• 제목/요약/키워드: Start-up tests

검색결과 55건 처리시간 0.024초

Run related probability function and their application to start-up demonstration tests

  • Bi, Yi-Ming;Oh, Jung-Taek;Cho, Gyo-Young
    • Journal of the Korean Data and Information Science Society
    • /
    • 제27권4호
    • /
    • pp.1067-1074
    • /
    • 2016
  • A start-up demonstration test is a mechanism that is usually used to determine the reliability of equipment, for example water pumps, car batteries and power generators. The simplest and oldest start-up demonstration tests are called CS (consecutive successes) which have been studied by Hahn and Gage (1983), Viveros and Balakrishnan (1993).At first Hahn and Gage (1983) discussed the start-up demonstration test. I was based on i.i.d (independently and identically distributed) binary outcomes with the specified number of consecutive successful start-ups. Oh (2016) studied CSNCF (consecutive successful, but not consecutive failures). In this paper, we investigated the CS and CSNCF models, also their applications to start-up demonstration tests. The numerical results showed that the expectations and variances of the total number of attempted start-ups until the acceptance of the unit are gradually increasing in all of the specified number of successes as the p (probability of a successful start-up in an single trial) decreases from 0.99 to 0.90. The difference between means of the CS mode and CSNCF model is small, but variances of the CS and CSNCF are big.

Implementation of dynamic start-up test experimental data as a main part of the nuclear code validation procedure: Developed RELAP5 model for VVER-1000

  • Navid Vahman;Reza Akbari
    • Nuclear Engineering and Technology
    • /
    • 제56권9호
    • /
    • pp.3826-3834
    • /
    • 2024
  • The main purposes of start-up tests in nuclear power plants (NPPs) are to ensure safe and reliable operation, verify system functionality, comply with regulatory requirements, optimize performance, and establish a foundation for ongoing plant operation and maintenance. However, the start-up tests of NPPs also could be used as a main part of the nuclear code validation procedure for several reasons including: realistic simulation, comprehensive evaluation, detection of code limitations, validation of safety margins and confidence in code predictions. The main purpose of the current study is to define and assess the validation procedure based on actual start-up test data. In this regard, the developed RELAP5 model has been validated against the actual data of VVER-1000 plant during a dynamic start-up test. The results of this full-scale validation show a good agreement between the developed RELAP5 model results and actual plant data. Finally, by defining a step by step validation procedure, it has been recommended to use the start-up phase test data as a more robust validation process which allow for full-scale validation of the nuclear code by comparing its predictions with actual plant measurements and also other advantages which have been demonstrated in the current study.

Influence of nuclear data library on neutronics benchmark of China experimental fast reactor start-up tests

  • Guo, Hui;Jin, Xin;Huo, Xingkai;Gu, Hanyang;Wu, Haicheng
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3888-3896
    • /
    • 2022
  • Nuclear data is the basis of reactor physics analysis. This paper aim at studying the influence of major evaluated nuclear data libraries, CENDL-3.2, ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0u, on the neutronics modelling of CEFR start-up tests. Results show these four libraries have a good performance and consistency in the modelling CEFR start-up tests. The JEFF-3.3 results exhibit only an 8 pcm keff difference with the measurement. The difference in criticality is decomposed by nuclide, which shows the large overestimation of CENDL-3.2 is mainly from the cross-section of 52Cr. Except for few cases, the calculation results are within 1σ of measurement uncertainty in control rod worth, sodium void reactivity, temperature reactivity, and subassembly swap reactivity. In the evaluation of axial and radial reaction distribution, there are about 65% of relative errors that are less than 5% and 82% of relative errors that are less than 10%.

Verification of OpenMC for fast reactor physics analysis with China experimental fast reactor start-up tests

  • Guo, Hui;Huo, Xingkai;Feng, Kuaiyuan;Gu, Hanyang
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3897-3908
    • /
    • 2022
  • High-fidelity nuclear data libraries and neutronics simulation tools are essential for the development of fast reactors. The IAEA coordinated research project on "Neutronics Benchmark of CEFR Start-Up Tests" offers valuable data for the qualification of nuclear data libraries and neutronics codes. This paper focuses on the verification and validation of the CEFR start-up modelling using OpenMC Monte-Carlo code against the experimental measurements. The OpenMC simulation results agree well with the measurements in criticality, control rod worth, sodium void reactivity, temperature reactivity, subassembly swap reactivity, and reaction distribution. In feedback coefficient evaluations, an additional state method shows high consistency with lower uncertainty. Among 122 relative errors in the benchmark of the distribution of nuclear reaction, 104 errors are less than 10% and 84 errors are less than 5%. The results demonstrate the high reliability of OpenMC for its application in fast reactor simulations. In the companion paper, the influence of cross-section libraries is investigated using neutronics modelling in this paper.

한국형발사체 연소기 연소시험설비의 구축 및 시운전 (Construction and Start-up Test of Hot-firing Test Facility for KSLV-II Combustion Chamber)

  • 이광진;이승재;서대반;황창환;우성필;임지혁;전준수;소윤석;김채형;김성혁;김승한;조남경;한영민
    • 한국추진공학회지
    • /
    • 제20권1호
    • /
    • pp.69-75
    • /
    • 2016
  • 본 논문은 한국형발사체 연소기 연소시험설비의 구축과 시운전 결과를 다루고 있다. 이 시험설비는 2012년부터 2014년까지 구축되었고, 2014년 하반기에 시운전이 수행되었다. 시운전 과정에는 산화제 수류시험, 연료 수류시험, 냉각수 수류시험 등이 수행되었고, 이후 점화시험이 이루어졌다. 점화시험 결과는 연소기의 시동시퀀스를 설정하는데 적용되며, 저압연소시험과 설계점 연소시험을 위한 기초자료로 활용되게 된다.

전기점화 기관의 시동 시 미연탄화수소의 배출 특성 연구 (A Study on Engine-Out HC Emissions during Sl Engine Starting)

  • 김성수
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.22-30
    • /
    • 2003
  • Engine-out HC emissions were investigated during cold and hot start. The tests were conducted according to engine cooling temperatures which were controlled by simulated coolant temperatures of cold and hot start, on a 1.5L, 4-cylinder, 16 valve, multipoint-port-fuel-injection gasoline engine. Real time engine-out HC emissions were measured at a exhaust port and cylinder head using Fast Response Flame Ionization Detector(FRFID). Unburned hydrocarbons emitted at the cold coolant temperature were much higher than those of the hot coolant temperatures. And the main source of the high HC emission was confirmed as misfire at cold coolant temperature. In addition, the effect of intake valve timing on engine-out HC emissions was investigated. The results obtained indicate that optimized intake phasing provides the potential for start-up engine-out HC emissions reduction.

산업별 창업 결정요인의 세 가지 가설 검증, 2008-2014년 (Three Hypothesis Tests for Determinants of Business Start-up)

  • 이창근
    • 지역연구
    • /
    • 제33권1호
    • /
    • pp.17-27
    • /
    • 2017
  • 본 연구의 목적은 창업의 이론적 배경에 근거하여 산업별 창업의 결정 요인을 분석하는 것이다. 이를 위해 경기 요인, 소득 요인, 기술 혁신 요인 외에 지역 요인에도 초점을 맞춰 지역 산업구조 특성 및 지역 노동시장 구조를 고려하였다. 분석결과 산업별 창업 결정 요인에 있어서 창업의 세 가지 이론은 대체로 부합한다고 할 수 있다. 경기쇠퇴기에 오히려 창업이 증가하였고, 지역 내 소비 뿐 아니라, 1인당 지방재정지출의 경우에도 창업에 긍정적 영향을 미쳐 창업을 통한 지역경제 성장을 위해 지방정부의 역할이 보다 중요하다고 하겠다. 창업보육센터가 제조업 부문에서 창업에 긍정적 영향을 주어 중앙 및 지방정부의 창업 지원정책의 일환인 창업보육센터 외에도 다양한 산학 주도형 창업보육시설 또한 활성화되어야 할 것이다. 또한 창업에 있어서 인구증가는 잠재적 수요 창출 측면에서 볼 때 매우 중요한 요소였으며, 지역 산업구조 특성과 지역 내 인적자본의 영향은 산업별로 다르게 나타났다. 제조업의 경우 집적효과가 동(同)산업의 창업에 긍정적으로 작용하였으며, 기타 서비스업의 경우 다른 모든 조건이 일정할 때 인적자본 변수가 창업에 가장 큰 영향을 미치는 것으로 나타났다.

Hot Leg Temperature Uncertainty due to Thermal Stratification

  • Jang, Ho-Cheol;Ju, Kyong-In;Kim, Young-Bo;Sul, Young-Sil;Cheong, Jong-Sik
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.29-35
    • /
    • 1996
  • For the Reactor Coolant System(RCS) flow rate measurement by the secondary calorimetric heat balance method, the coolant temperature of the hot leg is needed. Several Resistance Temperature Detectors(RTD) are installed in the hot leg to measure the temperature, but the average value of RTDs does not correctly represent the energy-averaged(bulk) temperature because of the thermal stratification phenomenon. Therefore some correction is introduced to predict the bulk temperature, but the correction inevitably contains uncertainty because the stratification is not defined well quantitatively yet. Therefore a large uncertainty for the correction has been used for the conservative estimation. But unrealistically large uncertainty causes degradation of the measurement method and yields difficulty to meet the acceptance criterion in start-up flow measurement test. In this paper, an analytical estimation is made on the correction and the related uncertainty using the measured hot leg velocity profile of System 80 reactor flow model test and the measured temperatures of YGN 3&4 and PVNGS 1&2 start-up tests. The results reveal that the magnitude of the correction uncertainty is much smaller than that used in the previous design. Therefore, the confidence on the flow rate measurement method can be improved and the difficulty in start-up flow measurement test can be lessened if the smaller correction uncertainty obtained through this estimation is applied.

  • PDF

함유소결베어링과 빗살무늬 유체베어링의 마찰 특성 및 레이저 스캐너 모터에서의 전기적 특성 (Oil-impregnated Sintered-metal Bearing and Herringbone-grooved Fluid Bearing for High-speed Scanner Motors)

  • 이영제;정광섭;정성훈
    • Tribology and Lubricants
    • /
    • 제15권1호
    • /
    • pp.108-115
    • /
    • 1999
  • The electrical and frictional properties of oil-impregnated sintered-metal bearing (OSB) and herringbone-grooved fluid bearing (HFB) with varying loads and speeds were measured. OSB shows very good performance up to 20,000 rpm and 0.05 N, and HFB successfully works up to 35,000 rpm and 0.05 N. From the endurance tests on start-stop and continuous operation, it was confirmed that those bearings could be mass-produced fur use on scanner motor in a laser scanner unit.

냉시동시 촉매의 예열시간 단축에 관한 연구 (A Study for Fast Light-Off of a Catalyst During Cold Start)

  • 조용석;이윤석
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1998년도 제17회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.69-77
    • /
    • 1998
  • In order to meet the stringent emission regulations, fast light-off of a catalyst is essential to reduce the HC and CO emissions during cold start. Cranking Exhaust Gas Ignition (CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds after cold start. The CEGI system cuts off the ignition signal for a few seconds during the cranking period. so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst. Results from the FTP-75 tests showed that the exhaust emissions with the CEGI reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

  • PDF