• Title/Summary/Keyword: Static image

Search Result 424, Processing Time 0.036 seconds

Image Processing Technique for Measuring the Static Displacement of Bridges from General Inspection Photograph (일반 점검사진에서 교량의 정적 변위 추출을 위한 영상처리기법)

  • Cho, Jun Sang;Huh, Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.173-180
    • /
    • 2011
  • This paper aims to propose an image processing technique for measuring the static displacement of bridges from general inspection photograph; the color, shape, and spatial transformations of an arbitrary image stored in bridge management system database are used. This study is verified by using numerical analyses with experiments; the results demonstrate that the static displacement of bridges are measured by proposed technique. Moreover, this technique is able to obtain the static structural response of the bridge with changes in temperatures.

Realization of Static Image on OLEO using Photoluminescence Degradation (PL Degradation을 활용한 OLED 소자의 사진 이미지 구현)

  • Suh, Won-Gyu;Moon, Dae-Gyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.859-862
    • /
    • 2008
  • We have realized static image on organic light emitting diodes (OLEDs) using photoluminescence degradation. Ultraviolet (UV) was irradiated to the glass side of device. UV power was 350 Wand the wavelength was 365 nm. The UV irradiation gives rise to the degradation of photoluminescence. Due to the degradation, the current density-voltage curve was shifted to the higher voltage side and the luminescence was also degraded by the current and photoluminescence drop. The negative imaged films were prepared to control the transmittance of UV. The UV light was passed through the film. By this method, the film image was transferred to the device with reversed image and the static image was realized on the OLED.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

Mixing Characteristics of Static Mixers for Emulsion Oil (이멀션유 정적믹서의 혼합특성 연구)

  • 김기성;박상규
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.91-98
    • /
    • 2000
  • The fuels of water-in-oil emulsion have a potential of reducing PM(Particulate Matter) and NOx emissions, and increassing combustion efficiency in the furnaces and the burners. For making the most of the beneficial of the secondary atomization due to the microexplosion, the water droplets distributed in the oil must have the optimal sizes. The purpose of this paper is to investigate the water droplet size distribution characteristics of the different types of the static mixers. For analysing the size distribution characteristics efficiently, image analysis system was constructed and an appropriate image processing algorithm was developed. Two kinds of static mixers: Kenics type and RF type, were tested. As a results, RF type static mixer shows a better characteristics in the mean drop sizes, particularly in the condition of high water content.

  • PDF

Development of Radial Fin Static Mixers for Emulsion Oil (이멀션유용 방사상 핀 정적믹서 개발)

  • 김기성;박상규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.904-911
    • /
    • 2001
  • The fuels of water-in-oil emulsion have a potential of reducing PM(Particulate Matter) and NOx emissions, and increasing combustion efficiency in the furnaces and the burners. For making the most of the beneficial of the secondary atomization due to the microexplosion, the water droplets distributed in the oil must have the optimal sizes. The purpose of this paper is to investigate the water droplet size distribution characteristics of the different types of the static mixers. For analysis the size distribution characteristics efficiently, image analysis system wes constructed and an appropriate image processing algorithm was developed. Two kinds of static mixers: Kenics type and RF type, were tested. As a results, RF type static mixer shows a better characteristics in the mean drop size, particularly in the condition of high water content.

  • PDF

A STATIC IMAGE RECONSTRUCTION ALGORITHM IN ELECTRICAL IMPEDANCE TOMOGRAPHY (임피던스 단층촬영기의 정적 영상 복원 알고리즘)

  • Woo, Eung-Je;Webster, John G.;Tompkins, Willis J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.5-7
    • /
    • 1991
  • We have developed an efficient and robust image reconstruction algorithm for static impedance imaging. This improved Newton-Raphson method produced more accurate images by reducing the undesirable effects of the ill-conditioned Hessian matrix. We found that our electrical impedance tomography (EIT) system could produce two-dimensional static images from a physical phantom with 7% spatial resolution at the center and 5% at the periphery. Static EIT image reconstruction requires a large amount of computation. In order to overcome the limitations on reducing the computation time by algorithmic approaches, we implemented the improved Newton-Raphson algorithm on a parallel computer system and showed that the parallel computation could reduce the computation time from hours to minutes.

  • PDF

Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration (영상처리를 이용한 정동적 변위 계측과 속도, 가속도 추산방식 연구)

  • Heo, Seok;Kwak, Moon-Kyu;Lee, Ho-Bum
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.527-532
    • /
    • 2010
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, ccd image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration measurement, velocity and acceleration directly without any contact. The current resolution of the displacement measurement is limited to 1/100 millimeter scale.

  • PDF

Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration (영상처리를 이용한 정적·동적 변위 계측과 속도·가속도 추산방식 연구)

  • Heo, Seok;Lee, Bum-Ho;Jang, Il-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.2
    • /
    • pp.112-119
    • /
    • 2011
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, CCD(charge coupled device) image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration displacement, velocity and acceleration directly without any contact. The current resolution for the displacement measurement can be seen from the results.

A study on the Image Edge Enhancement Detection of the Hybrid FCNN using the Morphological Operations (형태학 연산자를 이용한 하이브리드 FCNN의 영상 에지 고양 검출에 관한 연구)

  • 홍연희;변오성;조수형;문성룡
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1025-1028
    • /
    • 1999
  • After detecting the edge which is applying the morphological operators to the hybrid FCNN, we could analyze and compare. The hybrid FCNN is completely removed to the noise in the image, and worked in order to obtain the result image which is closest to the original image. Also, the morphological operator is applied to the image as the method in order to detect more good the edge than the conventional edge. FCNN which is the pipeline type is completely suitable to detecting the image processing as well as the hardware size. In this paper. we would make the structure elements of the morphological operator the variable template and the static template, and compare with the edge enhancement of two images. After being the result which is applying the variable template morphological operator and the static template morphological operator to the image, we could know that the edge images applying the variable template is superior in a edge enhancement side.

  • PDF

The Role of Corporate Image and Brand Personality in Global Consumer Choice: An Empirical Exploration

  • Lee, Bong-Soo
    • Journal of Korea Trade
    • /
    • v.25 no.2
    • /
    • pp.178-195
    • /
    • 2021
  • Purpose - This study aims to analyze consumer in the multidimensional aspect of a combination of corporate image and brand personality in order to identify the structural causal relationship between consumer choice and corporate image and brand personality. Design/methodology - This study combined theoretical literature studies with empirical field studies using questionnaire survey methods. To achieve this objective, a hypothetical causal model consisting of three potential variables and nine measurement variables was created based on prior research, and a structural equation model was used to identify the suitability of the model. Findings - The hypothetical model established by this study was judged to be generally appropriate. In particular, corporate image was shown to have significant static direct effects on consumer choice and brand personality. It was also shown that brand personality had a direct static effect on consumer choice, and that corporate image has an indirect significant impact on consumer choice by moderating brand personality. Originality/value - Previous papers have mainly focused on one-dimensional studies of various images, such as companies and brands. However, this paper used a model that analyzed consumer choice through multi-clue information rather than corporate images as the only clue to consumer choice.