• Title/Summary/Keyword: State Explosion

Search Result 154, Processing Time 0.035 seconds

Experimental Study on the Explosion and Fire Risks of Mobile Phone Batteries (휴대폰 배터리의 폭발 및 화재 위험성에 관한 실험적 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.111-120
    • /
    • 2016
  • This is an experimental study to analyze the explosion and fire hazards of mobile phone batteries. Using the lithium-ion batteries currently used on smart phone as the experiment samples, the experiments were conducted by overcharging, internal and external short circuit, and thermal shock with the potential of explosion and fire caused by careless use or abnormal conditions. The experiment results showed that, in the case of overcharging and external short circuit, there was no explosion and fire hazard in the normal operation of the protection circuit module (PCM), but there were big risks when the PCM faulted conditions were assumed. In the case of the experiments by internal short circuit and thermal shock, such risks varied depending on a battery charge state. In other words, it could be verified that there were low risks of explosion and fire in a full discharge state, but there were high risks in a full charge state. These experiment results suggest that to minimize the explosion and fire hazards of mobile phone batteries, an alarm device is necessary when the PCM fault occurs. In addition, a solid battery case should be made and safety equipment, such as a cooling device to avoid high temperature, is needed.

Prediction of Upper Explosion Limits (UEL) of Acids and Ketones by Using Setaflash Tester (Setaflash 장치를 이용한 산류와 케톤류의 폭발상한계 예측)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.114-119
    • /
    • 2011
  • Explosion limit and flash point are the major combustion properties used to determine the fire and explosion hazards of the flammable substances. In this study, in order to predict upper explosion limits (UEL) for acids and ketones, the upper flash point of these were measured under the VLE (vaporliquid equilibrium) state by using Setaflash closed cup tester (ASTM D3278). The UELs calculated by Antoine equation by using the experimental upper flash point are usually lower than the several reported UELs. From the given results, using the proposed experimental and predicted method, it is possible to research the upper explosion limits of the other flammable substances.

NUMERICAL ANALYSIS ON THE REACTOR CORE EXPANSION AND ENERGY BEHAVIORS DURING CDA USING UNDERWATER EXPLOSION THEORY (수중폭발 이론을 사용한 노심폭주사고 시 노심 팽창 및 에너지 거동 수치해석)

  • Kang, S.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.8-14
    • /
    • 2016
  • A numerical analysis is conducted to estimate the core expansion and the energy behaviors induced by a core disruptive accident in a sodium-cooled fast reactor. The numerical formulation based on underwater explosion theory is carried out to simulate the core explosion inside the reactor vessel. The transient pressure, temperature and expansion of the core are examined by solving the equation of state and nonlinear governing equation of momentum conservation in one-dimensional spherical coordinates. The energy balance inside the computation domain is examined during the core expansion process. Heat transfer between the core and the sodium coolant, and the bubble rise during the expansion process are briefly investigated.

Dynamic performance of girder bridges with explosion-proof and aseismic system

  • Wang, Jingyu;Yuan, Wancheng;Wu, Xun;Wei, Kai
    • Structural Engineering and Mechanics
    • /
    • v.61 no.3
    • /
    • pp.419-426
    • /
    • 2017
  • Recently, the transportation of dangerous explosive goods is increasing, which makes vehicle blasting accidents a potential threat for the safety of bridge structures. In addition, blasting accidents happen more easily when earthquake occurs. Excessive dynamic response of bridges under extreme loads may cause local member damage, serviceability issues, or even failure of the whole structure. In this paper, a new explosion-proof and aseismic system is proposed including cable support damping bearing and steel-fiber reinforced concrete based on the existing researches. Then, considering one 40m-span simply supported concrete T-bridge as the prototype, through scale model test and numerical simulation, the dynamic response of the bridge under three conditions including only earthquake, only blast load and the combination of the two extreme loads is obtained and the applicability of this explosion-proof and aseismic system is explored. Results of the study show that this explosion-proof and aseismic system has good adaptability to seism and blast load at different level. The reducing vibration isolation efficiency of cable support damping bearing is pretty high. Increasing cables does not affect the good shock-absorption performance of the original bearing. The new system is good at shock absorption and displacement limitation. It works well in reducing the vertical dynamic response of beam body, and could limit the relative displacement between main girder and capping beam in different orientation so as to solve the problem of beam falling. The study also shows that the enhancement of steel fibers in concrete could significantly improve the blast resistance of main beam. Results of this paper can be used in the process of antiknock design, and provide strong theoretical basis for comprehensive protection and support of girder bridges.

Assessment of steel components and reinforced concrete structures under steam explosion conditions

  • Kim, Seung Hyun;Chang, Yoon-Suk;Cho, Yong-Jin
    • Structural Engineering and Mechanics
    • /
    • v.60 no.2
    • /
    • pp.337-350
    • /
    • 2016
  • Even though extensive researches have been performed for steam explosion due to their complex mechanisms and inherent uncertainties, establishment of severe accident management guidelines and strategies is one of state-of-the arts in nuclear industry. The goal of this research is primarily to examine effects of vessel failure modes and locations on nuclear facilities under typical steam explosion conditions. Both discrete and integrated models were employed from the viewpoint of structural integrity assessment of steel components and evaluation of the cracking and crushing in reinforced concrete structures. Thereafter, comparison of systematic analysis results was performed; despite the vessel failure modes were dominant, resulting maximum stresses at the all steel components were sufficiently lower than the corresponding yield strengths. Two failure criteria for the reinforced concrete structures such as the limiting failure ratio of concrete and the limiting strains for rebar and liner plate were satisfied under steam explosion conditions. Moreover, stresses of steel components and reinforced concrete structures were reduced with maximum difference of 12% when the integrated model was adopted comparing to those of discrete models.

A Study on the Development of Explosion Proof ESD Detector and Intrinsic Safety Characteristics Analysis (방폭구조 ESD Detector 개발 및 본질안전 특성 분석에 관한 연구)

  • Byeon, Junghwan;Choi, Sang-won
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • Article 325 (Prevention of Fire Explosion due to Electrostatic) of the Rule for Occupational Safety and Health Standard specifies that in order to prevent the risk of disasters caused by static electricity, fire, explosion and static electricity in the production process, However, in order to do this, it is absolutely necessary to use a pre-detection technology and a detector for antistatic discharge prediction, which is a precautionary measure by static electricity in a fire / explosion hazard place, but in Korea, And there is no technical standard for the application of the technology of the explosion proof structure of the related equipment. Research methods include domestic and overseas electrostatic discharge detection technology and literature investigation of related equipment explosion proofing technology, domestic and foreign electrostatic discharge detection device production and use situation investigation, advanced foreign technology data analysis and benchmarking. In particular, we sought to verify the results of empirical experiments using electrostatic discharge detection technology through sample purchase and analysis of related major products, development of optimization technology through prototype production, evaluation, and supplementation, and expert knowledge through expert consultation. The results of this study were developed and fabricated two prototypes of electrostatic discharge detector based on the technology / standard related to electrostatic discharge detection technology in Korea and abroad through development of electrostatic discharge detection technology and development and production of detector. In addition, based on the development of electrostatic discharge detection technology, we developed an intrinsic safety explosion proof ib class explosion proof technology applicable to the process of using and handling flammable gas and flammable liquid vapor and combustible dust. In the case of the over voltage and minimum voltage are supplied to the explosion-proof structure ESD detector, check the state of the circuit and the transient and transient currents generated by the coil and capacitor elements during the input and standby of the signal pulse voltage. Explosion-proof equipment-Part 11: Intrinsically safe explosion proof structure The comparative evaluation with the reference curve in Annex A of "i" confirms that the characteristics of the intrinsically safe explosion protection structure are met.

A Hierarchical Model for Mobile Ad Hoc Network Performability Assessment

  • Zhang, Shuo;Huang, Ning;Sun, Xiaolei;Zhang, Yue
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.8
    • /
    • pp.3602-3620
    • /
    • 2016
  • Dynamic topology is one of the main influence factors on network performability. However, it was always ignored by the traditional network performability assessment methods when analyzing large-scale mobile ad hoc networks (MANETs) because of the state explosion problem. In this paper, we address this problem from the perspective of complex network. A two-layer hierarchical modeling approach is proposed for MANETs performability assessment, which can take both the dynamic topology and multi-state nodes into consideration. The lower level is described by Markov reward chains (MRC) to capture the multiple states of the nodes. The upper level is modeled as a small-world network to capture the characteristic path length based on different mobility and propagation models. The hierarchical model can promote the MRC of nodes into a state matrix of the whole network, which can avoid the state explosion in large-scale networks assessment from the perspective of complex network. Through the contrast experiments with OPNET simulation based on specific cases, the method proposed in this paper shows satisfactory performance on accuracy and efficiency.

New Modularization Method to Design Supervisory Control of Automated Laboratory Systems (자동화 시스템의 관리제어 설계를 위한 새로운 모듈화 기법)

  • Jung, Taeyoung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.38-47
    • /
    • 2014
  • This paper describes the application of discrete event systems theory to the design of an automated laboratory system. Current automated laboratory systems typically consist of several interacting processes that must be carefully sequenced to avoid any possible process conflicts. Discrete Event Systems (DES) theory and Supervisory Control Theory (SCT) can be applied together as effective methods of modeling the system dynamics and designing supervisory controllers to precisely sequence the many processes that such systems might involve. Classical approaches to supervisory controller design tend to result in complex controller structures that are difficult to implement, maintain, and upgrade. In this paper, a new approach to designing supervisory controllers for automated laboratory systems is introduced. This new approach uses a modular controller structure that is easier to implement, maintain, and upgrade, and deals with "state explosion" issues in a novel and efficient way.

Hierarchical Verification Methodology of Discrete Event Systems (이산사건 시스템의 계층적 검증방법론)

  • Song, Hae-Sang;Lee, Wan-Bok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.5
    • /
    • pp.1029-1036
    • /
    • 2007
  • State explosion is a well-known problem that impedes analysis md testing of discrete event systems, thus making the verification of large systems intrinsically difficult job. This paper suggests a hierarchical verification methodology of untimed DEVS model which can alleviate the state explosion problem. The method is a repetitive procedure of designing and verifying between the upper level and the lower level models abstracting away the unnecessary information with respect to a given verification task. A small example was employed to show our suggested method in detail.

The Influence of Pressure, Temperature, and Addition of CO2 on the Explosion Risk of Propylene used in Industrial Processes

  • Choi, Yu-Jung;Choi, Jae-Wook
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.610-617
    • /
    • 2020
  • In process installations, chemicals operate at high temperature and high pressure. Propylene is used as a basic raw material for manufacturing synthetic materials in the petrochemical industry; However, it is a flammable substance and explosive in the gaseous state. Thus, caution is needed when handling propylene. To prevent explosions, an inert gas, carbon dioxide, was used and the changes in the extent of explosion due to changes in pressure and oxygen concentration at 25 ℃, 100 ℃, and 200 ℃ were measured. At constant temperature, the increase in explosive pressure and the rates of the explosive pressure were observed to rise as the pressure was augmented. Moreover, as the oxygen concentration decreased, the maximum explosive pressure decreased. At 25 ℃ and oxygen concentration of 21%, as the pressure increased from 1.0 barg to 2.5 bar, the gas deflagration index (Kg) increased significantly from 4.71 barg·m/s to 18.83 barg·m/s.