• Title/Summary/Keyword: Static Test

Search Result 3,282, Processing Time 0.044 seconds

A Study on Blood Stasis Pattern for 159 Hysterectomy Patients (자궁절제술 시행 환자 159명의 어혈증 연구)

  • Choi, Jin-Young;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.4
    • /
    • pp.122-134
    • /
    • 2009
  • Purpose: The purpose of this study is to know the blood stasis pattern for the patients who had hysterectomy. Methods: Among the patients who had hysterectomy in the department of obstetrics and gynecology, OO medical center from March 3rd 2009 to October 21st 2009, subjects who met inclusion criteria and submitted appropriate questionnaire. We compared blood stasis score and operational method, age, BMI, past operation history of abdominal and pelvic site, parity, whether adhesiolysis, oriental medicine intervention was done. For statistics, we used independent samples t-test, oneway analysis of variances(ANOVA) and SPSS version 13.0 for windows. Results: Blood stasis score of the subtotal hysterectomy group ($44.43{\pm}15.01$) is higher than that of the total hysterectomy group($39.04{\pm}12.46$). Blood stasis score under the age 40($51.88{\pm}12.68$) is higher than 40-49 age patients($40.34{\pm}14.24$) and over the age 50 patients($41.62{\pm}13.46$). There is no statistically significant difference between laparoscopic and abdominal trial, whether adhesiolysis, oriental medicine intervention was done, BMI, past operation history abdominal and pelvic site, parity, chief complaint before hysterectomy, oriental medicine intervention. Conclusion: Through the results showed, when traditional Korean medical doctors use static blood medication, history of hysterectomy and age should be considered as the history of subtotal hysterectomy and younger age tend to have a higher rate of a blood stasis pattern. We need a further study to develop blood stasis indicators with a validated questionnaire, and more subjects involved at multiple institutions.

Study of the Static Shear Behaviors of Artificial Jointed Rock Specimens Utilizing a Compact CNS Shear Box (Compact CNS shear box를 활용한 모의 절리암석시료의 정적 전단 거동에 관한 연구)

  • Hanlim Kim;Gyeongjo Min;Gyeonggyu Kim;Youngjun Kim;Kyungjae Yun;Jusuk Yang;Sangho Bae;Sangho Cho
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.574-593
    • /
    • 2023
  • In this study, the effectiveness and applicability of a newly designed Compact CNS shear box for conducting direct shear tests on jointed rock specimens were investigated. CNS joint shear tests were conducted on jointed rocks with Artificially generated roughness while varying the fracture surface roughness coefficient and initial normal stress conditions. In addition, displacement data were validated by Digital image correlation analysis, fracture patterns were observed, and comparative analysis was conducted with previously studied shear behavior prediction models. Furthermore, the accuracy of the displacement data was confirmed through DIC analysis, the fracture patterns were observed, and the shear properties obtained from the tests were compared with existing models that predict shear behavior. The findings exhibited a strong correlation with specific established empirical models for predicting shear behavior. Furthermore, the potential linkage between the characteristics of shear behavior and fracture patterns was deliberated. In conclusion, the CNS shear box was shown to be applicable and effective in providing data on the shear characteristics of the joint.

Estimation of a 9.77 G/T Small Fishing Vessel's Operating Performance Depending on Forward Speed Based on 3-DoF Captive Model Tests (9.77톤급 소형어선의 3자유도 구속모형시험을 통한 선속 별 운항성능 추정)

  • Dong-Jin Kim;Haeseong Ahn;Kyunghee Cho;Dong Jin Yeo
    • Journal of Navigation and Port Research
    • /
    • v.47 no.6
    • /
    • pp.305-314
    • /
    • 2023
  • In this study, a mathematical model of a 9.77 G/T small fishing vessel was established based on captive model tests. The powering and manoeuvring performances of the vessel in the harbor and coastal sea were focused on, so captive model tests were conducted up to the full-scale speed of 8 knots. Propeller open water, resistance, and self-propulsion tests of a 1/3.5-scaled model ship were performed in a towing tank, and the full-scale powering performance was predicted. Hydrodynamic coefficients in the mathematical model were obtained by rudder open water, horizontal planar motion mechanism tests of the same model ship. In particular, in static drift and pure yaw tests which were conducted at a speed of 2 to 8 knots, the linear hydrodynamic coefficients varied with the ship speed. The effect of the ship speed on the linear coefficients was considered in the mathematical model, and manoeuvring motions, such as turning circles and zig-zags, were simulated with various approach speeds and analyzed.

Development of Wireless Measurement System for Bridge Using PDA and Fiber Optical Sensor (PDA와 광섬유 센서를 이용한 교량의 무선계측 시스템 개발)

  • Kwak, Kae-Hwan;Hwang, Hae-Sung;Jang, Hwa-Sup;Kim, Woo-Jong;Kim, Hoi-OK
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.88-96
    • /
    • 2009
  • This study proposes a wireless measurement system that is a new safety management system by using an FBG sensor and a PDA. The sensor part has many advantages of implementing a wireless measurement system, and the study emploies an FBG-LVDT sensor, FBG-STRAIN sensor, FBG-TEMP sensor, and FBG-ACC sensor, using FBG sensors. Also, the study show a configuration of a signal process system for operating a wireless transmission system of FBG sensors applied to the signal process system, and engrafted the cutting edge information technology industry in order to display from a remote distance using a PDA. In order to verify the applicability of the developed FBG sensors and wireless measurement monitoring system to the field, their accuracy, and usability, the study has conducted a static and dynamic test to a bridge in the field. The study made an assessment of service for the vibration of the bridge by applying dynamic data measured by an FBG-LVDT sensor and FBG-ACC sensor to Meister's curve and prepared methods for assessing the vibration of the bridge by proposing a standard of vibration limitation given the service of vibration of the bridge. As a follow up for this study, it would be necessary to set up an overall model for the standard of service assessment established in this study.

Acute and Chronic Toxicity of Phenol to Mysid, Archaeomysis kokuboi (곤쟁이, Archaeomysis kokuboi에 미치는 phenol의 급성 및 만성독성)

  • KIM Jeong-Seon;CHIN Pyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.1
    • /
    • pp.87-97
    • /
    • 1995
  • Acute and chronic toxicity of phenol on the mortality, long-term survival and respiration rates of the mysid, Archaeomysis kokuboi adult and juvenile were examined. This experiment was condurted by static bioassay procedure with the different salinity at $25^{\circ}C$ In lethal test, the test animals were exposed to 6 different phenol concentrations to determine $LC_{50}$ and I$LT_{50}$ (median lethal concentration and time) values. The $LC_{50}$ values with the exposure time for the mysid adult ranged from 31.31ppm to 1.49ppm phenol and for the mysid juvenile ranged from 6.90ppm to 0.26ppm in all experimental groups. Mortality was increased with the decrease of salinity, The $96hr-LC_{50}$ values at 16, 24 and $32\%o$ salinity for the mysid adult were 1.49, 2.71 and 4.53ppm phenol, white the values for the mysid juvenile were 0.26, 0.56 and 0.71ppm, respectively. The ratios of $96hr-LC_{50}$ values for the mysid adult to those for the mysid juvenile at 16, 24 and $32\%p$ salinity were 5.73, 4.84 and 6.38, respectively. The mysid juveniles were more sensitive to phenol than the mysid adults. Compared $LT_{50}$ values for the mysid adult with those for the mysid juvenile, the $LT_{50}$ values for the mysid adult ranged from 384.7 to 29.0 hours at 1.7-127ppm phenol concentrations and for the mysid juvenile ranged from 132.2 to 18.7 hours at 0.5~6.Oppm phenol concentrations. The lowest $LT_{50}$ values for the mysid adult and juvenile were showed at the combination of the highest experimental concentration of phenol and the lowest experimental salinity. The mysid juveniles showed lower $LT_{50}$ values than those of adults. The chronic effects of phenol on the mysid at the sublethal effective concentration of phenol were lower in the $32\%o$ salinitr group than 16 or $24\%o$ salinity groups. Oxygen consumption rates of the mysid adult were decreased with the increase of phenol concentration and exposure time, and decreased significantly in lower salinity at the same concentration or phenol.

  • PDF

Fracture resistance and marginal fidelity of zirconia crown according to the coping design and the cement type (코핑 디자인과 시멘트에 따른 지르코니아 도재관의 파절 저항성)

  • Sim, Hun-Bo;Kim, Yu-Jin;Kim, Min-Jeong;Shin, Mee-Ran;Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.194-201
    • /
    • 2010
  • Purpose: The purpose was to compare the marginal fidelity and the fracture resistance of the zirconia crowns according to the various coping designs with different thicknesses and cement types. Materials and methods: Zirconia copings were designed and fabricated with various thicknesses using the CAD/CAM system (Everest, KaVo Dental GmbH, Biberach., Germany). Eighty zirconia copings were divided into 4 groups (Group I: even 0.3 mm thickness, Group II: 0.3 mm thickness on the buccal surface and the buccal half of occlusal surface and the 0.6 mm thickness on the lingual surface and the lingual half of occlusal surface, Group III: even 0.6 mm thickness, Group IV: 0.6 mm thickness on the buccal surface and the buccal half of occlusal surface and the 1.0 mm thickness on the lingual surface and the lingual half of occlusal surface) of 20. By using a putty index, zirconia crowns with the same size and contour were fabricated. Each group was divided into two subgroups by type of cement: Cavitec$^{(R)}$ (Kerr Co, USA) and Panavia-$F^{(R)}$ (Kuraray Medical Inc, Japan). After the cementation of the crowns with a static load compressor, the marginal fidelity of the zirconia crowns were measured at margins on the buccal, lingual, mesial and distal surfaces, using a microscope of microhardness tester (Matsuzawa, MXT-70, Japan, ${\times}100$). The fracture resistance of each crown was measured using a universal testing machine (Z020, Zwick, Germany) at a crosshead speed of 1 mm/min. The results were analyzed statistically by the two-way ANOVA and oneway ANOVA and Duncan's multiple range test at $\alpha$=.05. Results: Group I and III showed the smallest marginal fidelity, while group II demonstrated the largest value in Cavitec$^{(R)}$ subgroup (P<.05). For fracture resistance, group III and IV were significantly higher than group I and II in Cavitec$^{(R)}$ subgroup (P<.05). The fracture resistances of Panavia-$F^{(R)}$ subgroup were not significantly different among the groups (P>.05). Panavia-$F^{(R)}$ subgroup showed significantly higher fracture resistance than Cavitec$^{(R)}$ subgroup in group I and II (P<.05). Conclusion: Within the limitation of this study, considering fracture resistance or marginal fidelity and esthetics, a functional ceramic substructure design of the coping with slim visible surface can be used for esthetic purposes, or a thick invisible surface to support the veneering ceramic can be used depending on the priority.

Usefulness of the Salivagram for the Diagnosis of Brain Lesions in Patients with Aspiration Pneumonia (뇌병변 환자에서 흡인성 폐렴 진단을 위한 Salivagram의 유용성)

  • Oh, Shin Hyun;Choi, Yung Sook;Ro, Dong Wook;Nam-Koong, Hyuk;Kim, Jae Sam;Leee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.48-52
    • /
    • 2013
  • Purpose: Bed, living a long time is required in adult patients with brain lesions such as stroke, traumatic brain injury, and Parkinson's disease, causing pneumonia and respiratory diseases may be due to aspiration of food or saliva. In patients with recurrent pneumonia or pulmonary symptoms, there is a need to determine the possibility of pulmonary aspiration due to aspiration of saliva. Materials and Methods: Saliva due to aspiration pneumonia diagnosis in patients with brain lesions request for inspection to the Department of Nuclear Medicine, 10 patients (male 6, female 4) were included in this study. Patients were fasted before the test, $^{99m}Tc_{O4}$ 185 MBq (5 mCi) of less than 1 mL of solution was administered in the oral cavity. Administration and 20 minutes of dynamic imaging acquisition, and immediately after that the static images were acquired. Delayed scan after 2-4 hours if necessary. Results: Positivity rate of all 10 patients was 60%. In 4 patients showed positive reactions after the administration of oral cavity in a 20-minute dynamic imaging were able to confirm whether the aspiration. In the remaining 2 patients, four hours of additional delay tests were able to confirm whether the aspiration. Conclusion: Does not require changes in patient posture compared to the other checks that can be diagnosed with aspiration pneumonia. A simple test and takes less time. Therefore be useful in providing information for the diagnosis and treatment modality.

  • PDF

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel. undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesio-distally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference on fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even of that portion consists of mainly enamel and a little dentin structure.

  • PDF

FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN (복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구)

  • Choi, Hoon-Soo;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.177-183
    • /
    • 2008
  • It was reported that esthetic composite resin restoration reinforces the strength of remaining tooth structure with preserving the natural tooth structure. However, it is unknown how much the strength would be recovered. The purpose of this study was to compare the fracture resistance of three types of undermined cavity filled with composite resin with that of non-cavitated natural tooth. Forty sound upper molars were allocated randomly into four groups of 10 teeth. After flattening occlusal enamel, undermined cavities were prepared in thirty teeth to make three types of specimens with various thickness of occlusal structure (Group $1{\sim}3$). All the cavity have the 5 mm width mesiodistally and 7 mm depth bucco-lingually. Another natural 10 teeth (Group 4) were used as a control group. Teeth in group 1 have remaining occlusal structure about 1 mm thickness, which was composed of mainly enamel and small amount of dentin. In Group 2, remained thickness was about 1.5 mm, including 0.5 mm thickness dentin. In Group 3, thickness was about 2.0 mm, including 1 mm thickness dentin. Every effort was made to keep the remaining dentin thickness about 0.5 mm from the pulp space in cavitated groups. All the thickness was evaluated with radiographic Length Analyzer program. After acid etching with 37% phosphoric acid, one-bottle adhesive (Single $Bond^{TM}$, 3M/ESPE, USA) was applied following the manufacturer's recommendation and cavities were incrementally filled with hybrid composite resin (Filtek $Z-250^{TM}$, 3M/ESPE, USA). Teeth were stored in distilled water for one day at room temperature, after then, they were finished and polished with Sof-Lex system. All specimens were embedded in acrylic resin and static load was applied to the specimens with a 3 mm diameter stainless steel rod in an Universal testing machine and cross-head speed was 1 mm/min. Maximum load in case of fracture was recorded for each specimen. The data were statistically analyzed using one-way analysis of variance (ANOVA) and a Tukey test at the 95% confidence level. The results were as follows: 1. Fracture resistance of the undermined cavity filled with composite resin was about 75% of the natural tooth. 2. No significant difference in fracture loads of composite resin restoration was found among the three types of cavitated groups. Within the limits of this study, it can be concluded the fracture resistance of the undermined cavity filled with composite resin was lower than that of natural teeth, however remaining tooth structure may be supported and saved by the reinforcement with adhesive restoration, even if that portion consists of mainly enamel and a little dentin structure.

The Effect of Exercise Program for Prevention of Falling on Physical Fitness, Posture and Fall Prevention Self-Efficacy for Elderly Women (넘어짐 예방 운동이 여성노인의 체력, 자세, 낙상효능감에 미치는 영향)

  • Son, Nam Jeong;Yi, Kyung Ock;An, Ju Yeun
    • 한국노년학
    • /
    • v.37 no.1
    • /
    • pp.237-250
    • /
    • 2017
  • The purpose of this study is to analyze the effects of exercise program for prevention of falling on physical fitness, posture and fall prevention self-efficacy for elderly women. 30 females above the age of 65 were subjects for this study. Over an twelve week period, 14women in the experimental group performed exercise 2 times a week for 60 minutes per session. 16women in the control group didn't participate in the exercise program. The independent variable was a exercise program for prevention of falling. Dependent variables were physical fitness, posture and fall prevention self-efficacy. Prevention of falling exercise program is consisted of an elastic band using exercise and Korean dance movement exercise. Physical fitness consisted of grip strength, upper and lower body endurance, cardiovascular endurance, flexibility, balance, coordination. The posture was measured the static posture when standing, using a high-resolution camera, body style to automatically measure the distance and angle(M-zen, Korea). Posture was measured in both the coronal and sagittal plane via reference board. Fall prevention self-efficacy was measured via questionnaire using the Korea Falls Self-Efficacy Scale (FES-K). The physical fitness, posture and fall prevention self-efficacy were measured twice with pre and post exercise, and the difference between groups with Wilcox signed rank test, and the group-specific post verification was carried out with U-validated methods (Mann Whitney U test). Statistical significance level was verified by setting the p<.05. Lower body endurance, cardiovascular endurance, flexibility, balance and coordination significantly increased in the experimental group. The control group was no significant increase in physical fitness variables. shoulder slope angle, pelvic slope angle(coronal/sagittal), leg length difference, scapular inferior angle and left/right calcaneus angle significantly decreased in the experimental group. Both the experimental group and control group were no significant increase in fall prevention self efficacy. The prevention of falling exercise program for elderly women indicated the positive changes in physical fitness(except grip strength) and posture(except upper body slope). However, there are no significant differences of falling prevention self-efficacy between the both group. Thus, the prevention of falling exercise program for the elderly has been proved that it is highly efficient on improving physical fitness and posture proofreading. However, we still need to consider supplement exercise for grip strength and upper body slope.