• 제목/요약/키워드: Static Analyzer

검색결과 78건 처리시간 0.025초

하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION)

  • 조혜원;김난영;김유리
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

Photoemission Electron Micro-spectroscopic Study of the Conductive Layer of a CVD Diamond (001)$2{\times}1$ Surface

  • Kono, S.;Saitou, T.;Kawata, H.;Goto, T.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.7-8
    • /
    • 2010
  • The surface conductive layer (SCL) of chemical vapor deposition (CVD) diamonds has attracting much interest. However, neither photoemission electron microscopic (PEEM) nor micro-spectroscopic (PEEMS) information is available so far. Since SCL retains in an ultra-high vacuum (UHV) condition, PEEM or PEEMS study will give an insight of SCL, which is the subject of the present study. The sample was made on a Ib-type HTHP diamond (001) substrate by non-doping CVD growthin a DC-plasma deposition chamber. The SCL properties of the sample in air were; a few tens K/Sq. in sheet resistance, ${\sim}180\;cm^2/vs$ in Hall mobility, ${\sim}2{\times}10^{12}/cm^2$ in carrier concentration. The root-square-mean surface roughness (Rq) of the sample was ~0.2nm as checked by AFM. A $2{\times}1$ LEED pattern and a sheet resistance of several hundreds K/Sq. in UHV were checked in a UHV chamber with an in-situ resist-meter [1]. The sample was then installed in a commercial PEEM/S apparatus (Omicron FOCUS IS-PEEM) which was composed of electro-static-lens optics together with an electron energy-analyzer. The presence of SCL was regularly monitored by measuring resistance between two electrodes (colloidal graphite) pasted on the two ends of sample surface. Figure 1 shows two PEEM images of a same area of the sample; a) is excited with a Hg-lamp and b) with a Xe-lamp. The maximum photon energy of the Hg-lamp is ~4.9 eV which is smaller that the band gap energy ($E_G=5.5\;eV$) of diamond and the maximum photon energy of the Xe-lamp is ~6.2 eV which is larger than $E_G$. The image that appear with the Hg-lamp can be due to photo-excitation to unoccupied states of the hydrogen-terminated negative electron affinity (NEA) diamond surface [2]. Secondary electron energy distribution of the white background of Figs.1a) and b) indeed shows that the whole surface is NEA except a large black dot on the upper center. However, Figs.1a) and 1b) show several features that are qualitatively different from each other. Some of the differences are the followings: the two main dark lines A and B in Fig.1b) are not at all obvious and the white lines B and C in Fig.1b) appear to be dark lines in Fig.1a). A PEEMS analysis of secondary electron energy distribution showed that all of the features A-D have negative electron affinity with marginal differences among them. These differences can be attributed to differences in the details of energy band bending underneath the surface present in SCL [3].

  • PDF

낙동강 삼각주에 항타된 PHC말뚝의 지지력을 위한 재하시험과 지지력 공식의 비교연구 (Comparative Study between Design Methods and Pile Load Tests for Bearing Capacity of Driven PHC Piles in the Nakdong River Delta)

  • ;정성교;김성렬;정진교
    • 한국지반공학회논문집
    • /
    • 제23권3호
    • /
    • pp.61-75
    • /
    • 2007
  • 우리나라에서는 암반 및 자갈층과 같은 단단한 층 내에 깊은 기초를 매입하는 것이 일반적이다. 그러나 Chaophraya(Bangkok)와 Mississippi강 삼각주에서 실시되고 있는 것과 같이, 대심도 낙동강 삼각주 퇴적토에서도 말뚝의 지지층으로써 중간 깊이에 위치하는 모래 및 모래질 자갈층을 고려할 필요가 있다. 이 연구는 이 지역에서 PHC 말뚝을 요구하는 깊이까지 항타할 때, 말뚝의 지지력을 위한 적절한 평가법을 찾고자 하였다. 지반조사는 두 현장의 5개소에서 실시되었다. 말뚝의 지지력은 지반조사 결과를 이용하고 CPT에 근거한 평가법과 여러 다른 해석법을 적용하여 계산되었으며, 상호 비교가 이루어 졌다. 항타된 5개의 말뚝에 대해 매입된 전 깊이에 걸쳐 잘 알려진 PDA시험이 체계적으로 수행되었다. 여러 평가법에 의하여 계산된 지지력은 PDA 및 정재하 시험결과와 함께 비교되었다. 그 결과, 주면마찰력은 set-up 효과에 따라 지배적으로 영향을 받으며, 장시간 경과 후에는 $\beta$법에 의한 결과와 좋은 일치를 보였다. 선단 지지력은 과소평가되는 PDA시험 보다는 정재하시험결과에 근거하여 적절한 평가법을 선정하였다. 최종적으로, CPT결과를 이용하여 이 지역에 적합한 지지력의 평가법을 도출하였다.

Effect of crude fibre additives ARBOCEL and VITACEL on the physicochemical properties of granulated feed mixtures for broiler chickens

  • Jakub Urban;Monika Michalczuk;Martyna Batorska;Agata Marzec;Adriana Jaroszek;Damian Bien
    • Animal Bioscience
    • /
    • 제37권2호
    • /
    • pp.274-283
    • /
    • 2024
  • Objective: The aim of the study was to evaluate the physicochemical properties (nutrient composition, pH, water content and activity, sorption properties) and mechanical properties (compression force and energy) of granulated feed mixtures with various inclusion levels of crude fibre concentrates ARBOCEL and VITACEL for broiler chickens, i.e. +0.0% (control group - group C), +0.3%, +0.8%, +1.0%, +1.2%. Methods: The feed mixtures were analyzed for their physicochemical properties (nutrient composition by near-infrared spectroscopy, pH with the use a CP-401 pH meter with an IJ-44C glass electrode, water content was determined with the drying method and activity was determined with the Aqua Lab Series 3, sorption properties was determined with the static method) and mechanical properties (compression force and energy with the use TA-HD plus texture analyzer). The Guggenheim-Anderson-de Boer (GAB) model applied in the study correctly described the sorption properties of the analyzed feed mixtures in terms of water activity. Results: The fibre concentrate type affected the specific surface area of the adsorbent and equilibrium water content in the GAB monolayer (p≤0.05) (significantly statistical). The type and dose of the fibre concentrate influenced the dimensionless C and k parameters of the GAB model related to the properties of the monolayer and multilayers, respectively (p≤0.05). They also affected the pH value of the analyzed feed mixtures (p≤0.05). In addition, crude fibre type influenced water activity (p≤0.05) as well as compression energy (J) and compression force (N) (p≤0.001) (highly significantly statistical) of the feed mixtures. Conclusion: The physicochemical analyses of feed mixtures with various inclusion levels (0.3%, 0.8%, 1.0%, 1.2%) of crude fiber concentrates ARBOCEL or VITACEL demonstrated that both crude fiber types may be used in the feed industry as a feedstuff material to produce starter type mixtures for broiler chickens.

감시림프절 검사 시 입자크기에 따른 대체 방사성의약품의 유용성평가 (Evaluation on the Usefulness of Alternative Radiopharmaceutical by Particle size in Sentinel Lymphoscintigraphy)

  • 조광모;정영환;최도철;신주철
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.36-41
    • /
    • 2016
  • 1. 목적 현재 감시림프절 검사에는 $^{99m}Tc-Phytate$만 사용한다. 만약 일시적으로 공급이 중단된다면 대체 가능한 방사성의약품이 없는 실정이다. 본 연구에서는 감시림프절 검사의 성공요소 중 방사성의약품의 입자 크기에 중점을 두어 핵의학 검사에 사용되는 방사성의약품들의 입자크기를 측정해보고 감시림프절 검사 시 $^{99m}Tc-Phytate$를 대체할 수 있는 방사성의약품을 찾아보고자 하였다. 2. 방법 Zetasizer Nano ZS90 (Malvern, UK)를 통하여 체내검사에 이용되는 Phytate, MAG3, DPD, DMSA, MAA, DTPA, HDP의 입자크기를 분석하였다. 동물실험은 9주령의 백서 6마리를 사용하여 각각 3마리씩 $^{99m}Tc-Phytate$를 사용한 대조군과 감시림프절 검사 시 유용하다고 알려진 입자크기를 갖는 $^{99m}Tc-MAG3$, $^{99m}Tc-DPD$$^{99m}Tc-DMSA$를 사용한 실험군을 설정 하였다. 백서의 발등에 11.1 MBq ($300{\mu}Ci$)을 인슐린 주사기를 이용하여 피하주사 하고, 동적영상과 정적지연영상을 획득한 후 육안으로 서혜부 림프절을 관찰하였다. 3. 결과 나노입자 분석기를 통하여 측정한 입자크기는 각각 Phytate 105~255 nm ($81.9{\pm}23%$), MAG3 91~255 nm ($98.7{\pm}17%$), DPD 105~342 nm ($77.3{\pm}11%$), DMSA 164~342 nm ($99.2{\pm}35%$), MAA 1281~2305 nm($90.6{\pm}82%$), DTPA 342~1106 nm ($79.4{\pm}28%$), HDP 295~955 nm ($94{\pm}33%$)로 나타났다. $^{99m}Tc-Phytate$를 사용한 대조군은 모든 실험에서 서혜부 림프절을 육안으로 확인 할 수 있었다. $^{99m}Tc-Phytate$와 가장 유사한 크기의 $^{99m}Tc-MAG3$는 서혜부 림프절에 저류하지 않고 빠르게 통과하였고, $^{99m}Tc-DPD$$^{99m}Tc-DMSA$를 이용한 실험에서는 서혜부 림프절에 대조군과 비슷하게 저류되어 림프절 관찰이 용이하였다. 결론: 본 실험을 통해서 핵의학 체내검사에 사용되는 방사성의약품들의 입자크기 분포를 확인하였다. $^{99m}Tc-MAG3$$^{99m}Tc-Phytate$와 가장 유사한 입자크기를 가지고 있으나 동물실험에서는 서혜부 림프절이 관찰되지 않고 빠르게 신장을 통해 배출되었다. 반면에 $^{99m}Tc-DPD$$^{99m}Tc-DMSA$의 경우 유사시 대체 방사성의 약품으로 사용 될 수 있을 것으로 생각된다.

  • PDF

타이밍 구동 FPGA 분석적 배치 (Timing Driven Analytic Placement for FPGAs)

  • 김교선
    • 전자공학회논문지
    • /
    • 제54권7호
    • /
    • pp.21-28
    • /
    • 2017
  • FPGA 배치 툴 연구는 학계에서도 단순한 가상 아키텍처 모델 가정에서 벗어나 상용 툴처럼 캐리체인이나 광폭함수 멀티플렉서, 메모리/승산기 블록 등의 성능 및 밀도를 향상시키는 소자들을 포함하는 현실적인 모델을 적용하기 시작하였다. 이 때 발생하는 실제적 이슈들을 다룬 사전 패킹, 다층 밀도 분석 등의 기법이 초기 분석적 배치 (Analytic Placement)에 적용되어 밀도를 분산시키면서 배선 길이를 효과적으로 최소화한 연구가 앞서 발표된 바 있다. 더 나아가 궁극적으로는 타이밍을 최적화해야하기 때문에 많은 연구에서는 타이밍 제약 조건을 만족시키기 위한 기법들이 제시되고 있다. 그러나 초기 배치 후 진행되는 배치 적법화 및 배치 개선에서 주로 적용될 뿐 분석적 배치에서 이러한 타이밍 기법을 적용한 사례는 거의 없다. 본 논문에서는 사전 패킹 및 다층 밀도 분석 등의 기법이 구현된 기존 분석적 배치에 타이밍 제약 조건 위반을 검출하고 이를 최소화하는 기법을 결합하는 방안을 소개한다. 먼저 정적 타이밍 검증기를 집적하여 배선 길이가 최소화된 기존 배치 결과의 타이밍을 검사해 보았으며 위반을 감소시키기 위해 신호 도착 시간 (Arrival Time)을 최소화하는 함수를 분석적 배치의 목적 함수에 추가하였다. 이 때 각 클록마다 주기가 다를 수 있기 때문에 각 클록별로 함수를 따로 계산해 합산하는 방안이 제안되었다. 또한, 위반이 없는 클록 도메인의 신호 경로들도 불필요하게 단축될 수 있기 때문에 음수 슬랙 (Negative Slack)을 계산하여 이를 최소화하는 함수를 추가로 제안하여 비교하였다. 영역 분할 기법 (Partitioning)을 기반으로 배선 길이를 최소화하는 기존 배치 적법화를 그대로 사용한 후 타이밍 검증을 통해 초기 분석적 배치 단계에서 타이밍 개선 효과를 분석하였다. 배치 적법화 시 추가적인 타이밍 최적화 기법이 사용되지 않았기 때문에 타이밍 개선이 있다면 이것은 전적으로 분석적 배치의 목적 함수개선에 의한 효과이다. 12개 실용예제에 대해 실험한 결과, 목적 함수에 도착 시간 함수가 적용되었을 때 그렇지 않았을 때보다 최악 음수 슬랙 (Worst Negative Slack)이 평균 약 15% 정도 감소되었으며 음수 슬랙 함수가 적용되었을 때 이보다 약 6%정도 추가로 더 감소됨을 확인하였다.

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존치질의 두께 (법랑질 /법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교 평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, $1{\sim}3$군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $Z-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.

  • PDF

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존 치질의 두께 (법랑질 / 법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, 1$\sim$3군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $SZ-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.