• Title/Summary/Keyword: State of Emergency

Search Result 464, Processing Time 0.025 seconds

A Study on the Transient State Characteristics of TFR-8 Cable caused by Over Current (과전류에 의한 TFR-8 케이블의 과도상태 특성에 관한 연구)

  • Kim, Byeong-Jo;Kim, Jae-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.57-63
    • /
    • 2015
  • The incidence of fires caused by electrical factors has increased with the growth in domestic electrical consumption. According to the national fire data system of national emergency management agency, electrical fires accounted for 20% of all domestic fires in the last 10 years. Electrical fires are mainly caused by short circuit, leakage current, defect in an electrical equipment, over load, utility fault, etc. The fault current can be several times larger than the nominal current, thereby exceeding the rated current of cable. Consequently, the cable conductor, typically copper wire, heats up to a temperature that ignites surrounding combustibles. This paper describes the transient characteristics of the 0.6/1kV, TFR-8 cable have been investigated, and analyzed under the over current conditions for reduce the risk of electrical fire by experimental and FEM analysis. The experimental and FEM(Finite Element Method) analysis results of temperature and resistance variation according to the over current in copper wires were analyzed. The experimental results coincide well with the FEM analysis.

Rapid Visual Deterioration Caused by Posterior Fossa Arachnoid Cyst

  • Shin, Chang Jin;Rho, Myeongho;Won, Yu Sam;Kim, Si On
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.3
    • /
    • pp.314-318
    • /
    • 2016
  • Posterior fossa is a site next to the middle fossa where arachnoid cyst frequently occurs. Generally, most arachnoid cysts are asymptomatic and are found incidentally in most cases. Although arachnoid cysts are benign and asymptomatic lesions, patients with posterior fossa arachnoid cysts often complain of headaches, gait disturbance, and ataxia due to the local mass effects on the cerebellum. We observed a patient with a posterior fossa arachnoid cyst who had visual symptoms and a headache, but did not have gait disturbance and ataxia. We recommended an emergency operation for decompression, but the patient refused for personal reasons. After 7 days, the patient revisited our hospital in a state of near-blindness. We suspected that the arachnoid cyst induced the hydrocephalus and thereby the enlarged third ventricle directly compressed optic nerves. Compressed optic nerves were rapidly aggravated during the critical seven days; consequently, the patient's vision was damaged despite the operation. Considering the results of our case, it is important to keep in mind that the aggravation of symptoms cannot be predicted; therefore, symptomatic arachnoid cysts should be treated without undue delay.

Development of Gas Detector Location Index Technique to Prevent Explosion Accidents of Offshore Plant (해양플랜트 폭발사고 방지를 위한 가스감지기 위치 선정 방법 연구)

  • Sohn, Jung Min;Paik, Jeom Kee;Kim, Sang Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • Release of hazardous and flammable gas is a significant contributor to risk. The ignition of flammable gas clouds can lead to explosion accidents in the offshore installations. A gas detector, which is one of active protect systems, brings the module into a safe state through emergency shut down processes and reduces the damage by eliminating the dangerous releases. It is critical to understand the gas release, the wind field, and the complex geometry of installations to determine gas detector placement. In this paper, the Gas detector Location Index (GLI) which is a novel index for optimal detector location determination to efficiently prevent explosion accident using probabilistic approach.

Managing the Vulnerability of Megacities in North America and Europe to Seismic Hazards

  • Waugh, William L.
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.20-30
    • /
    • 2001
  • The science and technology of seismic hazard mitigation are increasingly being shared among scientists and policy makers around the world. Administrative expertise is also being shared. While there is still tremendous unevenness in technical and administrative capacities and resources, a global community of emergency managers is developing and there is a globalization of expertise. Hazards are better understood, tools for risk assessment are improving, techniques for hazard mitigation are being perfected, and communities and states are implementing more comprehensive disaster preparedness, response, and recovery programs. Priorities are also emerging and hazard mitigation has emerged as the priority of choice in North America and Europe. An increasingly important component of hazard mitigation is resilience, in terms of increased capacities for disaster mitigation and recovery at the community and even individual levels. Each year, more is known about the locations and natures of seismic hazards, although there are still unknown and poorly understood fault lines and limited understanding of related disasters such as tsunamis and landslides. More is known about the impact of earthquakes on the built environment, although nature still provides surprises to confound man's best extorts to reduce risk. More is known about human nature and how people respond to uncertain risk and when confronted by certain catastrophe. However, despite the increased understanding of seismic phenomena and how to protect people and property, there is much that needs to be done to reduce the risk, particularly in major metropolitan areas.

  • PDF

A Case of Acute Respiratory Failure After Trichloroethylene Inhalation (트리클로로에틸렌 흡입으로 인한 호흡부전 1례)

  • Park, Jae-Seok;Jeon, Young-Woo;Kim, Young-Il;Gil, Hyo-Wook;Yang, Jong-Oh;Lee, Eun-Young;Hong, Sae-Yong
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.1
    • /
    • pp.30-33
    • /
    • 2011
  • Trichloroethylene (TCE, $C_2HCl_3$), which was introduced as a gas for general anesthesia and analgesia in early 1900's has been widely used in industry as an organic solvent. Occupational exposure to TCE is an important medical problem. Manifestations of acute exposure to TCE include mucocutaneous irritation, hepatotoxicity, cognitive impairment, sleep, headache, respiratory insufficiency and death. We report a 38-year-old man who was admitted to a department of emergency medicine after occupational inhalation exposure to TCE. He rapidly developed semicoma and respiratory depression. After mechanical ventilation, hypercapnea and hypoxemia disappeared and his mental state again became alert. Careful evaluation and proper respiratory support are important for respiratory failure after occupational TCE inhalation.

  • PDF

Crisis Management System in Hospitals (병원의 위기관리 시스템)

  • Kim, Hyeongjin
    • Korea Journal of Hospital Management
    • /
    • no.spc
    • /
    • pp.85-95
    • /
    • 2016
  • This study is to introduce a comprehensive framework of a crisis management system developed at a prominent hospital in South Korea. Throughout recent decades, especially in the recent years, the way in which to cope with both internal and external challenges has been one of the most critical issues. Since the incident management system in the U.S. is acknowledged as the most advanced crisis management model in the world, a portion of this study refers to the Hospital Incident Command System(HICS) provided by the California Emergency Medical Services Authority(EMSA). Nevertheless, the framework suggested in this article was designed based on a distinctive Korean hospital setting. The main contents of this study are as follows; categorization of each type of crisis, organization of a crisis management team in a non-crisis or crisis state, crisis assessment by life cycle stage, and establishment of crisis management protocol. Even though many types of crises are unspecified, those can be categorized into external crisis, medical crisis, and utility & activity failure. A crisis management organization should be operated and consisted differently- depending on a crisis or non-crisis situation. From a life-cycle perspective, the range by which the crisis should be managed extends from pre-stage to post-stage of the crisis. It is important to set proper scenarios and manuals by crisis type to develop a crisis management framework of high quality. With continuous efforts, hospitals can prepare for the uncertainty to better concentrate on core business operations.

January 24, 2020 Sivrice Earthquake and the response of the masonry Haci Yusuf Tas (New) mosque

  • Firat, Fatih K.;Ural, Ali;Kara, Mehmet E.
    • Earthquakes and Structures
    • /
    • v.22 no.4
    • /
    • pp.331-343
    • /
    • 2022
  • Masonry structures are the most common structural systems that have been used almost all over the world from the earliest ages of history to the present day. These structural systems are often unfavorably affected by natural disasters such as earthquakes. The main reason for this is that they are built without sufficient engineering knowledge. On January 24, 2020, a severe earthquake occurred near the Sivrice District of Elazığ in eastern Turkey. According to the Turkish Directorate of Disaster and Emergency Management (AFAD), the magnitude of the earthquake was 6.8 and the focal depth 8 km. This earthquake caused damage and destruction to the masonry structures used extensively in the region. The Hacı Yusuf Taş (new) mosque in the Malatya city center, located about 64 km from the epicenter of the earthquake, was among the buildings affected by the earthquake. The mosque has smooth-cut stone walls and domes made of brick units. The main dome of the structure was severely damaged during the earthquake. In this study, information about the earthquake is first provided, and the damage to the mosque is then interpreted via photographs. In addition, two separate finite element models were produced, where the current state of mosque and solution suggestions are presented, and response spectrum analyses were carried out. According to these analyses and field observations, a buttress system to the main walls of the structure should be constructed in the direction which has little lateral rigidity.

Rupture of the Trachea and the Esophagus Following Blunt Trauma: A Report of a Case (Blunt Trauma 에 의한 기관-식도 파열의 치험 1례)

  • 정윤채
    • Journal of Chest Surgery
    • /
    • v.8 no.2
    • /
    • pp.119-124
    • /
    • 1975
  • This is a case report of the rupture of the trachea and the esophagus following external blunt trauma without any associated injury. A 7 year old male patient was brought to the emergency room. Hanyang University Hospital, on 23 Jul, 1974 while he played under the pile of pingpong table A table was fall down over the patient accidentally. The patient was injured by the table and found lying in unconsciousness on the ground.There was subcutaneous emphysema on his anterior chest and neck. A contusion on the upper part of the sternum was noted. The breathing sound were diminished over the left side of the chest. Ronchi were heard over the right lung field. This patient was suffered from vomiting, dypsnea, and irritable mental state after this accident. On the chest roentgenogram in A-P view, hyperlucency at the mediastinum and parapericardiac area suggested the pneumomediastinum. On the next day, a diagnosis of the tracheal and esophageal rupture was confirmed by the esophagogram with Lipiodol swallowing. A right thoracotomy was performed and ruptured orifice of the trachea and the esophagus were closed with interrupted sutures. Postoperative course was uneventful and primary closure of the rupture of the trachea and the esophagus were succeeded.

  • PDF

Hybrid Control System for Managing Voltage and Reactive Power in the JEJU Power System

  • Seo, Sang-Soo;Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byong-Jun;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.4
    • /
    • pp.429-437
    • /
    • 2009
  • This paper proposes a hybrid voltage controller based on a hierarchical control structure for implementation in the Jeju power system. The hybrid voltage controller utilizes the coordination of various reactive power devices such as generators, switched shunt devices and LTC to regulate the pilot voltage of an area or zone. The reactive power source can be classified into two groups based on action characteristics, namely continuous and discrete. The controller, which regulates the pilot bus voltage, reflects these characteristics in the coordination of the two types of reactive power source. However, the continuous type source like generators is a more important source than the discrete type for an emergency state such as a voltage collapse, thereby requiring a more reactive power reserve of the continuous type to be utilized in the coordination in order to regulate the pilot bus voltage. Results show that the hybrid controller, when compared to conventional methods, has a considerable improvement in performance when adopted to control the pilot bus voltage of the Jeju island system.

Improvement of Transient Performance of Synchronous Generator using Feedforward Controller (피드포워드 제어기를 사용한 동기발전기의 과도특성 개선)

  • An, Young-Joo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.2
    • /
    • pp.57-62
    • /
    • 2018
  • A brush-less type synchronous generator driven by an internal-combustion engine is used for emergency electric source. These types of generators have to maintain a certain range of output voltage even under the sudden load change conditions such as full load application and removal. This paper describes a method for suppressing the output voltage of a synchronous generator that operates excessively when the load fluctuates. The method used in this paper is a feedforward control method in which the main voltage control consists of a feedback loop using a typical PID controller and the load current is detected as a disturbance element and compensated directly. A feedforward system is constructed in which the load current is regarded as disturbance, and the appropriate feedforward controller configuration and parameters are found through simulation. Finally, it can be seen through the experiment that the feedforward control is performed properly. It can be seen that the generator terminal voltage is recovered to the steady state in a short period of time as compared with the existing PID control method even when the entire load of the generator is changed.