Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant (화력발전소 주배관 3차원 변위측정시스템 개발)

  • Song, G.W.;Hyun, J.S.;Ha, J.S.;Cho, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

  • PDF

Operation Characteristics of an UASB at High Organic Loading Condition for Thermal Elutriated Acids of Piggery Wastewater Treatment (가축분뇨 고온 세정산발효액 처리를 위한 고부하 조건에서의 UASB 운전특성)

  • Kwon, Koo-Ho;Jung, Yong Jun;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.781-785
    • /
    • 2012
  • This study was carried out to treat the thermal elutriated acids of piggery wastewater using UASB process. The UASB reactor was operated at an organic loading rate (OLR) of $7.4\;kgCOD/m^3-day$ (6.5 ~ 9.0). During the start-up period, the low COD removal efficiency (20%) was caused by shock loading and instability in the reactor. It was mainly due to the high concentration amounts of ammonia nitrogen, which caused inhibitory and toxic effects to toward the anaerobic bacteria. In steady state, the UASB reactor showed a SCOD removal efficiency of 71% and a VS removal efficiency of 39%. The gas production and methane content were 1.3 L/day $(0.21\;m^3\;CH^4/kg$ COD removed) and 77%, respectively.

Study on Waterhammer Analysis (수격작용(워터햄머)의 해석에 관한 연구)

  • 남선우
    • Water for future
    • /
    • v.12 no.2
    • /
    • pp.49-55
    • /
    • 1979
  • The purpose of this study is to develope the computer program to compute the unsteady, transient flow conditions in a hydraulic system. The unstready flow condition may be brought about due to power failure to pump motors, pump start-up or modulation of control valve. The program was written specially for analyzing the water-hammer in the pumping system. The pumping system which can be simulated by the program can contain pipelines, tunnel, surge tanks, branched lines, reservoirs, dead end pipes and valve controls. The use of a computer program to analyze haydranlic transients is of great benifit to the designers of transmission main and distribution systems. Advantages include time savings, the ability to analyze complex piping systems, and increased accuracy. The author outlines a pogram developed for the above system.

  • PDF

Electric-optical Characteristics of Backlight Unit with LED Light Source in Low Temperature Condition

  • Han, Jeong-Min;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.93-96
    • /
    • 2007
  • LCD (liquid crystal display) industry is needed to goods of high reliability and is interested in products without harmful material. In this experiment, we made the LED backlight unit for Automotive-navigation. And for making this backlight unit we used to eight side emitting type white LEDs with 1 W high power of the lumileds company. We could know that this backlight unit releases to 6500 nit in 14 W power consumption and start up voltage time is under the 15ms in the ambient temperature $-20\;^{\circ}C$.

Development of Evaluation Method and Experimental Verification of a 300kW Small Engine Cogeneration System (300kW급 소형 엔진 열병합발전시스템의 평가기술 개발 및 실증시험)

  • Choi, Jae-Joon;Park, Hwa-Choon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.453-458
    • /
    • 2007
  • The importance of the evaluation and verification of small-size cogeneration system has been emphasized because there is no KS-code related to the small-size cogeneration system. The evaluation method of small-size engine cogeneration system was investigated by the reference of Japan evaluation code, JIS B-8122 and international standard organization, ISO-8528. Evaluation method was introduced such as start-test, rapid-load-up and rapid-load-down, etc. The evaluation method was applied to the 300kW small-size gas engine cogeneration system newly developed. The precise and strict evaluation and verification of the system will help the developing cogeneration system to optimum condition. It will also be a base document of KS-Code.

  • PDF

Development of On-line Displacement Monitoring System for High Temperature Steam Pipe of Fossil Power Plant (화력발전소 고온 증기배관 실시간 변위감시 시스템 개발)

  • Lee Young Shin;Hyun Jung Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.83-89
    • /
    • 2005
  • Most domestic fossil power plants have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe systems have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plants, 3-dimensional displacement measurement system was developed for the on-line monitoring. Displacement measurement system was developed with a use of a LVDT type sensor and two rotary encoder type sensors. This system was installed and operated on the real power plant successfully.

Fast VQ Encoding Algorithm (백터 양자화의 고속 부호화 알고리즘)

  • 채종길;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.4
    • /
    • pp.685-690
    • /
    • 1994
  • A problem associated with vector quantization(VQ) is the computational complexity incurred in searching for a codevector with the closet to a given input vector, where the complexity increases exponentionally with proportion to codebook size and then limits practical application. In this paper, a simple and fast, but efficient, VQ encoding algorithm is presented using a reference codevector as start codevector of premature exit condition, which eliminates distance claculation of unlikely codevectors. The algorithm is to find reference codevector having the possibility to be the nearest vector to input vector first and then to incorporate premature exit condition. The proposed algorithm needs only 10~15% of mathematical operations compared with the conventional full search VQ. Algorithm the number of additions and comparsions of the proposed algorithm is not reduced greatly, the number of multiplication is reduced up to 70~80% compared with other fast VQ encoding methods.

  • PDF

Characteristics of LPG Fuel Reforming using Plasma Technology (플라즈마를 이용한 LPG연료 개질 특성연구)

  • Kim, Changup
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • In this study, characteristics of reforming process of automotive liquefied petroleum gas (LPG) fuel using plasma reactor are investigated. Because plasma reformer technology has advantages of a fast start-up and wide fuel/oxidizer ratio of operation, and reactor size is smaller and more simple compared to typical combustor and catalytic reactor, plasma reforming is suitable to the on-board vehicle reformer. To evaluate the characteristics of the reforming process, parametric effect of $O_2/C$ ratios, reactant flow rate and metal form on the process were investigated. In the test of varying $O_2/C$ ratio from partial oxidation to stoichiometry combustion, conversion of LPG was increased but selectivity of $H_2$ decreased. The optimum condition of $O_2/C$ ratio for the highest $H_2$ yield was determined to be around 1.0 for 20~50 lpm, and 1.35 for 100 lpm. Specific energy density (SED) was major factor in reforming process and higher SED leads to higher $H_2$ yield. And metal form in the reformer increased $H_2$ yield of about 34 % as compared to the case of no metal form. The result can be a guide to map optimal condition of reforming process.

Excessive Condition Interpretation of a Exciter Circuit to Prevent Starting Failure of Large Synchronous Motor (대형 동기 전동기 기동실패방지를 위한 여자기회로 과도현상 해석)

  • Park, Jin-Hun;Cho, Ne-Su;Kwon, Woo-Hyen;Im, Soung-Hun;Yoon, Kyoung-Seop;Kim, Woo-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.739-740
    • /
    • 2006
  • According to the rapid growth of high speed and precise industry, the application of synchronous motor has been increased. In the application fields, the large synchronous motor is not a self-starting motor. The rotor is heavy and, from a dead stop, it is impossible to bring the rotor into magnetic lock with the rotating magnetic field for this reason, all synchronous motor have some kinds of starting device. A simple starter is another motor which brings the rotor up to approximately 96 percent of it synchronous speed. The starting motor is disconnected and the rotor locks in step with the rotating field. The more commony used starting method is to have the rotor to include a squirrel cage indution winding. This indution winding brings the rotor almost to synchronous speed as an induction motor. So, this paper describes excessive condition interpretation of a exciter circuit to prevent starting failure of large synchronous motor. the large synchronous motor needs safety of it in accordance with operating frequent start and stop. the operating Problem point of synchronous motor appears potential element damage of Exciter circuit because synchronous motor is caused synchronous separation. hence we eliminate it and improve starting toque.

  • PDF

An Analysis of Fatigue Characteristics of Upper limbs by Task Conditions Change (작업조건의 변화에 따른 상지의 피로 특성 분석)

  • Lee, Sang-Do;Sim, Jeong-Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.28 no.3
    • /
    • pp.75-86
    • /
    • 2005
  • To investigate the fatigue characteristic of upper limbs, this study analyzed RMS(root mean square) and MPF(mean power frequency) value between initial and terminal stages of each experiment condition. And the effect of intermittent endurance time was evaluated using the Borg's CR10 value that was measured for the parts of upper limb. According to the results of ANOVA on RMS value, there were significant difference on the %MVC about push, pull, and down force exertion. Particularly the ANOVA of up force exertion was significant difference on shoulder flexion, elbow flexion and rest time as well as %MVC. The results of ANOVA for MPF value were significant difference on the %MVC in regard of the push and up force exertion. In case of up force exertion, MPF value tended to shift low frequency at all of the experiment conditions. According to the analysis of duty cycle, RMS value considerably increased over 50% duty cycle and as the %MVC increased, the duty cycle affected the increase of RMS value. MPF value for up and down force exertion decreased at 33%, 50% and 67% duty cycle for all of %MVC. Borg CR10 value of hand and forearm were below the 3-point to the 40% of endurance time at 30%MVC and to the 20% of endurance time at 50%MVC with the exception of up force exertion. But Borg CR10 values of upper arm and shoulder at up force exertion were more than 3-point to the 20% of endurance time at 30%MVC and in the start point of endurance time at 50%MVC.