DOI QR코드

DOI QR Code

Development and Application of Static Mixer

스태틱 믹서 개발 및 응용

  • 양희천 (전남대학교 기계.자동차공학부)
  • Published : 2007.07.31

Abstract

One of the most widely used static mixers is Sulzer type mixer. However the structure of the element is so complicated that the mixing efficiency is better than others, whereas the pressure drop is larger than the others. Therefore new elements are necessary to reduce the pressure drop and to minimize the decrease of the mixing efficiency compared with the Sulzer ones. The objectives of this study are to develop new static mixer and to perform the experimental investigation in order to evaluate the performance of the new one, and to investigate the applicability of the one in an inline coagulant mixing system for water treatment, The pressure drops of the new static mixer elements were about 4-12% lower than that of the Sulzer SMX one, and the mixing efficiency of the Sulzer SMX one was about 2-5% higher than that of the new ones. The inline coagulant mixing system with a new static mixer element performed significantly better than the traditional mechanical mixing system for turbidity removal.

Keywords

References

  1. J. Sir and Z. Lecjaks, 'Pressure Drop and Homogenization Efficiency of a Motionless Mixer,' Chem. Eng. Commun., Vol. 16, pp. 325-334, 1982 https://doi.org/10.1080/00986448208911104
  2. S. S. Jones, 'Static Mixers for Water Treatment-A Computational Fluid Dynamics Model,' Ph. D Thesis, Georgia Institute of Technology, 1999
  3. S. Kawamura, Integrated Design of Water Treatment Facilities, Wiley, New York, 1991
  4. R. J. Latimer and A. Amirtharajah, 'Pilot Scale Comparison of Static Mixers and Backmixing Reactors for Water Treatment,' Proc. of 1998 Annual Conference, American Water Works Association, pp. 705-740, 1998
  5. J. C. Burke, 'Effectiveness of Static Mixers for Enhanced Coagulation,' Ph. D Thesis, Georgia Institute of Technology, Atlant, 1996
  6. H. C. Yang and S. K. Park, 'Pressure Drop in Motionless Mixers,' KSME Int. J., Vol. 18, No. 3, pp. 526-532, 2004
  7. H. C. Yang, S. K. Park and S. W. Oh, 'Mixing Characteristics of Static Mixers,' Proc. of the KSME 2003 Spring Annual Meeting, pp. 1955-1960, 2003
  8. H. C. Yang, S. K. Park, Y. S. Eom and B. Y. Ra, 'A Study of Flow and Mixing in a Static Mixer,' Proc. of the KSME 2001 Fall Annual Meeting B, pp. 557-562, 2001
  9. OPTIMAS User Guide, Media Cybernetics, 1999
  10. D. M. Hobbs, 'Characterization of a Kenics Static Mixer Under Larminar Flow Condition,' Ph. D Thesis, The State University of Newjersy, 1997
  11. A. Cybulski and K. Werner, 'Static Mixers Criteria for Applications and Selection,',Int. Chem. Eng., Vol. 26, pp. 171-180, 1986
  12. D. Rauline, P. A. Tanguy, J. L. Belyec and J. Bousquet, 'Numerical Investigation of the Performance of Several Static Mixers,',The Canadian J. of Chem. Eng., Vol. 76, pp. 527-535, 1998 https://doi.org/10.1002/cjce.5450760325

Cited by

  1. Performance characteristics of inline mixing and coagulation system vol.38, pp.3, 2014, https://doi.org/10.5916/jkosme.2014.38.3.269
  2. SMX형 정적 믹서의 압력손실 특성 vol.32, pp.6, 2007, https://doi.org/10.3795/ksme-b.2008.32.6.479