A Study on Cause Analysis of a Fire that Broke Out on a No-start Motor Vehicle (시동불능 자동차에서 발생한 화재의 원인 분석 연구)

  • Lee, Eui-Pyeong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.6
    • /
    • pp.92-99
    • /
    • 2012
  • It is often thought that because no-start motor vehicles cannot start an engine, a fire cannot occur for motor vehicle causes. However, although the engine cannot start up, some parts may be live with electricity if a battery is connected. If the parts have problems, a fire can occur. This study analyzed the causes of fires occurring when a motor vehicle was loaded onto a tow truck to service no-start. It is suggested that no-start motor vehicles should separate a battery terminal to prevent a fire. And this fire is related to automotive products liability.

A Study on the Characteristics in Single-Phase Line-Start Permanent Magnet Moter (단상 유도형 동기 전동기(LSPM)의 특성해석에 관한 연구)

  • Jung, Dae-Sung;Kim, Seung-Ju;Lee, Jin-Hun;Choi, Jae-Hak;Lee, Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.125-131
    • /
    • 2007
  • Electric motor efficient improvement from home appliance field is important to the effect reducing the energy consumption. But the electric motor design/analysis technology is still insufficient. Specially the electric motor design/analysis technology of satisfying characteristic of both the induction motor and the synchronous motor such as Line start permanent motor. Therefore the electric motor design/analysis technology is urgently demanded reliability. This paper proposes the sing1e-phase line-start permanent magnet motor to develop the motor it with be able to alternate the sing-phase induction motor it is a refrigerator compressor motor. The sing-phase induction motor is analyzed in the steady state. And we have a certification test to compare our single-phase line-start permanent magnet motor with the sing-phase induction motor. In order to improve the performance, the stator of the single-phase line-start permanent magnet motor is same as the stator of the sing-phase induction motor and changes the rotor form and has the permanent magnet. It used the Finite Element Method(FEM) which is widely used with electronic-magnetic field numerical analysis method.

Steady-State Characteristic Analysis of Single-Phase Line-Start Permanent Magnet Synchronous Motor (단상 영구자석형 유도동기기의 정상상태 특성해석)

  • Kang, Gyu-Hong;Nam, Hyuk;Hong, Jung-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.2
    • /
    • pp.53-60
    • /
    • 2003
  • This paper deals with steady-state analysis of a single-phase line-start permanent magnet synchronous motor. In order to analyze the steady-state characteristics, the asymmetric single-phase line-start synchronous motor is converted to the symmetric two-phase synchronous motor, that is, the asymmetric magnetic field is separated from the positive and the negative symmetric components using symmetrical-component theory. The analysis method of the synchronous motor on the d-q axis coordinates is used for the positive component and the equivalent circuit of the induction motor is applied for the negative component analysis. Moreover, d-q axis inductance considering current phase angle is applied to positive component analysis for precise characteristic analysis. In order to validate the proposed analysis method, the analysis results are compared with the experimental results.

Optimal Design for Starting -Torque of Line-Start Permanent Magnet Synchronous Motors (직립 기동 영구자석 동기전동기의 기동토크 최적화 설계)

  • Kim, Byong-Kuk;Moon, Ji-Woo;Kim, Mi-Jung;Lee, Byung-Jun;Cho, Yun-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1390-1396
    • /
    • 2007
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However, it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor. Finally this paper gives the comparison between the simulation results and the experimental results.

Analysis of Soft Start-up Characteristics of the Induction Motor Considering the Firing Angle (점호각을 고려한 유도전동기의 소프트 기동 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1007-1012
    • /
    • 2016
  • Induction motors are used widely in driving load of a fluid, such as a pump or a fan in the industry. Induction motor has been generated the voltage drop by the occurrence of a high current during startup. In addition, high start-up current can act as a mechanical stress on the shaft of the motor. So there is need a way to reduce the starting current. Soft start method is one of the many ways to reduce the starting current. This method uses silicon-controlled rectifiers(SCRs) for varying value of the voltage applied to the motor. There is a case for fixing or changing the thyristor firing angle to adjust the magnitude of the voltage. Starting power factor of induction motor is very low compared to the normal operation. Soft starting with the firing angle fixed needs to be considered a low power factor at startup. In this study, we compared the direct start characteristics and soft start characteristics considering the low power factor at the time of start-up. It was possible to confirm that the starting current and the voltage drop is present differently according to the firing angle.

Characteristic Analysis of Single Phase Line-start Permanent Magnet Synchronous Motor Considering Circuit Parameters (단상 직립 기동형 영구자석 동기기의 회로정수에 따른 특성 해석)

  • 강규홍;홍정표
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.262-270
    • /
    • 2003
  • In this paper, the characteristics of single-phase line-start permanent magnet synchronous motor driven by constant voltage are analyzed on d-q axis vector diagram and compared with that of current controlled motor. The coupled method of symmetrical coordinates and d-q axis voltage equation are applied to the analysis method like the analysis of single-phase induction motor. From the result of the analysis, it is seen that motors driven by constant voltage source have effects on not only the amplitude of current and torque but also current and current phase angle, so overall characteristics such as power factor and load angle are affected by circuit parameters. For precise analysis and design of single-phase line-start synchronous motor, its characteristics should be analyzed on d-q axis vector plan in consideration of the variation of circuit parameters.

Comparison of Dynamic Characteristics of the tine Start Permanent Magnet Motor and the Induction Motor

  • Yang, Byoung-Yull;Kwon, Byung-Il;Lee, Chul-Kyu;Woo, Kyung-Il;Kim, Byung-Taek
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.90-94
    • /
    • 2002
  • The line start permanent magnet (LSPM) motor has been developed facilitate to the design of the synchronous motor. The rotor of this motor is composed of interior permanent magnets and aluminum bars instead of rotor windings. It is difficult to predict the performance characteristics accurately, because many characteristics are produced by the aluminum rotor bars and the permanent magnets. Therefore, in this paper the dynamic characteristics of the LSPM motor are described and compared via the time-stepped finite element method with those of the cage-type induction motor to find the characteristics of the permanent magnets and the rotor bars in the LSPM motor.

Failure Prognostics of Start Motor Based on Machine Learning (머신러닝을 이용한 스타트 모터의 고장예지)

  • Ko, Do-Hyun;Choi, Wook-Hyun;Choi, Seong-Dae;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.85-91
    • /
    • 2021
  • In our daily life, artificial intelligence performs simple and complicated tasks like us, including operating mobile phones and working at homes and workplaces. Artificial intelligence is used in industrial technology for diagnosing various types of equipment using the machine learning technology. This study presents a fault mode effect analysis (FMEA) of start motors using machine learning and big data. Through multiple data collection, we observed that the primary failure of the start motor was caused by the melting of the magnetic switch inside the start motor causing it to fail. Long-short-term memory (LSTM) was used to diagnose the condition of the magnetic locations, and synthetic data were generated using the synthetic minority oversampling technique (SMOTE). This technique has the advantage of increasing the data accuracy. LSTM can also predict a start motor failure.

A Study on the Start-up Control for HDD Spindle Motors (HDD 스핀들 모터의 초기 구동 제어에 관한 연구)

  • Jeong, Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.10
    • /
    • pp.1065-1072
    • /
    • 2008
  • A HDD adopts a sensorless brushless DC (BLDC) motor as a spindle motor. Because there is no direct sensor measuring rotor position. open loop commutations with inductive sensing are used to increase the rotor speed up to a certain speed where the zero crossings of the back electromotive force (EMF) voltage are measurable. Therefore, successful open loop commutations are necessary for the stable start-up control of the spindle motors. In this paper, the time scale and the number of the open loop commutations are employed for design parameters to guarantee robustness to torque constant variation and initial rotor position. The design results are verified by experiments on a very low current start-up of the spindle motor with various environment. The experimental results show that the design results can decrease the start-up failure rate considerably.

Dynamic Characteristic Analysis of Line-Start Permanent Magnet Synchronous Motor (직립 기동 영구자석 동기전동기의 동특성 해석)

  • Kim, Byong-Kuk;Jo, Won-Yung;Lee, In-Jae;Moon, Ji-Woo;Kim, Mi-Jung;Lim, Seong-Hwan;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.185-187
    • /
    • 2006
  • The line-start permanent magnet synchronous motor has a high efficiency and an advantage in constant speed operation regardless of the effect of load variation. However it is difficult to predict the performance of characteristics accurately, because of the unbalanced starting torque with the initial starting position of the rotor and the generation of a break torque. In this paper the dynamic characteristics of the line-start permanent magnet synchronous motor are described and compared with those of the squirrel-cage induction motor through the simulation to find the characteristics of the permanent magnets and the rotor bars in the line-start permanent magnet synchronous motor.

  • PDF