• 제목/요약/키워드: Stationary phase

검색결과 775건 처리시간 0.025초

WELL-BALANCED ROE-TYPE NUMERICAL SCHEME FOR A MODEL OF TWO-PHASE COMPRESSIBLE FLOWS

  • Thanh, Mai Duc
    • 대한수학회지
    • /
    • 제51권1호
    • /
    • pp.163-187
    • /
    • 2014
  • We present a multi-stage Roe-type numerical scheme for a model of two-phase flows arisen from the modeling of deflagration-to-detonation transition in granular materials. The first stage in the construction of the scheme computes the volume fraction at every time step. The second stage deals with the nonconservative terms in the governing equations which produces states on both side of the contact wave at each node. In the third stage, a Roe matrix for the two-phase is used to apply on the states obtained from the second stage. This scheme is shown to capture stationary waves and preserves the positivity of the volume fractions. Finally, we present numerical tests which all indicate that the proposed scheme can give very good approximations to the exact solution.

이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구 (The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.

단상 인버터 시스템에서 영 전압 근처 전압 강하 검출 기법에 관한 연구 (The Study on Sag Detecting Scheme around Zero Crossing Voltage for Single-Phase Inverter System)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제28권1호
    • /
    • pp.96-104
    • /
    • 2014
  • The all pass filter generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the virtual q-axis voltage cannot detect the voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage between the current and previous value around the zero crossing voltage is not enough to detect the voltage sag. Therefore, the new detection scheme which can detect the sag around the zero crossing voltage is proposed.

Optical Resolution of Dansyl Amino Acids with Addition of Benzyl-L-Hydroxyproline Copper(II) Chelate by High Performance Liquid Chromatography

  • Sun Haing Lee;Tae Sub Oh;Sang Hyun Bak
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권6호
    • /
    • pp.491-495
    • /
    • 1989
  • Resolution of enantiomers of DNS-amino acids has been achieved by a reversed phase liquid chromatography with an addition of a copper(Ⅱ) complex of N-benzyl-L-hydroxyproline to the mobile phase. N-Benzyl-L-hydroxyproline was prepared and used as a chiral ligand of copper(Ⅱ) chelate for the optical resolution. The pH and the concentration of copper(Ⅱ) chelate, organic solvent, and buffer agent in the mobile phase all affect the optical resolutions of dansyl amino acids. The elution orders between D and L-DNS-amino acids were different depending on the structure of the side chain of the amino acids. The retention mechanism for the chiral separation of the dansyl amino acids can be illustrated by the equilibrium of ligand exchange and by hydrophobic interaction with $C_{18}$ stationary phase. The chiral separation can be illustrated with cis and trans effect of the ligand exchange reaction.

Problem-solving approach for salbutamol analysis by HPLC during pharmaceutical assay

  • Gholizadeh-Hashjin, Aiesheh;Hamishehkar, Hamed;Monajjemzadeh, Farnaz
    • 분석과학
    • /
    • 제35권5호
    • /
    • pp.189-196
    • /
    • 2022
  • When cationic basic compounds are chromatographed using hydro-organic mobile phase, the presence of anionic free silanols in the silica-based stationary phases results in broad and asymmetrical peaks. The addition of an ionic reagent to the mobile phase prevents analytes from accessing free silanols, improving peak shape. In this study, the chromatographic behavior of salbutamol sulfate as a basic compound was investigated under various conditions, including the use of different columns, mobile phases, and ion-pair reagents such as triethanolamine (TEA) and sodium heptane sulfonate (SHS). The retention and peak shape of chromatograms were both evaluated. The results show that pre-conditioning the column with TEA and including it in the mobile phase can prevent cationic analytes from accessing anionic silanols, resulting in improved peak shape. Furthermore, buffering the mobile phase is an important factor in keeping the pH constant throughout the process. The chosen method was validated in part. This study could be helpful for researchers and analyst to solve such problems with cationic basic components.

Image Authentication Using Only Partial Phase Information from a Double-Random-Phase-Encrypted Image in the Fresnel Domain

  • Zheng, Jiecai;Li, Xueqing
    • Journal of the Optical Society of Korea
    • /
    • 제19권3호
    • /
    • pp.241-247
    • /
    • 2015
  • The double-random phase encryption (DRPE) algorithm is a robust technique for image encryption, due to its high speed and encoding a primary image to stationary white noise. Recently it was reported that DRPE in the Fresnel domain can achieve a better avalanche effect than that in Fourier domain, which means DRPE in the Fresnel domain is much safer, to some extent. Consequently, a method based on DRPE in the Fresnel domain would be a good choice. In this paper we present an image-authentication method which uses only partial phase information from a double-random-phase-encrypted image in the Fresnel domain. In this method, only part of the phase information of an image encrypted with DRPE in the Fresnel domain needs to be kept, while other information like amplitude values can be eliminated. Then, with the correct phase keys (we do not consider wavelength and distance as keys here) and a nonlinear correlation algorithm, the encrypted image can be authenticated. Experimental results demonstrate that the encrypted images can be successfully authenticated with this partial phase plus nonlinear correlation technique.

Helicobacter pylori에서 metronidazole 내성이 미치는 생물학적 영향 (Biological Effect of Metronidazole Resistance in Helicobacter Pylori)

  • 이진혁;이선미;남원희;김은실;김진호;강호영;정진용
    • 생명과학회지
    • /
    • 제15권6호
    • /
    • pp.955-960
    • /
    • 2005
  • 메트로니다졸은 인체 위장질환의 원인균인 헬리코박터 파일로리를 박별하기위해 처방하는 주요 약제이다 그러나 인체로부터 분리한 헬리코박터 파일로리 균주는 메트로니다졸에 내성을 가지는 경우가 일반적이며, 이러한 내성원인은 이 균주의 염색체 상에 존재하는 두 종류의 nitroreductase 유전자인 rdxA와frxA 유전자가 비활성화됨에 따라 유발된다. 본 연구에서는 헬리코박터 파일로리 균에서 rdxA 유전자에 변이를 도입하여 메트로니다졸에 내성을 가지는 균주를 구축하여, 메트로니다졸 내성이 균주에 미치는 생물학적 영향을 관찰하고자 하였다. In vitro상에서 메트로니다졸 내성균주는 대조균과 비교하여 exponential phase에서는 거의 차이 없이 증식하였으나 stationary phase에서는 빠르게 생육활성을 잃는 것을 관찰할 수 있었다. 또한 생쥐를 이용한 동물 실험에서 메트로니다졸 내성균주는 생쥐의 위장 내에서 서식하는 능력을 상실함을 알 수 있었다. 그러나 이러한 생육 활성을 회복시켜주는 compensate템 mutation을 가진 균주를 쉽게 얻을 수 있었으며 이 균주는 생쥐에 감염시키면 위장 내에서 서식하는 능력을 회복함을 알 수 있었다.

dq 정지, 동페 좌표계를 이용한 순간전압강하 보상 (Voltage Sag Compensation using dq Stationary and Synchronous Rotating Frame)

  • 이교성;이용제;박정균;최현영;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.973-975
    • /
    • 2002
  • Voltage Sags are the short-duration reductions in rms voltage caused by faults in the electric supply system and the starting of large loads, such as motors. In this paper, we use the dq transformation(dq stationary frame and dq synchronous rotating frame) for series voltage sag compensation algorithm. Analysis, simulation results are presented for voltage sags on a three-phase balanced voltage source.

  • PDF

2-D 웨이브릿 변환을 이용한 해양 탄성파탐사 자료의 잡음 감쇠 (Noise Attenuation of Marine Seismic Data with a 2-D Wavelet Transform)

  • 김진후;김성보;김현도;김찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1309-1314
    • /
    • 2008
  • Seismic data is often contaminated with high-energy, spatially aliased noise, which has proven impractical to attenuate using Fourier techniques. Wavelet filtering, however, has proven capable of attacking several types of localized noise simultaneously regardless of their frequencies. In this study a 2-D stationary wavelet transform is used to decompose seismic data into its wavelet components. A threshold is applied to these coefficients to attenuate high amplitude noise, followed by an inverse transform to reconstruct the seismic trace. The stationary wavelet transform minimizes the phase-shift errors induced by thresholding that occur when the conventional discrete wavelet transform is used.

3상 PWM Converter를 위한 정지 좌표계법 Analog 제어기 설계 및 시뮬레이션 (Design and Simulation of analog controller for 3 Phase PWM Converter Based on Stationary Reference Frame)

  • 이영국;노철원;최종률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.14-20
    • /
    • 1997
  • Due to several advantages of Pulse Width Modulated(PWM) Converter, such as unity power factor with low-harmonics and energy regeneration, PWM converter has been widely used in industrial application. In every application of energy conversion equipment, the design and implementation must be carried out considering performance and cost. High quality with low cost is the best choice for energy conversion equipment. High dc link voltage can reduce inverter and motor side losses and system dimension compare to low dc link voltage. Analog controller can make PWM converter cheaper without considerable degradation of the performance than digital controller. This paper shows the simplified analog controller-for 600V dc link voltage using stationary reference frame control and the simulation results.

  • PDF