.