• 제목/요약/키워드: Static alignment

검색결과 76건 처리시간 0.022초

정적 자세에서 하지정렬 측정방법에 관한 고찰 (Measurement Methods of Lower Extremity Alignment in Static Posture)

  • 공희경;조현래;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2003
  • We need to study about lower extremity alignment because the structure dictates the function of lower extremity. Through lower extremity alignment assessment in static posture, we recognize abnormal structural conditions which could affect dynamic motion such as gait. To evaluate of lower extremity alignment provide so many useful information, but method of measurement is so limited. Therefore, this review will assist understanding for measurement of lower extremity alignment in static posture. From now on study about the objective measurement method must be achieved much more in physical therapy.

  • PDF

하지정렬의 임상적 측정방법에 대한 분석 (Analysis of Clinical Measurement Methods of Lower Extremity Alignment)

  • 공희경;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제16권2호
    • /
    • pp.17-21
    • /
    • 2004
  • We need to study about lower extremity alignment because the structure dictates the function of lower extremity. Through lower extremity alignment assessment in static posture, we recognize abnormal structural conditions which could affect dynamic motion such as gait. To evaluate of lower extremity alignment provide so many useful information, but method of measurement is so limited. Therefore, this review will assist understanding for measurement of lower extremity alignment in static posture. From now on study about the objective measurement method must be achieved much more in physical therapy.

  • PDF

힘측정판과 레이저 광을 이용한 정적 의족정렬장치의 개발 (Development of a Static Prosthesis-Alignment Device Using a Force Plate and a Laser Light)

  • 이기원;김기완;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권4호
    • /
    • pp.385-390
    • /
    • 2000
  • 의족착용자의 보행에 있어서 의족의 정렬은 매우 중요하나, 정량적이고 다양한 의족에 공통적으로 적용할 수 있는 정렬방법이 아직 소개되지 않고 있다. 본 연구를 통해서 load cell, 레이저, 이송 가이드로 구성되는 정적 의족정렬시스템을 개발되었다. 개발된 시스템을 24명의 남자성인과 4명의 하퇴의족착용자에게 적용하여 직립자세와 전방, 후방ㅇ로 기운 자세에서 족관절, 슬관절, 대전자, 어깨관절등과 하중선과의 상대적 위치를 측정하였다. 정상인의 중립자세에서 하중선의 위치는 외과, 슬관절, 견관절에서는 앞쪽에 그러나 대전자에서는 뒤쪽에 있었다. 정상인이 앞쪽으로 최대한 기운 자세에서 외과와 슬관절, 대전자는 하중선의 뒤쪽에 위치하였으나 견관절은 앞쪽에 위치하였다. 그러나 뒤쪽으로 기운 자세의 경우, 하중선은 견관절을 제외한 모든 곳의 뒤쪽에 위치하였다. 의족착용자의 환측의 하중선은 족관절, 슬관절, 대전자, 견관절 모두의 전방에 위치하였으며, 의족착용자의 건측에서의 하중선의 위치는 정상인의 경우와 통계적으로 유사하였다. 본 연구를 통해서 개발된 정적 의족정렬시스템은 의족 착용자는 물론, 정상인들의 하중선과 주요 관절과의 상대적 위치를 파악하는데 매우 유용하게 사용될 수 있을 것으로 기대된다.

  • PDF

Best-Effort Interference Alignment for K Users Quasi-Static MIMO Interference Channels

  • Jiang, Lijing;Song, Rongfang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권6호
    • /
    • pp.2859-2872
    • /
    • 2019
  • Interference alignment (IA) has been a powerful approach to achieve the maximum degree of freedom (DoF) for K users multiple-input-multiple-output (MIMO) interference channels. However, due to the feasibility constraint, aligning all the interference signals at each receiver is impractical for large K without symbol extension. In this paper, we propose two best-effort interference alignment (BEIA) schemes that the network selects the maximum number of interfering transmitters to align their signals given the feasibility conditions when each transmitter-receiver pair has a constant number of data streams. Besides, in case of not all interfering signals aligned at each receiver, an upper bound of the average throughput is derived. Simulation results show that the proposed schemes have superiority over the traditional methods, such as time division multiple access (TDMA) and cluster IA(CIA), in low and moderate signal-to-noise ratio (SNR) region in terms of average user throughput. In addition, the proposed max-min relative interference distance alignment scheme outperforms the proposed scheme of equal interfering transmitters number alignment in terms of both average user throughput and minimum user throughput.

포배열카메라 영상을 활용한 함포 사격통제시스템의 동적배열오차 분석 및 보정방법 (Study on Analyzing and Correction of Dynamic Battery Alignment Error in Naval Gun Fire Control System by using Image of Boresight Telescope)

  • 김의진;서태일
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.745-751
    • /
    • 2013
  • In naval gun firing, firing accuracy comes from the combination of each component's accuracy in CFCS (Command and Fire Control System) like tracking sensors and gun. Generally, battery alignment is done to correct the error between gun and tracking sensor by using boresight telescope on harbor and sea. But normally, the battery alignment can compensate only the static alignment error and ignore dynamic alignment error which is caused by own ship movement. There was no research on this dynamic alignment error until now. We propose a new way to analyze dynamic arrangement error by using image of boresight telescope. In case of the dynamic alignment error was due to time delay of own ship attitude information, we propose the way to compensate it.

Vacuum 'brusher' for the alignment treatment of the large area LCD sub strates

  • Yaroshchuk, O.V.;Liu, P.C.;Lee, C.D.;Lee, C.Y.;Kravchuk, R.M.;Dobrovolskyy, A.M.;Protsenko, I.M.;Goncharov, A.A.;Lavrentovich, O.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.768-773
    • /
    • 2005
  • We present an overview of our new method of liquid crystal (LC) alignment based on the anisotropic etching of the alignment layers with a directed plasma flux. The method is realized by the use of anode layer source of "race track" geometry generating two "sheets" of accelerated plasma. These sheets are directed obliquely to the treated substrates. The static and dynamic irradiation regimes have been explored. The optimized processing conditions and materials are discussed. The technique yields an excellent uniformity of liquid crystal alignment of planar, tilted and vertical types. It is shown that the new method can be easily adapted for the alignment treatment of large area substrates used in the modern LCD manufacturing process.

  • PDF

항공기의 생존성과 센서 정렬의 기술 분석 (Aircraft Survivability and Sensors Alignment Techniques)

  • 강자영;이상철;전갑송;문성철;서석훈;이창재
    • 한국항공운항학회지
    • /
    • 제16권1호
    • /
    • pp.29-36
    • /
    • 2008
  • The vulnerability of aircraft, especially rotary wing aircraft, has been an ongoing issue since their advent in combat operations during the 1940s. In this paper, representative sensors for survivability of those aircraft in modern battlefield are surveyed and top level requirements and parameters are defined. Also problems of multi-sensor alignment on modern agile and flexible platform are discussed and several techniques such as static alignment and transfer alignment are introduced.

  • PDF

Effects of Knee Malalignment on Static and Dynamic Postural Stability

  • Chae, Yun-Won;Park, Ji-Won;Park, Seol
    • The Journal of Korean Physical Therapy
    • /
    • 제27권1호
    • /
    • pp.7-11
    • /
    • 2015
  • Purpose: This study was conducted in order to determine the effects of knee malalignment including genu varum, valgum, and recurvatum on static and dynamic postural stability. Methods: A total of 80 subjects were enrolled in this study. Subjects who showed over 3 cm in the distance between the knees were classified as the genu varum group, and subjects who showed over 3 cm in the distance between the ankles were classified as the genu valgum group. Subjects who showed over 1 cm in the distance between the patella and a table in prone position were classified as the genu recurvatum group. Static and dynamic stability were measured as overall, anterioposterior, and mediolateral balance index using a Biodex Balance System. Results: This study showed that knee alignment affected static and dynamic postural stability. In particular, there were significant differences in the mediolateral stability index among genu varum, valgum group, and the other groups, but no differences in overall and anteriolateral stability index. Significant differences in the anterioposterior stability index were observed between genu recurvatum and the other groups, however, there were no differences in overall and mediolateral stability index. Conclusion: The findings were that knee malalignment affects postural stability toward a specific direction. Treatment to improve postural stability for treatment of knee malalignment or to prevent falling or injuries is needed and postural stability toward a specific direction according to the knee alignment conditions should be considered.

초대형 콘테이너선의 축계정렬 계산 사례 소개 (The Introduction of Shaft Alignment Calculation for very Large Container Vessel)

  • 강동춘;박건우;김경호
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2005년도 특별논문집
    • /
    • pp.138-143
    • /
    • 2005
  • Recently, it is much more required to approach the accurate shaft alignment analysis according to the tendency of active showing in large container vessel and that of the heavy weight of propeller in connection with it. Shaft alignment calculation lies upon how the pressure apply on bearings properly in operation of main engine and how the stress of shaft puts within that of limit of bearing material and how the movement of shaft is prospected owing to propeller forces and moments. Therefore, we have conducted the shaft alignment calculation of very large container vessel considering the deformation of hull structure and the propeller forces and moments and the static and dynamic condition of shaft. The calculation results show the pressure distribution of aft bush and the movement of shaft in bearing. The shaft alignment calculation helps the stable application of shaft alignment, which was proved in sea trial.

  • PDF

8주간 닫힌 사슬형 필라테스 운동이 하지 정렬에 미치는 영향 (Effect of an 8-week Closed Kinetic Chain Styled Pilates Exercise on Lower Limb Alignment)

  • Ga Ram Jeon;Sukhoon Yoon
    • 한국운동역학회지
    • /
    • 제33권4호
    • /
    • pp.128-136
    • /
    • 2023
  • Objective: The aim of this study was to investigate the effect of an 8-week closed kinetic chain typed Reformer and Chair Pilates exercise on static and dynamic lower limb alignment for healthy female adults. Method: Ten healthy young female adults without musculoskeletal injury history in last 6 months (Age: 29.3 ± 3.5 yrs., Height: 165 ± 3.4 cm, Body mass: 58.2 ± 5.4 kg) participated in this study. All participants asked to join the 8-week closed kinetic chain typed Reformer and Chair Pilates exercise, and the program was conducted for 60 minutes twice a week. Participants were asked to be measure a static Q-angle and performed free squat one week before and after the program. A 3-D motion analysis with 8 infrared cameras and 5 channels of EMG was executed in this study. The effectiveness of the training was evaluated by paired t-test, and the significance level was set at .05. Results: A significantly decreased in internal rotation angles was found at hip joint during free squat after the training. Also, significantly decreased in lateral rotation angles were found at knee and ankle joint during free squat after training. Finally, significantly decreased in muscle activations were found at adductor longus and peroneus longus during free squat after training. Conclusion: From results of our study, it is concluded that an 8-week closed kinetic chain typed Pilates exercise positively effect on lower limb alignment during dynamic movement.