• 제목/요약/키워드: Static Recovery

검색결과 140건 처리시간 0.033초

초임계이산화탄소에 의한 어류조직 중 유기염소계 농약의 추출수율 (Extraction Efficiencies of Organochlorine Pesticides Spiked in Fish Tissues by Supercritical Carbon Dioxide)

  • 임상빈;좌미경;강순배
    • 한국식품과학회지
    • /
    • 제28권3호
    • /
    • pp.475-481
    • /
    • 1996
  • 초임계유체를 이용하여 간단하고, 신속하고, 저렴하게 식품 중의 잔류농약을 추출, 정제하는 방법을 개발하기 위하여 10종의 유기염소계 농약에 대하여 ppm수준의 농도에서 초임계 이산화탄소를 이용하여 추출 온도 및 압력 등 추출조건을 달리하여 추출수율을 측정하였다. 초임계 이산화탄소 추출에 의한 유기염소계 잔류농약 표준용액의 회수율은 103bar에서 추출온도가 증가할수록 증가하였다. 유기염소계 잔류농약 표준용액의 최대 평균 회수율은 $40^{\circ}C/172\;bar.$에서 98.3%였다. 대구, 넙치, 오징어에 첨가한 유기염소계 농약의 평균 첨가회수율은 $40^{\circ}C/172\;bar.$에서 각각 85.6, 74.6, 83.0%였다.

  • PDF

Design Study on a Variable Intake and a Variable Nozzle for Hypersonic Engines

  • Taguchi, Hideyuki;Futamura, Hisao;Shimodaira, Kazuo;Morimoto, Tetsuya;Kojima, Takayuki;Okai, Keiichi
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.713-721
    • /
    • 2004
  • Variable air intake and variable exhaust nozzle of hypersonic engines are designed and tested in this study. Dimensions for variable geometry air intake, ram combustor and variable geometry exhaust nozzle are defined based on the requirements of a pre-cooled turbojet engine. Hypersonic Ramjet Engine is designed as a scaled test bed for each component. Actuation forces of moving parts for variable intake and variable nozzle are reduced by balancing the other force in the opposite direction. A demonstrator engine which includes variable intake and variable nozzle is designed and the components are fabricated. Composite material with silicone carbide is applied for high temperature parts under oxidation environment such as leading edge of the variable intake and combustor liner. Internal cooling structure is adopted for both moving and static parts of the variable nozzle. Pressure recovery and mass capture ratio of the variable intake at Mach 5 is obtained by a hypersonic wind tunnel test. Flow characteristics of the variable nozzle are obtained by a low temperature flow test. Wall temperature and heat flux of the nozzle at Mach 3 is obtained by a firing test. As results, the intake and the nozzle are proved to be used at designed pressure and temperature environment.

  • PDF

Analytical Method for Dioxin and Organo-Chlorinated Compounds: (Ⅱ) Comparison and Extraction Methods of Dioxins from XAD-2 Adsorbent

  • 양정수;이성광;박영훈;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권6호
    • /
    • pp.689-695
    • /
    • 1999
  • Supercritical fluid extraction (SFE), ultrasonic extraction (USE), and accelerated solvent extraction (ASE) were compared with the well known Soxhlet extraction for the extraction of polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins(PCDDs) from the XAD-2 resin which was used to adsorb PCDDs in the atmosphere. XAD-2 resin spiked with five PCDDs was chosen as a sample. The optimum conditions for the extraction of PCDDs by SFE were turned out to be the use of CO2 modified with 10% toluene at 100 ℃ and 350 atm, with 5 min static extraction followed by 20 min dynamic extraction. SFE gave a good extraction rate with good reproducibility for PCDDs ranging from 68 to 98%. The ultrasonic extraction of PCDDs from XAD-2 was investigated and compared with other extractions. A probe type method was compared with a bath type. Two extraction solvents, toluene and acetone were compared with their mixture. The use of their mixture in probe type, with 9 minutes of extraction time, was found to be the optimum condition. The average recovery of the five PCDDs for USE was 82-93%. Accelerated solvent extraction (ASE) with a liquid solvent, a new technique for sample preparation, was performed under elevated temperatures and pressures. The effect of tem-perature on the efficiency of ASE was investigated. The extraction time for a 10 g sample was less than 15 min, when the organic solvent was n-hexaneacetone mixture (1 : 1, v/v). Using ASE, the average recoveries of five PCDDs ranged from 90 to 103%. SFE, USE, and ASE were faster and less laborious than Soxhlet extraction. The former three methods required less solvent than Soxhlet extraction. SFE required no concentration of the solvent extracts. SFE and ASE failed to perform simultaneous parallel extractions because of instrumental limitations.

Surface properties and interception behaviors of GO-TiO2 modified PVDF hollow fiber membrane

  • Li, Dongmei;Liang, Jinling;Huang, Mingzhu;Huang, Jun;Feng, Li;Li, Shaoxiu;Zhan, Yongshi
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.113-120
    • /
    • 2019
  • To investigate surface properties and interception performances of the new modified PVDF membrane coated with Graphene Oxide (GO) and nano-$TiO_2$ (for short the modified membrane) via the interface polymerization method combined with the pumping suction filtration way, filtration experiments of the modified membrane on Humic Acid (HA) were conducted. Results showed that the contact angle (characterizing the hydrophilicity) of the modified membrane decreased from $80.6{\pm}1.8^{\circ}$ to $38.6{\pm}1.2^{\circ}$. The F element of PVDF membrane surface decreased from 60.91% to 17.79% after covered with GO and $TiO_2$. O/C element mass ratio has a fivefold increase, the percentage of O element on the modified membrane surface increased from 3.83 wt% to 20.87%. The modified membrane surface was packed with hydrophilic polar groups (like -COOH, -OH, C-O, C=O, N-H) and a functional hydrophilic GO-polyamide-$TiO_2$ composite configuration. This configuration provided a rigid network structure for the firm attachment of GO and $TiO_2$ on the surface of the membrane and for a higher flux as well. The total flux attenuation rate of the modified membrane decreased to 35.6% while 51.2% for the original one. The irreversible attenuation rate has dropped 71%. The static interception amount of HA on the modified membrane was $158.6mg/m^2$, a half of that of the original one ($295.0mg/m^2$). The flux recovery rate was increased by 50%. The interception rate of the modified membrane on HA increased by 12% approximately and its filtration cycle was 2-3 times of that of the original membrane.

허리관절가동기법이 만성요통환자의 균형과 요통 기능장애 지수에 미치는 영향 (The Effect of Spine Mobilization Technique on Balance and the Low Back Pain Disability Index of Patients with Chronic Back Pain)

  • 양대중;박승규;강정일;김제호;정대근;김영일;엄요한
    • 대한통합의학회지
    • /
    • 제6권4호
    • /
    • pp.139-148
    • /
    • 2018
  • Purpose : The purpose of this study was to examine the effects of waist mobilization technique intervention for patients with chronic back pain on balance and the low back pain disability index. Methods : The subjects were 30 patients with chronic back pain. They were sampled and divided into a manual therapy group and a spinal decompression group. 15 subjects were randomly assigned to each group. Each training in this study participated for 6 weeks, 5 times a week, once a day, 15 minutes a day. Balance ability was measured with a balance analyzer, and the low back pain disability index was measured using the Oswestry Disability Index (ODI). Results : In the balance abilities, there was a significant difference in the manual therapy group compared to the spinal decompression group. In the low back pain disability index, there was a significant difference in the manual therapy group compared to the spinal decompression group. Conclusion : The analysis results of the effect of 6 weeks of waist mobilization technique intervention on the balance and low back pain disability index for patients with chronic back pain revealed that the manual therapy is more effective for static and dynamic balance ability and the low back pain disability index. In the future, we can promote independent life skills and expect a rapid recovery of patients with chronic back pain. Based on this study, further studies are needed on the effects of balance, the mechanical properties of muscle, and the low back pain disability index depending on various manual therapy techniques.

매립지 표면의 메탄 발산량 실측을 위한 플럭스 챔버의 방법론적 비교와 최적화 (Comparison and Optimization of Flux Chamber Methods of Methane Emissions from Landfill Surface Area)

  • 정진희;강수지;임종명;이진홍
    • 대한환경공학회지
    • /
    • 제38권10호
    • /
    • pp.535-542
    • /
    • 2016
  • 플럭스 챔버법은 비용효율적인 표면 발산량의 측정방법으로 다양한 연구 분야에 널리 이용되어 왔다. 플럭스 챔버법은 운용 방식에 따라 기울기 방식을 이용한 닫힌 챔버법(SFC)과 평형 농도 방식을 이용한 열린 챔버법(DFC)으로 분류할 수 있는데, SFC 방식은 장비가 간단하고 운용이 쉬운 반면, 직선성에 대한 불확실한 가정으로 인하여 플럭스 산정 값이 가변적인 단점이 있다. 한편, DFC 방식은 더 많은 특정 기기가 필요하지만, 어떤 애매모호함이 없이 일정한 값을 산정할 수 있다. 따라서 본 연구는 작고 조밀한 키트를 이용하여 DFC를 자체 제작하였다. 자체 제작한 DFC는 30분 이내에 평형상태에 도달하였고, 측정 초기의 불충분한 혼합을 제외하면 시료 균질도가 5% 미만이고, 회수율이 90% 이상으로 우수하였다. 이 개선된 DFC의 상대확장불확도는 7.37%로 평가되었는데, 이는 주로 통제되지 않은 유입가스에 기인한다. 연구 결과는 대규모 매립지에서 소형의 측정 키트를 이용한, 개선된 DFC 방식이 신뢰성이 높은 자료를 효과적으로 축적할 수 있음을 보여준다.

의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구 (THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS)

  • 장복숙;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

AIP면 유동측정 정확도 향상을 위한 가스터빈엔진 입구덕트 설계 연구 (Design Study of Engine Inlet Duct for Measurement Improvement of the Flow Properties on AIP)

  • 임주현;김성돈;김용련
    • 한국추진공학회지
    • /
    • 제21권3호
    • /
    • pp.49-55
    • /
    • 2017
  • 가스터빈엔진의 성능시험을 위한 엔진 입구덕트를 1D 기법으로 Sizing 하였으며, 압축기 입구유동측정면(AIP, Aerodynamic interface plane)에서 경계층 두께를 최소화하고, 코어부 마하수분포가 균일하도록 설계하였다. 노즈콘 형상은 Haack-series 모델을 적용하고, 덕트 안쪽과 바깥쪽 면적변화율이 동일하도록 입구덕트 채널 바깥반경($r_o$)를 결정하여 설계목적을 구현하고자 하였으며, 이러한 형상이 설계목표에 부합하는지 확인하기 위하여 CFD를 수행하였다. AIP면에서 정압력분포는 최대값과 최소값 차이가 0.16% 이었으며, 마하수분포에서 경계층은 덕트반경 길의 2% 이내로 설계목표를 만족하였다. 이때 균일유동 코어부는 채널높이의 95% 이상이었다. 또한 입구유동의 전온도를 측정하기 위한 키엘 전 온도레이크 위치는 온도 회복계수가 최대화 되도록 마하수가 0.1 이하 지역인 노즈콘 전방 100 mm 이내이어야 함을 확인하였다.

비부착 압축 프리스트레싱을 도입한 중공박스 거더의 거동 (Behavior of Hollow Box Girder Using Unbonded Compressive Pre-stressing)

  • 김성배;김장호;김태균;어철수
    • 대한토목학회논문집
    • /
    • 제30권3A호
    • /
    • pp.201-209
    • /
    • 2010
  • 일반적으로 PSC 거더 교량은 철근 콘크리트 부재와 달리 전단면을 사용하여 외부하중을 저항한다. 또한 설계와 시공의 용이성, 구조적 안전성, 경제성, 유지관리의 편리성 등의 장점 때문에 30 m 이하의 중/소 경간 교량에 많이 적용되고 있다. 그러나, 최근 전세계적으로 환경, 미관 등에 관심이 높아짐에 따라, 교량의 경간은 점점 길어지는 추세이다. 이러한 추세는 케이블 교량뿐만 아니라 PSC 교량에서도 나타난다. 본 연구는 시대적 흐름에 맞춰 PSC 거더를 50 m 이상의 장경간에 적용하기 위한 연구의 일환으로 상부에 H형 강재가 도입된 중공 박스 합성거더를 개발하였다. 개발된 거더는 타설 전 상부에 H형 강재에 미리 비부착 압축 프리스트레스를 주어 거더의 성능저하 시 프리스트레스력을 제거하여 성능을 회복시키는 방법이다. 개발된 거더는 실제 교량에 사용하기위한 필수적인 정적실험을 3점 재하로 4단계로 구분하여 수행하였다. 1차 하중은 균열발생시점까지로 하였으며, 하중 제거 후 미리 상부강재에 도입된 프리스트레스력을 제거하여 거더의 성능회복력을 확인하였다. 그 후, 거더가 파괴될 때까지 하중을 재하하였다. 실험 결과, 18.7 mm의 잔류변형이 발생하였으나, 상부 강재의 PS 제거에 의해 7.7 mm로 회복되었다. 즉, 상부 H형 강재에 도입된 비부착 압축프리스트레스의 제거에 의한 거더 하연의 추가 압축응력으로 하중 증가에 따른 잔류변형을 약 60%가량 회복시키는 성능향상을 보였다. 상부에 H형 강재를 시공함으로써 추후 보수보강을 용이하게 할 수 있고, 비용도 절감할 수 있다.

에어건과 6채널 스트리머를 이용한 고해상 천부 해저 탄성파탐사 (High-resolution shallow marine seismic survey using an air gun and 6 channel streamer)

  • 이호영;박근필;구남형;박영수;김영건;서갑석;강동효;황규덕;김종천
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2002년도 정기총회 및 제4회 특별심포지움
    • /
    • pp.24-45
    • /
    • 2002
  • 고해상 천부 해저 탄성파탐사 기술은 지난 수십년간 자원, 엔지니어링 탐사 및 지질 조사에 활용되어 왔다. 다중채널 탐사법이 지하구조를 파악하는데 매우 효과적임에도 불구하고 천부 해저탐사에는 간편성과 경제성 때문에 단일채널 아날로그 방식이 더 많이 사용되어 왔다. 본 연구에서는 경제적으로 탐사자료의 품질을 향상시키기 위하여 소형 에어건, 6채널 스트리머와 PC기반 시스템을 이용하여, 고해상 탐사자료를 디지털로 취득하고 이를 자료 처리하여 탄성파 단면도를 제작하였다 이러한 시험 자료취득은 지난 수년간 다른 목적의 연구와 병행하여 포항근해, 황해 그리고 경기만에서 수행되었다. 취득된 자료에 기본적인 자료처리가 적용되었는데 그 과정에는 이득회수, 디콘볼루션, 필터링, 동보정, 정보정, 공통 중간점 분류와 중합이 포함되었다. 자료처리된 단면도들의 예를 아날로그 기록과 비교하여 나타내었다. 자료처리 후 디지털 단면기록의 해상도는 크게 향상되었다. 취득 및 처리 결과는 소형 에어건, 6채널 스트리머와 PC기반 시스템을 이용한 고해상 천부 해저 탄성파탐사가 정밀한 지하구조 파악에 효과적임을 보여준다.

  • PDF