• 제목/요약/키워드: Static Switch

검색결과 73건 처리시간 0.028초

Al-3%Ti 박막의 피로성질에 대한 시편 크기 영향 (Specimen Size Effect on Fatigue Properties of Surface-Micromachined Al-3%Ti Thin Films)

  • 박준협;명만식;김윤재
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1708-1711
    • /
    • 2007
  • This paper presents high cycle fatigue properties of an Al-3%Ti thin film, used in a RF (radio-frequency) MEMS switch for a mobile phone and also describes new test method for obtaining static and dynamic characteristics of thin film and reliability evaluation method on MEMS device with thin film developed by authors. Durability should be ensured for such devices under cycling load. Therefore, with the proposed specimen and test procedure, tensile and fatigue tests were performed to obtain mechanical and fatigue properties. The specimen was made with dimensions of $1000{\mu}m$ long, $1.0{\mu}m$ thickness, and 3 kinds of width, 50, 100 and $150{\mu}m$. High cycle fatigue tests for each width were also performed, from which the fatigue strength coefficient and the fatigue strength exponent were found to be 193MPa and .0.02319 for $50{\mu}m$, 181MPa and -0.02001 for $100{\mu}m$, and 164MPa and -0.01322 for $150{\mu}m$, respectively. We found that the narrower specimen is, the longer fatigue life of Al-3%Ti is and the wider specimen is, the more susceptible to stress level fatigue life of Al-3%Ti was.

  • PDF

싸이리스타 소자의 직렬연결형 고전압 스위치스택 개발 (Development of High Voltage Switch Stack with Thyristors Stacked in Series)

  • 손윤규;오종석;장성덕;조무현;노성채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2597-2600
    • /
    • 1999
  • Semiconductor devices can be series stacked for the application of high voltage switching. It can provide high reliability and long lifetime by the safe design with a reasonable margin. The equal voltage distribution at solid-state switches in series should be guaranteed. Static and dynamic voltage division, over current protection must be considered carefully in the design stage. A fast switching thyristor is a good candidate for the high power pulse applications. A high voltage switching module is designed and tested. Its specifications are working voltage of 70 kV, switching pulse width of 120${\mu}s$, peak switching current of 220A, maximum repetition rate of 200pps. The module can be series connected to get higher working voltage. This paper presents the design details and the test results are compared with expected circuit simulations.

  • PDF

SI-Thyristor의 내부 임피던스 계산을 통한 최적 스위칭 제어 (Optimal switching method of SI-Thyristor using internal impedance evaluation)

  • 주흥진;김봉석;황휘동;박정호;고광철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.122-122
    • /
    • 2010
  • A Static Induction Thyristor (SI-Thyristor) has a great potential as power semiconductor switch for pulsed power or high voltage applications with fast turn-on switching time and high switching stress endurance (di/dt, dV/dt). However, due to direct commutation between gate driver and SI-Thyristor, it is difficult to design optimal gate driver at the aspect of impedance matching for fast gate current driving into internal SI-Thyristor. Thus, to penetrate fast positive gate current into steady off state of the SI-Thyristor, it is proposed and proceeded the internal impedance calculation of the SI-Thyristor at steady off state with the gate driver while switching conditions that are indicated applied gate voltage, $V_{GK}$ and applied high voltage across anode and cathode, $V_{AK}$.

  • PDF

무정전 전원장치 효율 향상에 대한 연구 (Efficiency Improvement of Uninterruptible Power Supply Systems)

  • 오홍일;권종원;박용만;오드게럴;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.288-290
    • /
    • 2006
  • An efficiency improving method for Uninterruptible Power Supply System(UPS) was developed by using OP-AMP based application circuits such as voltage detection device, current detection device and static switch control device. The efficiency improving algorithm was made by mixing the operating concepts of On-Line type UPS with the operating concepts of Off-Line type UPS. The UPS' inverter does not work if the UPS' output load current is not higher than the low load operating current which is about 0-30(%) of the UPS' output load capacity. The low load operating current is adjustable within the half of the UPS' output load capacity. If the UPS' output load current is rising over than the low load operating current, the UPS' inverter starts working and the inverter output power feeds to the loads of UPS. If UPS' input power breaks out while UPS' inverter does not operate because the load current is low, the inverter starts working within 4(ms) with excessive output voltage which is ${\pm}$8(%) of normal UPS' output voltage. Like these. UPS can continuously feeds power to it's load device and reduce power consumptions.

  • PDF

온라인 선로상정사고 분산처리를 위한 SIMD 구조의 PC 클러스터링 (The PC Clustering of the SIMD Structure for a Distributed Process of On-line Contingency)

  • 장세환;김진호;박준호
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1150-1156
    • /
    • 2008
  • This paper introduces the PC clustering of the SIMD structure for a distributed processing of on-line contingency to assess a static security of a power system. To execute on-line contingency analysis of a large-scale power system, we need to use high-speed execution device. Therefore, we constructed PC-cluster system using PC clustering method of the SIMD structure and applied to a power system, which relatively shows high quality on the high-speed execution and has a low price. SIMD(single instruction stream, multiple data stream) is a structure that processes are controlled by one signal. The PC cluster system is consisting of 8 PCs. Each PC employs the 2 GHz Pentium 4 CPU and is connected with the others through ethernet switch based fast ethernet. Also, we consider N-1 line contingency that have high potentiality of occurrence realistically. We propose the distributed process algorithm of the SIMD structure for reducing too much execution time on the on-line N-1 line contingency analysis in the large-scale power system. And we have verified a usefulness of the proposed algorithm and the constructed PC cluster system through IEEE 39 and 118 bus system.

연속전류모드에서 기생손실들을 고려한 고정주파수 LCL형 컨버터 해석 (Analysis of the Fixed Frequency LCL-type Converter at Continuous Current Mode Including Parasitic Losses)

  • 박상은;차한주
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.785-793
    • /
    • 2016
  • This paper analyzes an LCL-type isolated dc-dc converter operating for constant output voltage in the continuous conduction mode(CCM) with resistances of parasitic losses-static drain-source on resistance of power switch, ESR of resonant network(L-C-L)-using a high loaded quality factor Q assumptions and fourier series techniques. Simple analytical expressions for performance characteristics are derived under steady-state conditions for designing and understanding the behavior of the proposed converter. The voltage-driven rectifier is analyzed, taking into account the diode threshold voltage and the diode forward resistance. Experimental results measured for a proposed converter at low input voltage and various load resistances show agreement to the theoretical performance predicted by the analysis within maximum 4% error. Especially in the case of low output voltages and large loads, It is been observed that introduction of both rectifier and the parasitic components of converter had considerable effect on the performance.

저압계통 연계형 마이크로그리드의 보호감시 시스템 (Supervisory Protection System of Microgird Interconnected to Low Voltage Grids)

  • 정태영;백영식
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.36-42
    • /
    • 2011
  • This paper mainly proposes the protective coordination scheme of the microgrid system. The microgrid protection is identical to the conventional protection system separating the normal part and contingency part to reduce damage when the contingency occur at power cables, facilities. But they are different in the protection type. The conventional protection system only considers unidirectional current. However the microgrid protection should be considered not only unidirectional current but also backfeed current because various microsources and loads are installed in the microgrid system. In case the contingency occurs in microsource, when microgrid is interconnected to grid, the protection system should be configured to not separate microgrid from grid before the microsource is isolated to microgrid. And in case of fault occur in power system, the microsources should not isolated to microgrid before the static switch at PCC is tripped to separate from power system. Considering these characteristic of microgird, this paper proposes the protective coordination scheme of microgrid and implemented the on-line real time monitoring system. Especially in case the microgrid is connected to low voltage distribution system with 220/380V voltage level, the proposed protection method with power IT technology can solve the problems when the existing protective devices only applied to the microgrid system.

다이나믹 UPS 시스템의 전력품질 외란발생을 위한 전압 Sag-Swell 발생기 (Voltage Sag-Swell Generator for Power Quality Disturbance of Dynamic UPS System)

  • 변우열;김중원;이기수;노의철;김인동;전태원;김흥근
    • 전력전자학회논문지
    • /
    • 제10권1호
    • /
    • pp.102-107
    • /
    • 2005
  • 본 논문에서는 새로운 방식의 전압 sag-swell 발생기를 제안하여 UPS(Uninterruptible Power Supply), DVR(Dynamic Voltage Restorer), DSTATCOM(Distribution Static Compensator), SSTS(Solid State Transfer Switch)등의 전력품질 개선장치들의 성능시험을 하는데 용이하도록 하였다. 제안한 방식에 대하여 단상과 3상의 경우 전압 sag, swell, outage, unbalance 발생원리 및 동작원리를 설명하였으며 시뮬레이션과 실험을 통하여 효용성을 입증하였다. 제안한 방식은 간단한 구조, 높은 신뢰도, 넓은 전압변동발생 범위, 간단한 제어 등의 장점 뿐 아니라 저렴한 비용으로 시스템을 구현할 수 있는 특징이 있으므로, 특히 실험실 레벨에서 효과적으로 경제적인 시스템을 구현하고자 하는 경우에 크게 기여할 것으로 기대한다.

동적 물성치를 고려한 진공 인터럽터 충격특성의 영향인자 분석 (Parameter Study of Impact Characteristics for a Vacuum Interrupter Considering Dynamic Material Properties)

  • 임지호;송정한;허훈;박우진;오일성;안길영;최종웅
    • 대한기계학회논문집A
    • /
    • 제26권5호
    • /
    • pp.924-931
    • /
    • 2002
  • Vacuum interrupters in order to be used in various switch-gear components such as circuit breakers, distribution switches, contactors, etc. spread the arc uniformly over the surface of the contacts. The electrodes of vacuum interrupters are made of sinter-forged Cu-Cr materials for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.

Reconfigurable Flight Control Design for the Complex Damaged Blended Wing Body Aircraft

  • Ahn, Jongmin;Kim, Kijoon;Kim, Seungkeun;Suk, Jinyoung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권2호
    • /
    • pp.290-299
    • /
    • 2017
  • Reconfigurable flight control using various kinds of adaptive control methods has been studied since the 1970s to enhance the survivability of aircraft in case of severe in-flight failure. Early studies were mainly focused on the failure of actuators. Recently, studies of reconfigurable flight controls that can accommodate complex damage (partial wing and tail loss) in conventional aircraft were reported. However, the partial wing loss effects on the aerodynamics of conventional type aircraft are quite different to those of BWB(blended wing body) aircraft. In this paper, a reconfigurable flight control algorithm was designed using a direct model reference adaptive method to overcome the instability caused by a complex damage of a BWB aircraft. A model reference adaptive control was incorporated into the inner loop rate control system enhancing the performance of the baseline control to cope with abrupt loss of stability. Gains of the model reference adaptive control were polled out using the Liapunov's stability theorem. Outer loop attitude autopilot was designed to manage roll and pitch of the BWB UAV as well. A 6-DOF dynamic model was built-up, where the normal flight can be made to switch to the damaged state abruptly reflecting the possible real flight situation. 22% of right wing loss as well as 25% loss for both vertical tail and rudder control surface were considered in this study. Static aerodynamic coefficients were obtained via wind tunnel test. Numerical simulations were conducted to demonstrate the performance of the reconfigurable flight control system.