• Title/Summary/Keyword: Static shear loading

Search Result 256, Processing Time 0.023 seconds

Perforated shear connectors

  • Machacek, Josef;Studnicka, Jiri
    • Steel and Composite Structures
    • /
    • v.2 no.1
    • /
    • pp.51-66
    • /
    • 2002
  • Perforated shear connectors currently used in composite steel and concrete structures are described and evaluated. Modifications of the perforated connector suitable for common use injavascript:confirm_mark('abe', '1'); civil and bridge engineering are proposed. The connectors were tested in laboratories of CTU Prague for shear load capacity. Push tests of connectors with 32 mm openings and with 60 mm openings, both in normal and lightweight concrete of different strength characteristics and with different transverse reinforcement, were carried out. The experimental study also dealt with the connector height and parallel arrangement of two connectors and their influence on shear resistance. While extensive tests with static loading were carried out, fatigue tests under repeated loading are still in progress. After statistical evaluation of the experimental results and comparisons with other available data the authors developed reasonable shear resistance formulas for all proposed arrangements.

Behavior of Fatigue Crack Initiation and Growth in SM45C Steel under Biaxial Loading (이축하중을 받는 SM45C강의 피로균열의 발생과 성장거동)

  • KIM SANG-TAE;PARK SUN-HONG;KWUN SOOK-IN
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.6 s.61
    • /
    • pp.84-90
    • /
    • 2004
  • Fatigue tests were conducted on SM45C steel using hour-glass shaped smooth tubular specimen under biaxial loading in order to investigate the crack formation and growth at room temperature. Three types of loading systems, were employed fully-reserved cyclic torsion without a superimposed static tension or compression fully-reserved cyclic torsion with a superimposed static tension and fully-reserved cyclic torsion with a superimposed static compression. The test results showed that a superimposed static tensile mean stress reduced fatigue life however a superimposed static compressive mean stress increased fatigue life. Experimental results indicated that cracks were initiated on planes of maximum shear strain whether or not the mean stresses were superimposed. A biaxial mean stress had an effect on the direction that the cracks nucleated and propagated at stage 1 (mode II).

Static Experiment for the Seismic Performance of a 2 Story RC Shear Wall System (2층 RC 전단벽식 구조물의 내진성능에 대한 정적 실험)

  • Lee, Sang-Ho;Oh, Sang-Hoon;Hwang, Won-Tae;Lee, Kyung-Bo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.55-65
    • /
    • 2010
  • The purpose of this experimental study is to evaluate the seismic performance of a 2 story RC shear wall system by the static reversal loading test. The lower 2 stories of the prototype structure were selected, and the specimens of this study were comprised of a T-type wall with an opening. The specimens were reduced to about 60% of the full scale size and were constructed to measure the result of the experimental variable regarding the existence of a lintel beam. To perform this study, the static repeated loading test was performed. According to the existence or absence of a lintel beam, the structural capacities and behavioral differences of the shear wall system were compared. The test results of this study showed that the specimen with a lintel beam underwent the seismic performance with an ultimate strength and ductility capacity better than the specimen without a lintel beam.

A numerical approach for simulating the behaviour of timber shear walls

  • Loo, Wei Yuen;Quenneville, Pierre;Chouw, Nawawi
    • Structural Engineering and Mechanics
    • /
    • v.42 no.3
    • /
    • pp.383-407
    • /
    • 2012
  • A numerical approach to simulate the behaviour of timber shear walls under both static and dynamic loading is proposed. Because the behaviour of timber shear walls hinges on the behaviour of the nail connections, the force-displacement behaviour of sheathing-to-framing nail connections are first determined and then used to define the hysteretic properties of finite elements representing these connections. The model nails are subsequently implemented into model walls. The model walls are verified using experimental results for both monotonic and cyclic loading. It is demonstrated that the complex hysteretic behaviour of timber shear walls can be reasonably represented using model shear walls in which nonlinear material failure is concentrated only at the sheathing-to-framing nail connections.

Static and Repeat Loads Model Test on Soft Clay Layer due to the Geotextile Reinforcement (토목섬유로 보강된 연약지반의 정.동적 모형실험)

  • Kim, Young-Su;Kwon, Sung-Mok;Kim, Yeun-Wook;Kim, Hyoung-Jun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.232-239
    • /
    • 2005
  • Recently geosynthetics that can be constructed on soft ground have been used for reinforcement and separation in various ways. Through laboratory model tests and numerical analysis, in this study, estimated the suitability of cable elements and appropriate input factors considering loading effect in modeling of geosynthetics. First, in laboratory model tests, geosynthetics were constructed on the clay, and covered with the thickness, 7.5cm of sand mat. And then static and dynamic model tests were performed measuring loading, settlement, ground lateral displacement, and displacements of geosynthetics, but, for cyclic loading, bearing capacity increased linearly with stiff slop because cyclic loading with constant cyclic pressure compacted the ground. Numerical analysis were performed with FLAC 4.0 2D using Mohr-Coulomb and Modified Cam-Clay models, and they compared with the results of model tests. Cable elements of FLAC in modeling geosynthetics couldn't consider the characteristics of geosynthetics that increase shear strength between geosynthetics and clay according to the loading increase. Therefore, in this study, appropriate equation that can consider loading effects in Cable elements was proposed by Case Study.

  • PDF

Parametric resonance of composite skew plate under non-uniform in-plane loading

  • Kumar, Rajesh;Kumar, Abhinav;Panda, Sarat Kumar
    • Structural Engineering and Mechanics
    • /
    • v.55 no.2
    • /
    • pp.435-459
    • /
    • 2015
  • Parametric resonance of shear deformable composite skew plates subjected to non-uniform (parabolic) and linearly varying periodic edge loading is studied for different boundary conditions. The skew plate structural model is based on higher order shear deformation theory (HSDT), which accurately predicts the numerical results for thick skew plate. The total energy functional is derived for the skew plates from total potential energy and kinetic energy of the plate. The strain energy which is the part of total potential energy contains membrane energy, bending energy, additional bending energy due to additional change in curvature and shear energy due to shear deformation, respectively. The total energy functional is solved using Rayleigh-Ritz method in conjunction with boundary characteristics orthonormal polynomials (BCOPs) functions. The orthonormal polynomials are generated for unit square domain using Gram-Schmidt orthogonalization process. Bolotin method is followed to obtain the boundaries of parametric resonance region with higher order approximation. These boundaries are traced by the periodic solution of Mathieu-Hill equations with period T and 2T. Effect of various parameters like skew angle, span-to-thickness ratio, aspect ratio, boundary conditions, static load factor on parametric resonance of skew plate have been investigated. The investigation also includes influence of different types of linearly varying loading and parabolically varying bi-axial loading.

Protocol for testing of cold-formed steel wall in regions of low-moderate seismicity

  • Shahi, Rojit;Lam, Nelson;Gad, Emad;Wilson, John
    • Earthquakes and Structures
    • /
    • v.4 no.6
    • /
    • pp.629-647
    • /
    • 2013
  • Loading protocols have been developed for quasi-static cyclic testing of structures and components. However, it is uncertain if protocols developed for conditions of intense ground shaking in regions of high seismicity would also be applicable to regions of low-moderate seismicity that are remote from the tectonic plate boundaries. This study presents a methodology for developing a quasi-static cyclic displacement loading protocol for experimental bracing evaluation of cold-formed steel stud shear walls. Simulations presented in the paper were based on conditions of moderate ground shaking (in Australia). The methodologies presented are generic in nature and can be applied to other regions of similar seismicity conditions (which include many parts of China, Korea, India and Malaysia). Numerous response time histories including both linear and nonlinear analyses have been generated for selected earthquake scenarios and site classes. Rain-flow cycle counting method has been used for determining the number of cycles at various ranges of normalized displacement amplitude. It is found that the number of displacement cycles of the loading protocol increases with increasing intensity of ground shaking (associated with a longer return period).

Experimental Study on Seismic Resistance of A Unreinforced Cement Brick Building (비보강 시멘트벽돌 건물의 내진성능 실험연구)

  • 김장훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.298-307
    • /
    • 2000
  • The behavior of a unreinforced cement brick building structure subjected to earthquake loading was experimentally investigated. for this four full size wall specimens were tested under quasi-static in-plane cyclic loading. Experimental observations indicate that the failure modes of unreinforced masonry walls are principally governed by sliding or/and rocking depending on the aspect ration and magnitude of axial loading. Also found was the flexure or shear mode resulting from the degraded strength of brick and/or mortar due to the cyclic loading effect.

  • PDF

The Effect of Out-of-Plane Load on the In-Plane Shear Capacity of Reinforcement Concrete Shear Wall (철근 콘크리트 전단벽에서 면외 하중이 면내 전단성능에 미치는 영향)

  • Shin, Hye Min;Park, Jun Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.77-83
    • /
    • 2024
  • The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.

Experimental study on hybrid FRP-steel RC shear wall with replaceable dampers

  • Shiying Xiao;Mengfu Wang
    • Steel and Composite Structures
    • /
    • v.52 no.2
    • /
    • pp.217-236
    • /
    • 2024
  • The objective of this paper was to discuss the seismic performance of hybrid FRP-steel reinforced concrete shear wall with replaceable friction dampers at the feet of the wall. The hysteretic characteristics of five wall specimens were studied by pseudo-static loading tests. The results showed that the damage of the specimens was concentrated on the friction dampers, and the energy consumption capacity was increased while making up for the defect of low ductility of FRP reinforced wall specimens. And the repairability of the wall after earthquake was improved. Finally, a calculation method of initial stiffness of shear wall with replaceable dampers was proposed.