• 제목/요약/키워드: Static Efficiency

검색결과 731건 처리시간 0.023초

공기주입 이중피복 플라스틱온실의 공기주입장치 설계를 위한 기초실험 (Fundamental Experiments for Design of Air Inflating Apparatus of Air-Inflated Double-Layer Plastic Greenhouse)

  • 이현우;남효석;심상연;남상운;김영식
    • 한국농공학회논문집
    • /
    • 제51권5호
    • /
    • pp.19-24
    • /
    • 2009
  • This study was conducted to provide fundamental data for design of air inflating apparatus of air-inflated double-layer plastic greenhouse. The variation of static pressure in air tube for different fans and filters, filtering performance for various kinds of filters and destruction phase of experimental greenhouse collapsed by excessive static pressure in air space were analyzed. The general type of forward centrifugal fan was recommended for inflating air space in air-inflated double-layer plastic greenhouse. The experimental greenhouse was collapsed down by excessive static pressure just like fallen by heavy snow load acting on it. The static pressure in air tube without filter decreased linearly as the number of outlet openings increased. But the pressure in air tube with filter declined quadratically, the decremental ratio diminished by the increase of outlet openings. The higher filtering efficiency and the greater decrements of static pressure in air tube, the larger capacity fan was required for maintaining proper static pressure in air space. Because the porosities of filter were blocked by dust as time goes by, the static pressure in air tube with filter decreased. The higher filtering efficiency, the less decremental ratio of static pressure in air tube as time passes by. Considering the filtering efficiency, decrement of static pressure and thickness of filter, the 5mm thickness filter of 75% efficiency was recommended for air inflating filter of air-inflated double-layer plastic greenhouse.

스태틱 믹서 개발 및 응용 (Development and Application of Static Mixer)

  • 양희천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.506-513
    • /
    • 2007
  • One of the most widely used static mixers is Sulzer type mixer. However the structure of the element is so complicated that the mixing efficiency is better than others, whereas the pressure drop is larger than the others. Therefore new elements are necessary to reduce the pressure drop and to minimize the decrease of the mixing efficiency compared with the Sulzer ones. The objectives of this study are to develop new static mixer and to perform the experimental investigation in order to evaluate the performance of the new one, and to investigate the applicability of the one in an inline coagulant mixing system for water treatment, The pressure drops of the new static mixer elements were about 4-12% lower than that of the Sulzer SMX one, and the mixing efficiency of the Sulzer SMX one was about 2-5% higher than that of the new ones. The inline coagulant mixing system with a new static mixer element performed significantly better than the traditional mechanical mixing system for turbidity removal.

마이크로 믹서의 형상 최적화 (Shape Optimization of a Micro-Static Mixer)

  • 한석영;김성훈
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.166-171
    • /
    • 2004
  • In this study, shape optimization of micro-static mixer with a cantilever beam was accomplished for mixing the mixing efficiency by using successive response surface approximations. Variables were chosen as the length of cantilever beam and the angle between horizontal and the cantilever beam. Sequential approximate optimization method was used to deal with both highly nonlinear and non-smooth characteristics of flow field in a micro-static mixer. Shape optimization problem of a micro-static mixer can be divided into a series of simple subproblems. Approximation to solve the subproblems was performed by response surface approximation, which does not require the sensitivity analysis. To verify the reliability of approximated objective function and the accuracy of it, ANOVA analysis and variables selection method were implemented, respectively. It was verified that successive response surface approximation worked very well and the mixing efficiency was improved very much comparing with the initial shape of a micro-static mixer.

  • PDF

Market Efficiency Analysis between Facility-Based and Service-Based Competition

  • Seo, Il-Won;Lee, Duk-Hee;Kim, Byung-Woon
    • ETRI Journal
    • /
    • 제30권4호
    • /
    • pp.587-596
    • /
    • 2008
  • Facility-based competition (FBC) in the telecommunications market is considered to have lower static efficiency in the short term and higher dynamic efficiency in the long term. Under service-based competition (SBC), the entrant can reduce its setup costs by leasing network facilities from the incumbent, which makes the entrant viable, pushes the market price down and promotes static efficiency. This paper attempts to measure static efficiency by comparing the profits of the incumbent and entrant in terms of consumer surplus and social welfare under each competition type by extending the Stackelberg model. The results, assuming a linear demand function and variation in regulatory level, show that FBC results in higher social welfare than SBC on the whole. However, SBC accompanied by strong regulation is also shown to have the potential to be superior over FBC. It is also revealed that FBC exhibits a higher producer surplus (particularly, the incumbent's producer surplus) and is, therefore, more desirable in terms of dynamic efficiency. When the entrant's cost is high in FBC, social welfare is shown to be lowered, implying that cost competitiveness is a necessary condition for social welfare.

  • PDF

2-모드 기계유압식 무단변속기의 성능 및 전달효율해석 (Performance and Transmission Efficiency Analysis of 2-Mode Hydro Mechanical Transmission)

  • 정규홍;김형의;김종기
    • 한국자동차공학회논문집
    • /
    • 제13권1호
    • /
    • pp.90-98
    • /
    • 2005
  • HMT is a type of continuously variable transmission which has split power flow path characteristics with gear train and hydro static unit. The benefit of improved fuel economy and high power capacity enables it to be a promising application fur large vehicles. This paper presents the analysis results including velocity, static torque, transmission efficiency and dynamic model of the HMT that is developed for city buses. The speeds or gear shafts, the static clutch torque and split power ratio for each mode are detailed here. From the analysis of HMT transmission efficiency considering the power loss in meshed gear and hydraulic unit, we can conclude that minimization of hydraulic power is necessary for improved fuel economy design. Also, the dynamic simulation result for mode shift characteristics shows that little shift shock is observed because of the synchronized rotation speed in clutch.

공공의료기관의 품질향상을 위한 정태적.동태적 분석 (Improve the Quality of Public Medical Centers for the Static, Dynamic Efficiency Analysis)

  • 문재영;김용태
    • 품질경영학회지
    • /
    • 제38권3호
    • /
    • pp.393-407
    • /
    • 2010
  • The purpose of this study is to analysis relative efficiency and efficiency in process of time. Thus we use panel data of 34 local public medical centers between 2003 and 2005 to use DEA and Malmquist analysis. The result of our this study is as flow; first, The results of static efficiency of 34 local public medical centers show 10 CCR model and 23 BCC model which is difference of efficiency by economic of scale. Second, a cause of increased efficiency is not only change of technology but also change of efficiency to management system index show between 2003 and 2005 by Malmquist analysis and contracting-out is higher than direct management between 2004 and 2005. That means efficiency of local public medical centers is their own effort and innovation not government subsidies.

벨마우스 깊이가 다른 소형축류홴의 공력특성에 대한 실험적 연구 (Experimental Study on the Aerodynamic Performance Characteristics of a Small-Size Axial Fan with the Different Depths of Bellmouth)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.73-78
    • /
    • 2013
  • A Small-size axial fan(SSAF) has widely been utilized to circulate a cooling air in a refrigerator, etc. Generally, the aerodynamic performance of SSAF is strongly dependent upon the depth between SSAF and bellmouth, and it includes axial, partially stalled, mostly stalled and radial flow regions according to the flow coefficient. In this study, four kinds of bellmouth depths were considered to analyze the aerodynamic performance of SSAF. As a bellmouth depth increases, a maximum flowrate decreases, but a maximum static pressure increases. Also, stall region includes an inflection point in all aerodynamic performance curves. Finally, a static pressure efficiency shows the maximum value of 37%.

Harmonic Axisymmetric Thick Shell Element for Static and Vibration Analyses

  • Kim, Jin-Gon
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1747-1754
    • /
    • 2004
  • In this study, a new harmonic axisymmetric thick shell element for static and dynamic analyses is proposed. The newly proposed element considering shear strain is based on a modified Hellinger-Reissner variational principle, and introduces additional nodeless degrees for displacement field interpolation in order to enhance numerical performance. The stress parameters selected via the field-consistency concept. are very important in formulating a trouble-free hybrid-mixed elements. For computational efficiency, the stress parameters are eliminated by the stationary condition and then the nodeless degrees are condensed out by the dynamic reduction. Several numerical examples confirm that the present element shows improved efficiency and yields very accurate results for static and vibration analyses.

Optimization of Blade Profile of a Plenum Fan

  • Wu, Lin;Dou, Hua-Shu;Wei, Yikun;Chen, Yongning;Cao, Wenbin;Ying, Cunlie
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.95-106
    • /
    • 2016
  • A method of optimization design for the blade profile of a centrifugal impeller by controlling velocity distribution is presented, and a plenum fan is successfully designed. This method is based on the inner flow calculation inside the centrifugal impeller, and is related to the distribution of relative velocity. The results show that after optimization, the boundary layer separation on the suction surface has been inhibited and the stability of plenum fan is improved. The flow at the impeller outlet is also studied, and the jet-wake pattern at the impeller outlet is improved obviously by optimization. The calculation result shows that the static pressure and static pressure efficiency can be increased by 15.4% and 21.4% respectively.

순차적 반응표면법을 이용한 마이크로 정적 믹서의 최적설계 (Parameter Optimization of a Micro-Static Mixer Using Successive Response Surface Method)

  • 한석영;맹주성;김성훈
    • 대한기계학회논문집A
    • /
    • 제28권9호
    • /
    • pp.1314-1319
    • /
    • 2004
  • In this study, parameter optimization of micro-static mixer with a cantilever beam was accomplished for maximizing the mixing efficiency by using successive response surface approximations. Variables were chosen as the length of cantilever beam and the angle between horizontal and the cantilever beam. Sequential approximate optimization method was used to deal with both highly nonlinear and non-smooth characteristics of flow field in a micro-static mixer. Shape optimization problem of a micro-static mixer can be divided into a series of simple subproblems. Approximation to solve the subproblems was performed by response surface approximation, which does not require the sensitivity analysis. To verify the reliability of approximated objective function and the accuracy of it, ANOVA analysis and variables selection method were implemented, respectively. It was verified that successive response surface approximation worked very well and the mixing efficiency was improved very much comparing with the initial shape of a micro-static mixer.