• 제목/요약/키워드: Static Measurement

검색결과 710건 처리시간 0.024초

Reaction Wheel Disturbance Reduction Method Using Disturbance Measurement Table

  • Cheon, Dong-Ik;Jang, Eun-Jeong;Oh, Hwa-Suk
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권4호
    • /
    • pp.311-317
    • /
    • 2011
  • Momentum changing actuators like reaction wheels and control moment gyros are generally used for spacecraft attitude control. This type of actuators produces force and torque disturbances. These disturbances must be reduced since they degrade the quality of spacecraft attitude control. Major disturbances are mainly due to static and dynamic imbalances. This paper gives attention to the reduction of the static and dynamic imbalance. Force/torque measurement system is used to measure the disturbance of the test reaction wheel. An identification method for the location and magnitude of the imbalance is suggested, and the corrections of the imbalance are performed using balancing method. Through balancing, the static and dynamic imbalance is remarkably reduced.

Optimal Measurement Placement for Static Harmonic State Estimation in the Power Systems based on Genetic Algorithm

  • Dehkordl, Behzad Mirzaeian;Fesharaki, Fariborz Haghighatdar;Kiyournarsi, Arash
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.175-184
    • /
    • 2009
  • In this paper, a method for optimal measurement placement in the problem of static harmonic state estimation in power systems is proposed. At first, for achieving to a suitable method by considering the precision factor of the estimation, a procedure based on Genetic Algorithm (GA) for optimal placement is suggested. Optimal placement by regarding the precision factor has an evident solution, and the proposed method is successful in achieving the mentioned solution. But, the previous applied method, which is called the Sequential Elimination (SE) algorithm, can not achieve to the evident solution of the mentioned problem. Finally, considering both precision and economic factors together in solving the optimal placement problem, a practical method based on GA is proposed. The simulation results are shown an improvement in the precision of the estimation by using the proposed method.

Structural system identification by measurement error-minimization observability method using multiple static loading cases

  • Lei, Jun;Lozano-Galant, Jose Antonio;Xu, Dong;Zhang, Feng-Liang;Turmo, Jose
    • Smart Structures and Systems
    • /
    • 제30권4호
    • /
    • pp.339-351
    • /
    • 2022
  • Evaluating the current condition of existing structures is of primary importance for economic and safety reasons. This can be addressed by Structural System Identification (SSI). A reliable static SSI depends on well-designed sensor configuration and loading cases, as well as efficient parameter estimation algorithms. Static SSI by the Measurement Error-Minimizing Observability Method (MEMOM) is a model-based deterministic static SSI method that could estimate structural parameters from static responses. In the current state of the art, this method is only applicable when structures are subjected to one loading case. This might lead to lack of information in some local regions of the structure (such as the null curvatures zones). To address this issue, the SSI by MEMOM using multiple loading cases is proposed in this work. Observability equations obtained from different loading cases are concatenated simultaneously and an optimization procedure is introduced to obtain the estimations by minimizing the discrepancy between the predicted response and the measured one. In addition, a Genetic-Algorithm (GA)-based Optimal Sensor Placement (OSP) method is proposed to tackle the OSP problem under multiple static loading cases for the very first time. In this approach, the Fisher Information Matrix (FIM)'s determinant is used as the metric of the goodness of sensor configurations. The numerical examples of a 3-span continuous bridge and a 13-story frame, are analyzed to validate the applicability of the extended SSI by MEMOM and the GA-based OSP method.

영상처리를 이용한 정적·동적 변위 계측과 속도·가속도 추산방식 연구 (Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration)

  • 허석;이호범;장일영
    • 한국소음진동공학회논문집
    • /
    • 제21권2호
    • /
    • pp.112-119
    • /
    • 2011
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, CCD(charge coupled device) image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration displacement, velocity and acceleration directly without any contact. The current resolution for the displacement measurement can be seen from the results.

Reliability and Validity of a Force-Sensing Resistor for the Measurement of Static Hindlimb Weight Distribution in Beagle Dogs

  • Heo, Su-Young;Jeong, Heejun;Jeong, Jaemin;Jeong, Seong Mok;Lee, HaeBeom
    • 한국임상수의학회지
    • /
    • 제35권5호
    • /
    • pp.206-210
    • /
    • 2018
  • The purpose of this study was to evaluate the reliability and validity of the Force-Sensing Resistor (FSR) for measurement of static hindlimb weight distribution in beagle dogs and to compare these results to a Digital Weighing Scale (DWS). Nine healthy beagle dogs were recruited for this study. Static weight distribution was evaluated four times at intervals of 5 days with each device and two observers to calculate the intra- and interobserver reliability. The intraclass correlation coefficient (ICC) values of the FSR for intraobserver reliability were moderate to good (0.74). The results for the DWS showed poor to moderate (0.56) ICC values for intraobserver reliability. The ICC values for interobserver reliability were 0.53 and 0.61 for FSR and DWS, respectively, indicating poor to moderate agreement. Our findings suggest that the Force-Sensing Resistor can be used to measure static weight distribution in veterinary medicine. However, caution should be taken when comparing measured values of static weight distribution obtained utilizing both the FSR and DWS due to their low positive correlation (R = 0.41, p < 0.01).

측정시스템의 정확도 평가와 공인화 절차 (Accuracy Evaluation and Accreditation Procedure of Measurement Systems)

  • 최주호;홍성수;유준
    • 한국군사과학기술학회지
    • /
    • 제2권2호
    • /
    • pp.261-270
    • /
    • 1999
  • 본 논문은 측정시스템의 정확도와 불확도 설정, 측정기법 및 측정시스템에 대한 공인화 방안을 제시하고 있다. 측정오차는 크게 정적오차 및 동적오차로 구분되는데, 측정시 항상 존재할 수 있는 정적오차를 구할 수 있는 오차방정식과, 공인화 절차를 제안하였다.

  • PDF

소자열화로 인한 Static 형 입력버퍼의 성능저하 (The Performance Degradation of Static Type Input Buffers due to Device Degradation)

  • 김한기;윤병오
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.561-564
    • /
    • 1998
  • This paper describes a performance degradation of static type input buffer due to the device degradation in menory devices using $0.8\mu\textrm{m}$ CMOS process. experimental results shows that the degradation of MOS device affects the Trip Point shift in static type input buffer. We have performed the spice simulation and calculated the Trip Point with model parameter and measurement data so that how much the Trip Point(VLT) variate.

  • PDF

선단지지된 항타개단강관말뚝의 축하중전이거동 (Axial Load Transfer Behavior for Driven Open-ended End bearing Steel Pipe Pile)

  • 임태경;정성민;정창규;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.589-596
    • /
    • 2002
  • In this study, static pile load tests with load transfer measurement were accomplished in the field. Yield pile capacity (or ultimate pile capacity) determined by load-settlement-time relationship was determined and axial load transfer behavior was analyzed. In the test for the four test piles were behaved as end bearing pile but ratios of skin friction to total pile capacity were 27%∼33%.

  • PDF

가상현실기반과 고전적 스쿼트 운동 방법에 따른 정적, 동적 균형지수 간 상관분석 (The Correlation between Static and Dynamic Balance Index according to the Virtual Reality-Based Squat and Conventional Squat Exercise)

  • 윤정규
    • 대한통합의학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Purpose : The purpose of this study was to examine the correlation between static and dynamic balance according to the virtual reality-based squat and conventional squat exercise. Methods : Twenty four participants were randomly assigned to the virtual reality-based squat (VRS) group (n=12) or conventional squat (CS) group (n=12). The static balance (C90 area, C90 angle, trace length, sway average velocity) and dynamic balance (forward, rearward, leftward, rightward) were measured using a force plate by BT4. The VRS group used the virtual reality system during 4 weeks, while the CS group underwent classical squat training. Independent t-test was used to test the homogeneity of the general characteristics of the subjects. The collected data was analyzed using the paired t-test for static and dynamic balance comparisons before and after exercise in both groups and Pearson's test for the correlation between static and dynamic balance according to the measured time. The significance level was set to 0.05. Results : There was no significant correlation between group and static and dynamic balance related variables (p>.05). There was a significant correlation between measurement time and static and dynamic balance related variables (p<.05). According to the measurement time, the static balance parameter C90 area in the VRS group after exercise was significantly decreased (p<.05). The values of forward, leftward and rightward in the VRS group were significantly increased after exercise (p<.05). Conclusion : It is suggested that 20 normal healthy adult men and women who have normal balance ability can improve their ability to control their posture by improving the balance ability when applying virtual reality-based squat exercise.

하지정렬의 임상적 측정방법에 대한 분석 (Analysis of Clinical Measurement Methods of Lower Extremity Alignment)

  • 공희경;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제16권2호
    • /
    • pp.17-21
    • /
    • 2004
  • We need to study about lower extremity alignment because the structure dictates the function of lower extremity. Through lower extremity alignment assessment in static posture, we recognize abnormal structural conditions which could affect dynamic motion such as gait. To evaluate of lower extremity alignment provide so many useful information, but method of measurement is so limited. Therefore, this review will assist understanding for measurement of lower extremity alignment in static posture. From now on study about the objective measurement method must be achieved much more in physical therapy.

  • PDF