• Title/Summary/Keyword: Static

Search Result 13,522, Processing Time 0.042 seconds

Comparison of static MRI and pseudo-dynamic MRI in tempromandibular joint disorder patients (측두하악관절장애 환자에서의 static MRI와 pseudo-dynamic MRI의 비교연구)

  • Lee, Jin-Ho;Yun, Kyoung-In;Park, In-Woo;Choi, Hang-Moon;Park, Moon-Soo
    • Imaging Science in Dentistry
    • /
    • v.36 no.4
    • /
    • pp.199-206
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate comparison of static MRI and pseudo-dynamic (cine) MRI in temporomandibular joint (TMJ) disorder patients. Materials and Methods: In this investigation, 33 patients with TMJ disorders were examined using both conventional static MRI and pseudo-dynamic MRI. Multiple spoiled gradient recalled acquisition in the steady state (SPGR) images were obtained when mouth opened and closed. Proton density weighted images were obtained at the closed and open mouth position in static MRI. Two oral and maxillofacial radiologists evaluated location of the articular disk, movement of condyle and bony change respectively and the posterior boundary of articular disk was obtained. Results: No statistically significant difference was found in the observation of articular disk position, mandibular condylar movement and posterior boundary of articular disk using static MRI and pseudo-dynamic MRI (P<0.05). Statistically significant difference was noted in bony changes of condyle using static MRI and pseudo-dynamic MRI (P<0.05). Conclusion: This study showed that pseudo-dynamic MRI didn't make a difference in diagnosing internal derangement of TMJ in comparison with static MRI. But it was considered as an additional method to be supplemented in observing bony change.

  • PDF

Comparison of Effects for Application of Proprioceptive Neuromuscular Facilitation Technique and Static Stretching on the Calf Muscle (비복근의 고유수용성 신경근육 촉진법과 정적 신장에 대한 효과 비교)

  • Kim, Won-Ho;Park, Yong-Tack;Hwang, Sung-Yon;Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.2 no.2
    • /
    • pp.56-65
    • /
    • 1995
  • The purpose of this study was to compare the effects of one proprioceptive neuromuscular facilitation technique and static stretching on calf muscle tightness. The subjects consist of 9 hemiplegics, and 9 quadriplegics. The eighteen subjects were randomly divided into 3 groups: prorioceptive neuromuscular facilitation(6 persons), static stretching(6 persons) and control(6 persons). Contract relax antagonist contract and static stretching techniques were applied continuously for twenty minutes each. Of the many proprioceptive neuromuscular facilitation techniques, only the contract relax antagonist contract technique was applied. The static stretching technique was applied with the subject placed in standing on a seventy degree inclined tilt table for twenty minutes. A wedge was placed under the feet to obtain maximum dorsiflexion. Wedge thickness varied with each subject. Results revealed: (1) a significant difference between the experimental and the control groups(p<0.05). (2) a significant difference between contract relax antagonist contract and static stretching groups(p<0.05). (3) At day five, the final increments were: contract relax antagonist contract $11.9{\pm}1.90^{\circ}$, static stretching $7.7{\pm}2.3^{\circ}$(mean${\pm}$standard deviation).

  • PDF

The Effects of High-heeled Shoes on Static Balance and EMG Activity of Lower Extremity Muscles for Young Women (젊은 여성에서 높은 굽 신발의 착용기간에 따른 정적균형과 다리 근활성도 분석)

  • Lee, Myoung-Hee;Chang, Jong-Sung;Lee, Sang-Yeol;Ju, Joung-Youl;Bae, Sung-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.4 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • Purpose : The purpose of this study is to determine the effects of high heeled shoes on the static balance and EMG activity of lower extremity muscles. Methods Twenty subjects were composed of control group(wearing low-heeled shoes) and experimental group(wearing high-heeled shoes). Two groups participated in bearfoot standing and measured static balance and EMG activity of lower extremity muscles. Balance Performance Monitor(BPM) was used to measure the static balance and FlexComp $Infiniti^{TM}$ was used to measure the EMG activity of lower extremity muscles. Results In static balance, sway area and path of experimental group was significantly larger than control group(p<0.05). And sway velocity of experimental group was significantly faster than control group(p<0.05). They means static balance of experimental group was significantly lower than control group(p<0.05). In EMG activity, L5 paraspinalis and biceps femoris of experimental group was significantly more increased than that of control group(p<0.05). Conclusion : The long-time experience in wearing high heeled shoes may have caused change in static balance and EMG activity of lower extremity muscles.

  • PDF

Development of Functional Pulp Tray for Prevention of Static Electricity (정전기 방지를 위한 기능성 펄프 트레이 개발)

  • Lee, Ji-Young;Kim, Chul-Hwan;Nam, Hye-Gyeong;Park, Hyeong-Hun;Kwon, Sol;Lee, Young-Min
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.5
    • /
    • pp.52-60
    • /
    • 2015
  • Static electricity is an imbalance of electric charges within or on the surface of a material. All packed items that are particularly sensitive to static discharge must be protected by antistatic treatment. Otherwise, static electricity generated by an electrical insulator may cause serious damages to some sensitive electronics. In order to remove or prevent a buildup of static electricity, packed items must be treated with the application of an antistatic agent, which helps any excess charge to be evenly distributed. Functional pulp tray used for packing of electronic goods was developed with application of an antistatic agent. As the concentration of the antistatic agent increased, charging voltage and surface resistance of molded pulps decreased. The increase of humidity in surrounding atmosphere around molded pulps led to the decrease of accumulation of static charges. In conclusion, the surface treatment of the antistatic agent not only reduced or eliminated buildup of static electricity in the surface, but also prevented generation of tiny dirts from molded tray.

An Investigation of Dynamic Characteristics of Structures Subjected to Dynamic Load from the Viewpoint of Design (동하중을 받는 구조물의 동적특성에 관한 설계 관점에서의 고찰)

  • Lee Hyun-Ah;Kim Yong-Il;Kang Byung-Soo;Kim Joo-Sung;Park Gyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.10 s.253
    • /
    • pp.1194-1201
    • /
    • 2006
  • All the loads in the real world are dynamic loads and structural optimization under dynamic loads is very difficult. Thus the dynamic loads are often transformed to static loads by dynamic factors, which are believed equivalent to the dynamic loads. However, due to the difference of load characteristics, there can be considerable differences between the results from static and dynamic analyses. When the natural frequency of a structure is high, the dynamic analysis result is similar to that of static analysis due to the small inertia effect on the behavior of the structure. However, if the natural frequency of the structure is low, the inertia effect should not be ignored. Then, the behavior of the dynamic system is different from that of the static system. The difference of the two cases can be explained from the relationship between the homogeneous and the particular solutions of the differential equation that governs the behavior of the structure. Through various examples, the difference between the dynamic analysis and the static analysis are shown. Also dynamic response optimization results are compared with the results with static loads transformed from dynamic loads by dynamic factors, which show the necessity of the design considering dynamic loads.

Quenching of Ofloxacin and Flumequine Fluorescence by Divalent Transition Metal Cations

  • Park, Hyoung-Ryun;Oh, Chu-Ha;Lee, Hyeong-Chul;Choi, Jae-Gyu;Jung, Beung-In;Bark, Ki-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.12
    • /
    • pp.2002-2010
    • /
    • 2006
  • This study examined the quenching of ofloxacin (OFL) and flumequine (FLU) fluorescence by $Cuj^{2+}$, $Ni^{2+}$, $Co^{2+}$ and $Mn^{2+}$ in an aqueous solution. The change in the fluorescence intensity and lifetime was measured at various temperatures as a function of the quencher concentration. According to the Stern-Volmer plots, the fluorescence emission was quenched by both collisions (dynamic quenching) and complex formation (static quenching) with the same quencher but the effect of static quenching was larger than that of dynamic quenching. Large static and dynamic quenching constants for both OFL and FLU support significant ion-dipole and orbital-orbital interactions between fluorophore and quencher. For both molecules, the static and dynamic quenching constants by $Cu^{2+}$ were the largest among all the metal quenchers examined in this study. In addition, both the static and dynamic quenching mechanisms by $Cu^{2+}$ were somewhat different from the quenching caused by other metals. Between $Ni^{2+}$ and FLU, a different form of chemical interaction was observed compared with the interaction by other metals. The change in the absorption spectra as a result of the addition of a quencher provided information on static quenching. With all these metals, the static quenching constant of FLU was larger than those of OFL. The fluorescence of OFL was quite insensitive to both the dynamic and static quenching compared with FLU. This property of OFL can be explained by the twisted intramolecular charge transfer in the excited state.

A Packet Distribution Routing for Balancing Energy-Consumption in MANET (MANET의 에너지 분산 소모를 위한 패킷 분산 라우팅)

  • Jin, Dong-Xue;Choi, Yong-Jun;Park, Hee-Joo;Kim, Chong-Gun
    • The KIPS Transactions:PartC
    • /
    • v.15C no.2
    • /
    • pp.79-86
    • /
    • 2008
  • MANET(Mobile Ad hoc Network) is a collection of two or more nodes equipped with wireless communications and constrained by the factor of energy limitation. The running out of energy on some nodes may bring down the performance of network seriously. For solving the problems above, this paper uses completely separated Node-Disjoint multipaths from a source to a destination as many as possible. And, based on average, minimum or variance of energy values on the each multipath, the packets are distributed on paths. Generally, collecting methods for energy information can be classified into two main categories, Static and Dynamic. As the different energy values collected, the packet distribution methods are classified into six criteria, Static-Average, Static-Minimum, Static-Variance, Dynamic-Average, Dynamic-Minimum and Dynamic-Variance respectively. The performance of the packet distribution methods and that of AODV are compared by NS2 simulation.

Reliability Verification of Numerical Prediction Method on Pile Behaviour Characteristics using Field Static Loading Test (현장정재하시험을 이용한 말뚝 거동특성 수치해석 예측기법의 신뢰성 검증)

  • Nam, Hosung;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.9
    • /
    • pp.11-18
    • /
    • 2017
  • Numerical analysis method for prediction of pile behaviour characteristics has widely been used in detail design process before construction because field static loading test requires high cost. However, the reliability verification of numerical analysis of result is not permitted compare with field test. In this study, to verify the numerical analysis results, pile behaviour prediction was compared with field static loading test results. For exact analysis of interaction between pile and ground, soil investigation and in-situ test such as boring, SPT and bore-hole shear test were performed before pile static loading test. During the static loading test, pile behaviour characteristics were analyzed under every loading condition. After static pile loading test, numerical analysis was carried out under same condition with static pile loading test. In the numerical analysis, to apply same loading condition with each loading condition in the field test and to compare with between the results of numerical analysis, the field test results for reliability were verified with the results of numerical analysis.

The Effect of Therapeutic Ultrasound and Static Stretching of the Hamstring Muscle on Flexibility and Static Balance Ability (초음파 치료와 정적 스트레칭이 뒤넙다리근의 유연성과 정적균형에 미치는 영향)

  • Cho, Seung-bong;Park, Mi-young;Won, Ji-sun;Kim, Ye-lin;Hong, Joon-taek;Kim, Seong-ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.26 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • Background: The purpose of present study was to examine the effect of ultrasound therapy and static stretching on hamstring length and balance. Design: Randomized Controlled Trial. Methods: A total of 30 adults in S college, Seongnam city, Gyeonggi-do, between the ages of 20-30 were randomly assigned to two groups. Group 1 (n=15) had ultrasound therapy, called US group. Group 2 (n=15) had static stretching, called SS group. Measurements were taken prior to starting the program and after completing the experiment using Finger to floor test and Active knee extension test to get the results of hamstring flexibility and the ability of static balance. Paired t-test was used to compare each group pre-test values to post-test values and to compare US post-test values to SS post-test values on PASW 18.0. Results: 1) Both hamstring SS group and US group had significant increase (p<.05) in Finger to floor test and Active knee extension test. 2) Dominant leg standing had significant change (p<.05) only in US group. 3) There was no significant difference between US group and SS group. Conclusion: Results showed that US group and SS group had an effect on changes in hamstring length (p<.05). However, they did not show a significant increase in static balance. Further effective studies on hamstring SS group and US group were needed based on this examination.

Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site (산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현)

  • Jang, Mun-Seok;Lee, Eung-Hyuk
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.